Dual Torch Plasma Arc Furnace for Medical Waste Treatment

被引:0
|
作者
刘斌 [1 ]
M.KIKUCHI [1 ]
李和平 [2 ]
T.IWAO [3 ]
T.INABA [1 ]
机构
[1] Graduate School of Science and Engineering,Chuo University,Tokyo 112-8551,Japan
[2] Department of Engineering Physics,Tsinghua University,Beijing 100084,China
[3] Faculty of Engineering,Musashi Institute of Technology,Tokyo 158-8557,Japan
关键词
dual torch; plasma arc furnace; medical waste;
D O I
暂无
中图分类号
O539 [等离子体物理的应用];
学科分类号
摘要
In this paper,characteristics of a dual torch plasma arc used for hazardous wastetreatment and operated at atmospheric pressure are studied,and also compared with those of themulti-torch plasma arc and the single torch plasma arc.The dual torch plasma arc is generatedbetween the cathode and anode with argon as the working gas.The temperature distributionsof the plasma arc are measured using a spectroscope and line pair method with the assumptionof local thermodynamic equilibrium (LTE) for the DC arc current I=100 A and argon flow rateQ = 15 slpm.The measurements show that the temperatures of the dual torch arc plasma in theregions near the cathode,the anode and the center point are 10,000 K,11,000 K and 9,000 K,respectively.And the high temperature region of the multi torch plasma arc is of double or muchwider size than that of a conventional dual torch plasma arc and single plasma torch.Based onthe preceding studies,a dual torch plasma arc furnace is developed in this study.The measuredgas temperature at the center region of the argon arc is about 11,000 K for the case of I = 200 Aand Q=30 slpm operated in atmosphere.
引用
收藏
页码:709 / 712
页数:4
相关论文
共 50 条
  • [11] Arc Plasma Torch Modeling
    Trelles, J. P.
    Chazelas, C.
    Vardelle, A.
    Heberlein, J. V. R.
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2009, 18 (5-6) : 728 - 752
  • [12] Arc plasma torch modeling
    Szafranski, A
    Kaminska, A
    Bialek, A
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS IV, 2006, 6159
  • [13] Magnetohydrodynamic Simulation of Plasma Torch Used for Waste Treatment
    S. Elaissi
    I. Alshunaifi
    H. Alyousef
    I. Ghiloufi
    Plasma Physics Reports, 2021, 47 : 704 - 714
  • [14] Detoxifying PCDD/Fs and heavy metals in fly ash from medical waste incinerators with a DCdouble arc plasma torch
    Xinchao Pan
    Jianhua Yan
    Zhengmiao Xie
    Journal of Environmental Sciences, 2013, (07) : 1362 - 1367
  • [15] Detoxifying PCDD/Fs and heavy metals in fly ash from medical waste incinerators with a DCdouble arc plasma torch
    Xinchao Pan
    Jianhua Yan
    Zhengmiao Xie
    Journal of Environmental Sciences, 2013, 25 (07) : 1362 - 1367
  • [16] Design and Performance Evaluation of Integrating the Waste Heat Recovery System (WHRS) for a Silicon Arc Furnace with Plasma Gasification for Medical Waste
    Dong, Yuehong
    Wei, Lai
    Wang, Sheng
    Pan, Peiyuan
    Chen, Heng
    ENTROPY, 2023, 25 (04)
  • [17] Fluctuation of arc plasma in arc plasma torch with multiple cathodes
    张泽龙
    王城
    孙强
    夏维东
    Chinese Physics B, 2019, (09) : 286 - 291
  • [18] Fluctuation of arc plasma in arc plasma torch with multiple cathodes
    Zhang, Zelong
    Wang, Cheng
    Sun, Qiang
    Xia, Weidong
    CHINESE PHYSICS B, 2019, 28 (09)
  • [19] Arc plasma jets of a nontransferred plasma torch
    Kang, KD
    Hong, SH
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1996, 24 (01) : 89 - 90
  • [20] DC Arc Plasma Furnace Melting of Waste Incinerator Fly Ash
    陈明周
    孟月东
    施嘉标
    匡静安
    倪国华
    刘卫
    江贻满
    Plasma Science and Technology, 2009, (01) : 62 - 65