Ozone reduction at Nafion modified Au electrode and the measurement of ozone concentration in highly resistive solutions

被引:0
|
作者
刘佩芳
文利柏
机构
[1] Department of Chemistry
[2] Wuhan University
[3] Hubei 430072
[4] China
关键词
Ozone; Nafion; microelectrode;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The mass transport and charge transfer kinetics of ozone reduction at Nafion coated Au electrodes were studied in 0.5 mol/L H2SO4 and highly resistive solutions such as distilled water and tap water. The diffusion coefficient and partition coefficient of ozone in Nafion coating are 1.78×10-6 cm2·s-1 and 2.75 at 25℃ (based on dry state thickness), respectively. The heterogeneous rate constants and Tafel slopes for ozone reduction at bare Au are 4.1×10-6 cm·s-1, 1.0×10-6 cm·s-1 and 181 mV, 207 mV in 0.5 mol/L H2SO4 and distilled water respectively and the corresponding values for Nafion coated Au are 5.5×10-6 cm·s-1, 1.1×10-6 cm·s-1 and 182 mV, 168 mV respectively. The Au microelectrode with 3 μm Nafion coating shows good linearity over the range 0-10 mmol/L ozone in distilled water with sensitivity 61 μA·ppm-1 ·cm-2, detection limit 10 ppb and 95% response time below 5 s at 25℃. The temperature coefficient in range of 11-30℃ is 1.3%.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 50 条
  • [21] Investigation of a Simplified Photometer Design for the Measurement of Ozone Gas Concentration
    Petani, Lisa
    Barth, Robert
    Wuehrl, Lorenz
    Sieber, Ingo
    Koker, Liane
    Reischl, Markus
    Gengenbach, Ulrich
    Pylatiuk, Christian
    2022 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES, IECBES, 2022, : 94 - 99
  • [22] MEASUREMENT OF OZONE CONCENTRATION FROM 55 TO 95 KM AT SUNSET
    MILLER, DE
    RYDER, P
    PLANETARY AND SPACE SCIENCE, 1973, 21 (06) : 963 - 970
  • [23] Measurement and Concentration Inversion of Ozone in Golmud by Laser Heterodyne Spectrometer
    Huang Jun
    Huang Yinbo
    Lu Xingji
    Cao Zhensong
    Qi Gang
    Yuan Zihao
    ACTA PHOTONICA SINICA, 2021, 50 (04)
  • [24] Investigation of Ozone Concentration Measurement by Visible Photo Absorption Method
    Teranishi, Kenji
    Shimada, Yoji
    Shimomura, Naoyuki
    Itoh, Haruo
    OZONE-SCIENCE & ENGINEERING, 2013, 35 (03) : 229 - 239
  • [25] MEASUREMENT OF OZONE CONCENTRATION FROM 65 TO 75 KM AT NIGHT
    DEJONCKHEERE, CG
    MILLER, DE
    PLANETARY AND SPACE SCIENCE, 1974, 22 (03) : 497 - 499
  • [26] THE MEASUREMENT OF OZONE CONCENTRATION FROM ITS HEAT OF DECOMPOSITION ON CATALYSTS
    PITSKHELAURI, EN
    POPOVICH, MP
    SABITOVA, LV
    SMIRNOVA, NN
    NUGAEV, TBK
    PEROV, SP
    FILIPPOV, YV
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 2 KHIMIYA, 1982, 23 (02): : 174 - 175
  • [27] Measurement of Aerial Ozone Concentration for the Prototype Atmospheric Plasma Jets
    Kim, Yunjung
    Yi, Seung-Ho
    Cho, Guangsup
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2017, 45 (08) : 2308 - 2313
  • [28] THE VERY SLOW DECOMPOSITION OF AQUEOUS OZONE IN HIGHLY BASIC SOLUTIONS
    NAKARESEISOON, S
    GORDON, G
    OZONE-SCIENCE & ENGINEERING, 1989, 11 (01) : 49 - 57
  • [29] Ag/Au Modified Nafion Coated Glassy Carbon Electrode for the Detection of Metronidazole
    Khanfar, Mohammad F.
    Al Absi, Naela
    Abu-Nameh, Eyad S. M.
    Saket, Munib M.
    Khorma, Natalie
    Al Daoud, Raya
    Alnuman, Nasim
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3265 - 3280
  • [30] Glassy carbon electrode modified with Nafion-Au colloids for clenbuterol electroanalysis
    Liu, Lijing
    Pan, Haibo
    Du, Min
    Xie, Wenqin
    Wang, Jian
    ELECTROCHIMICA ACTA, 2010, 55 (24) : 7240 - 7245