A new monitoring method of cable tension of cable-stayed bridge—fiber Bragg grating method

被引:2
|
作者
张戌社
杜彦良
宁辰校
机构
[1] China
[2] College of Electric and Mechanical Engineering
[3] Hebei University of Science and Technology
[4] Shijiazhuang 050043
[5] Shijiazhuang 050054
[6] Shijiazhuang Railway Institute
[7] Structural Health Monitoring and Control Institute
关键词
bridge; cable tension; fiber Bragg grating;
D O I
暂无
中图分类号
U446.2 [桥梁观测与设备];
学科分类号
0814 ; 081406 ;
摘要
A new on-line monitoring method based on fiber Bragg grating(FBG) for cable tension of cable-stayed bridge was introduced. The major structure of sensing head using in the test of cable tension is elastic annular. The FBG is attached inflexibility to the exterior surface of annulus and form straight-through sensing head. Sensing head is installed between the anchor device and stow-board of funiculus holes of the cable-stayed bridge. Accompany with the change of the outside pressure, the Bragg center reflective wavelength of optical fiber grating changed correspondingly. According to this characteristic, through demodulating the Δλ, the value of the cable tension can be determined. The experiment results and the theory indicate that the test system has simple structure, good stability and linear,wide response capacity, and has no special request for tester, The measurement method for the test of cable tension is practical and effective.
引用
收藏
页码:261 / 263
页数:3
相关论文
共 50 条
  • [41] Intelligent health monitoring system for a cable-stayed bridge
    Sungkon Kim
    KSCE Journal of Civil Engineering, 2001, 5 (1) : 35 - 41
  • [42] Cable Health Monitoring System for Long-span Cable-stayed Bridge
    Gao Chao
    Li Xinke
    Guo Yongcai
    He Fuliang
    DISASTER ADVANCES, 2011, 4 : 130 - 135
  • [43] Health monitoring system for Dafosi cable-stayed bridge
    Zhu, Y
    Fu, YM
    Chen, WM
    Huang, SL
    Bennett, KD
    SMART STRUCTURES AND MATERIALS 2003: SMART SYSTEMS AND NONDESTRUCTIVE EVALUATION FOR CIVIL INFRASTRUCTURES, 2003, 5057 : 289 - 297
  • [44] Bearing Repair and Monitoring for Poyanghu Cable-Stayed Bridge
    Cheng, X. X.
    Ma, F. B.
    Chen, J. Q.
    Dong, B.
    Wu, G.
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [45] Measuring Methods of Cable Tension in Cable-Stayed Bridges
    Sun, Jiangbo
    Zhao, Zuozhou
    Zhao, Honghua
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-3, 2011, 295-297 : 1230 - +
  • [46] Rapid measurement method for cable tension of cable-stayed bridges using terrestrial laser scanning
    Zhou, Yin
    Zhang, Hong
    Hu, Xingyi
    Zhou, Jianting
    Zhu, Jinyu
    Xin, Jingzhou
    Yang, Jun
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2024, 39 (21) : 3269 - 3288
  • [47] Optimization on Stay Cable's Initial Tension Force for Extradosed Cable-Stayed Bridge
    Lin, Peng-Zhen
    ICMS2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION ICMS2010, VOL 3: MODELLING AND SIMULATION IN INDUSTRIAL APPLICATION, 2010, : 302 - 305
  • [48] Strain Monitoring of Main Beam of Cable-stayed Bridge Based on Weak Grating Array
    Liu, Zhiang
    Zheng, Jianxin
    Zhu, Hao
    Wang, Zichao
    Yang, Huadong
    SENSORS AND MATERIALS, 2022, 34 (04) : 1549 - 1558
  • [49] Clustering of Vehicular Cable Tension of Cable-Stayed Bridge Under Normal Operation Conditions
    Wei, Shiyin
    Li, Shunlong
    Li, Hui
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 3147 - 3154
  • [50] Innovative Method for the Construction of Cable-Stayed Bridges by Cable Crane
    Yu, Xiangmin
    Chen, Dewei
    STRUCTURAL ENGINEERING INTERNATIONAL, 2018, 28 (04) : 498 - 505