Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens

被引:0
|
作者
Xian-Hui Gong
机构
关键词
spherical aberration-free intraocular lens; sherical aberration; contrast sensitivity; cataract;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
AIM:To compare the visual and optical performance of eyes with different corneal spherical aberration(SA) implanted with spherical aberration-free intraocular lens(IOLs).· METHODS:Thirty-six patients with different corneal SA had phacoemulsification with implantation of spherical aberration-free IOLs.Patients were divided into 3 groups according to the value of preoperative corneal SA.Eyes with corneal SA <0.10μm were assigned to group A,those with 0.10 ≤corneal SA <0.20μm to Group B,and those with 0.20≤corneal SA <0.35μm to Group C.Best-corrected visual acuity(BCVA),contrast sensitivity,corneal SA,total ocular aberrations,and depth of focus were recorded 3 months postoperatively.Distance-corrected near and intermediate visual acuity was studied to measure depth of focus.· RESULTS:BCVA and contrast sensitivity were similar between groups.There were no significant differences in distance-corrected near or intermediate visual acuity.Corneal SA was similar before and 3 months after surgery in the 3 groups.With a 5.0mm pupil diameter,root mean square values for total ocular higher-order aberrations(HOAs) were lower in groups A and B than in group C.Total ocular SA was lower in group A than in groups B and C.SA was also lower in group B than in group C.Coma and trefoil were similar between the groups.· CONCLUSION:Implantation of spherical aberration-free IOLs in eyes with different corneal SA results in similar visual performance at BCVA,contrast sensitivity and depth of focus.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [31] Visual Performance of Pseudophakic Eyes Corrected for Spherical and Chromatic Aberrations with an Achromatic Intraocular Lens
    Weeber, Henk
    Pohl, Roland
    Mester, Ulrich
    Piers, Patricia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [32] Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes
    Bellucci, Roberto
    Morselli, Simonetta
    Pucci, Vincenzo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02): : 203 - 209
  • [33] Corneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery
    Al-Sayyari, Tarfah M.
    Fawzy, Samah M.
    Al-Saleh, Ahmed A.
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2014, 28 (04) : 274 - 280
  • [34] Effect of corneal asphericity and spherical aberration on intraocular lens power calculations Reply
    Savini, Giacomo
    Hoffer, Kenneth J.
    Barboni, Piero
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07): : 1554 - 1555
  • [35] Analysis of the Optical Quality of Spherical and Aspheric Intraocular Lenses in Simulated Nanophthalmic Eyes
    Cancado Trindade, Bruno Lovaglio
    Amaral, Felipe Tayer
    de Lima Monteiro, Davies William
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (03) : 193 - +
  • [36] Objective optical quality in eyes with customized selection of aspheric intraocular lens implantation
    Tan, Qing-Qing
    Lin, Jia
    Tian, Jing
    Liao, Xuan
    Lan, Chang-Jun
    BMC OPHTHALMOLOGY, 2019, 19 (1) : 152
  • [37] Clinical outcomes and postoperative intraocular optical quality with a microincision aberration-free aspheric intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Ortiz, Dolores
    Montalban, Raul
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1548 - 1554
  • [38] Objective optical quality in eyes with customized selection of aspheric intraocular lens implantation
    Qing-Qing Tan
    Jia Lin
    Jing Tian
    Xuan Liao
    Chang-Jun Lan
    BMC Ophthalmology, 19
  • [39] Clinical comparison of the optical performance of aspheric and spherical intraocular lenses
    van Gaalen, Kim W.
    Koopmans, Steven A.
    Jansonius, Nomdo M.
    Kooijman, Aart C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01): : 34 - 43
  • [40] Contrast Sensitivity and Spherical Aberration in Eyes Implanted with AcrySof IQ and AcrySof Natural Intraocular Lens: the Results of a Meta-Analysis
    Liu, Jianping
    Zhao, Jiangyue
    Ma, Liwei
    Liu, Guangcong
    Wu, Di
    Zhang, Jinsong
    PLOS ONE, 2013, 8 (10):