A new monitoring method of cable tension of cable-stayed bridge—fiber Bragg grating method

被引:2
|
作者
张戌社
杜彦良
宁辰校
机构
[1] China
[2] College of Electric and Mechanical Engineering
[3] Hebei University of Science and Technology
[4] Shijiazhuang 050043
[5] Shijiazhuang 050054
[6] Shijiazhuang Railway Institute
[7] Structural Health Monitoring and Control Institute
关键词
bridge; cable tension; fiber Bragg grating;
D O I
暂无
中图分类号
U446.2 [桥梁观测与设备];
学科分类号
0814 ; 081406 ;
摘要
A new on-line monitoring method based on fiber Bragg grating(FBG) for cable tension of cable-stayed bridge was introduced. The major structure of sensing head using in the test of cable tension is elastic annular. The FBG is attached inflexibility to the exterior surface of annulus and form straight-through sensing head. Sensing head is installed between the anchor device and stow-board of funiculus holes of the cable-stayed bridge. Accompany with the change of the outside pressure, the Bragg center reflective wavelength of optical fiber grating changed correspondingly. According to this characteristic, through demodulating the Δλ, the value of the cable tension can be determined. The experiment results and the theory indicate that the test system has simple structure, good stability and linear,wide response capacity, and has no special request for tester, The measurement method for the test of cable tension is practical and effective.
引用
收藏
页码:261 / 263
页数:3
相关论文
共 50 条
  • [1] A new monitoring method of cable tension of cable-stayed bridge—fiber bragg grating method
    Xu-she Zhang
    Yan-liang Du
    Chen-xiao Ning
    Journal of Central South University of Technology, 2005, 12 : 261 - 263
  • [2] A new monitoring method of cable tension of cable-stayed bridge-fiber Bragg grating method
    Zhang, XS
    Du, YL
    Ning, CX
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2005, 12 : 261 - 263
  • [3] A New Method for Measuring Cable Tension of Cable-Stayed Bridge-Cable Sag Method
    Ge J.
    Su M.
    Li W.
    Zhongguo Tiedao Kexue/China Railway Science, 2018, 39 (04): : 63 - 70
  • [4] Determination of cable tension on cable-stayed bridge
    Yao, Wen-Bin
    Zhang, Wei
    Shao, Qian-Jun
    Chinese Journal of Sensors and Actuators, 2004, 17 (03) : 484 - 487
  • [5] Assessment of cable tension condition based on optimum cable tension of cable-stayed bridge
    Institute of Architecture and Civil Engineering, Zhejiang University, Hangzhou 310027, China
    不详
    Zhejiang Daxue Xuebao (Gongxue Ban), 2006, 10 (1773-1777+1810):
  • [6] Influence of Cable Tension on the Mechanical Properties of Cable-stayed Bridge
    Li Xiaozhong
    Chen Xingchong
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2019, 13 (01) : 158 - 169
  • [7] Influence of cable tension on the mechanical properties of cable-stayed bridge
    Xiaozhong, Li
    Xingchong, Chen
    Jordan Journal of Civil Engineering, 2019, 13 (01): : 158 - 169
  • [8] The cable tension measurement and parameter identification for cable-stayed bridge
    Wang, W.
    Han, D.
    2001, South China University of Technology (29):
  • [9] Critical threshold value for monitoring & management of cable tension force in cable-stayed bridge
    Cho, HN
    Choi, YM
    Lee, SC
    Kang, KK
    Choi, MY
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 1977 - 1982
  • [10] Research on Estimation Method of Elastic Cable Stiffness of Cable-Stayed Bridge
    Xu, Li
    Liu, Kang
    Zhang, Chao
    Xu, Yang
    Huang, Qunjun
    2018 3RD INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE), 2018, : 64 - 68