Fuzzy control method to minimize the needle deflection during needle insertion therapy

被引:0
|
作者
张少华 [1 ]
金鑫 [1 ]
叶鑫 [1 ]
张之敬 [1 ]
刘冰冰 [1 ]
邓勇军 [1 ]
机构
[1] School of Mechanical Engineering,Beijing Institute of Technology
关键词
needle insertion; needle deflection; fuzzy control; force feedback;
D O I
10.15918/j.jbit1004-0579.2013.04.012
中图分类号
TP242 [机器人];
学科分类号
1111 ;
摘要
A fuzzy control algorithm is adopted to help the needle hit the target more accurately.The experimental setup for the needle insertion is built up to validate the algorithm.How the forces during the insertion make the needle deflect away from the planned path is given,and the normal method correcting the deflection is obtained accordingly.Because the normal method cannot perform well for correction,a fuzzy controller is established.The input module,output module,fuzzification module,defuzzification module and inference engine for the controller are given respectively according to the fuzzy theory.Our experimental results show that the fuzzy controlling system presenting in the paper can better eliminate the deflection.
引用
收藏
页码:477 / 482
页数:6
相关论文
共 50 条
  • [41] Control and Experimental Study of Flexible Needle Insertion Mechanism
    Zhang, Yong-de
    Chen, Hao
    Zhao, Yan-jiang
    Wang, Jin-you
    WMSCI 2011: 15TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL I, 2011, : 228 - 232
  • [42] Energy shaping nonlinear control of underactuated needle insertion
    Franco, Enrico
    Donaire, Alejandro
    CONTROL ENGINEERING PRACTICE, 2022, 128
  • [43] Adaptive energy shaping control of robotic needle insertion
    Franco, Enrico
    Brown, Timothy
    Astolfi, Alessandro
    Rodriguez y Baena, Ferdinando
    MECHANISM AND MACHINE THEORY, 2021, 155
  • [44] CONSTANT SITE (BUTTONHOLE) METHOD OF NEEDLE INSERTION FOR HEMODIALYSIS
    TWARDOWSKI, ZJ
    DIALYSIS & TRANSPLANTATION, 1995, 24 (10) : 559 - &
  • [45] Constant Site (Buttonhole) Method of Needle Insertion for Hemodialysis
    Twardowski, Zbylut J.
    DIALYSIS & TRANSPLANTATION, 2011, 40 (10) : 441 - 443
  • [46] A local constraint method for needle insertion modeling and simulation
    Wang L.
    Hirai S.
    HAVE 2011 - IEEE International Symposium on Haptic Audio-Visual Environments and Games, Proceedings, 2011, : 39 - 44
  • [47] Effects of velocity modulation during surgical needle insertion
    Podder, T. K.
    Clark, D. P.
    Fuller, D.
    Sherman, J.
    Ng, W. S.
    Liao, L.
    Rubens, D. J.
    Strang, J. G.
    Messing, E. M.
    Zhang, Y. D.
    Yu, Y.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5766 - 5770
  • [48] Modelling needle forces during insertion into soft tissue
    Cheng, Zhuoqi
    Chauhan, Manish
    Davies, Brian L.
    Caldwell, Darwin G.
    Mattos, Leonardo S.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 4840 - 4844
  • [49] 'Needle adhesiolysis' prior to port insertion during laparoscopy
    Yardley, Iain E.
    Morecroft, James A.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (01) : 77 - 78
  • [50] Shape Determination During Needle Insertion With Curvature Measurements
    Kim, Jin Seob
    Guo, Jiangzhen
    Chatrasingh, Maria
    Kim, Sungmin
    Iordachita, Iulian
    2017 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2017, : 201 - 208