Decoding and calibration method on focused plenoptic camera

被引:0
|
作者
Chunping Zhang [1 ]
Zhe Ji [1 ]
Qing Wang [1 ]
机构
[1] School of Computer Science, Northwestern Polytechnical University
基金
中国国家自然科学基金;
关键词
calibration; focused plenoptic camera; depth prior; intrinsic parameters;
D O I
暂无
中图分类号
TB852.1 [照相机];
学科分类号
0804 ;
摘要
The ability of light gathering of plenoptic camera opens up new opportunities for a wide range of computer vision applications. An efficient and accurate method to calibrate plenoptic camera is crucial for its development. This paper describes a 10-intrinsic-parameter model for focused plenoptic camera with misalignment. By exploiting the relationship between the raw image features and the depth–scale information in the scene, we propose to estimate the intrinsic parameters from raw images directly,with a parallel biplanar board which provides depth prior. The proposed method enables an accurate decoding of light field on both angular and positional information, and guarantees a unique solution for the 10 intrinsic parameters in geometry. Experiments on both simulation and real scene data validate the performance of the proposed calibration method.
引用
收藏
页码:57 / 69
页数:13
相关论文
共 50 条
  • [21] Fast projection based depth for focused plenoptic camera
    Hu, Guangchao
    Zhang, Yong
    Wang, Zhenjie
    PROCEEDINGS FIRST INTERNATIONAL CONFERENCE ON ELECTRONICS INSTRUMENTATION & INFORMATION SYSTEMS (EIIS 2017), 2017, : 759 - 762
  • [22] LIVE DEMONSTRATION: HIGH PERFORMANCE FOCUSED PLENOPTIC CAMERA
    Li, Chuanpu
    Sun, Xufu
    Jin, Xin
    Dai, Qionghai
    2019 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA & EXPO WORKSHOPS (ICMEW), 2019, : 610 - 610
  • [23] Artifacts Reduction in Image Rendering of the Focused Plenoptic Camera
    Liu, Peng
    Zhang, Rumin
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 1292 - 1297
  • [24] Plenoptic camera calibration based on microlens distortion modelling
    Darwish, Walid
    Bolsee, Quentin
    Munteanu, Adrian
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2019, 158 : 146 - 154
  • [25] Pattern-free Plenoptic 2.0 Camera Calibration
    Fachada, Sarah
    Bonatto, Daniele
    Losfeld, Armand
    Lafruit, Gauthier
    Teratani, Mehrdad
    2022 IEEE 24TH INTERNATIONAL WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING (MMSP), 2022,
  • [26] Simulation of calibration process in flame measurement by plenoptic camera
    Li, Tian-Jiao
    Sun, Jun
    Yuan, Yuan
    Xu, Chuan-Long
    Shuai, Yong
    Tan, He-Ping
    APPLIED THERMAL ENGINEERING, 2018, 135 : 179 - 187
  • [27] Three dimensional measurement with an electrically tunable focused plenoptic camera
    Lei, Yu
    Tong, Qing
    Xin, Zhaowei
    Wei, Dong
    Zhang, Xinyu
    Liao, Jing
    Wang, Haiwei
    Xie, Changsheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [28] Content-Based Depth Estimation in Focused Plenoptic Camera
    Atanassov, Kalin
    Goma, Sergio
    Ramachandra, Vikas
    Georgiev, Todor
    THREE-DIMENSIONAL IMAGING, INTERACTION, AND MEASUREMENT, 2011, 7864
  • [29] Decoding, Calibration and Rectification for Lenselet-Based Plenoptic Cameras
    Dansereau, Donald G.
    Pizarro, Oscar
    Williams, Stefan B.
    2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, : 1027 - 1034
  • [30] Optimal Design of Microlens Aperture Size for Focused Plenoptic Camera
    Luan, Yinsen
    Li, Donghu
    Lu, Lei
    Qiao, Lihong
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2020, 32 (20) : 1339 - 1342