Porcine acute liver failure model established by two-phase surgery and treated with hollow fiber bioartificial liver support system

被引:0
|
作者
Yi Gao
机构
关键词
Acute liver failure; Animal model; Bioartificial liver; Micro-capsulized activated carbon adsorbing; Porcine hepatocyte;
D O I
暂无
中图分类号
R575.3 [肝功能衰竭];
学科分类号
1002 ; 100201 ;
摘要
AIM: To establish a highly reproducible animal model of acute liver failure (ALF), for assessing the effect of bioartificial liver support system (BALSS). METHODS: A two-phase complete liver devascularization procedure was performed in eight loco-hybrid pigs. Blood biochemical index and liver biopsy were studied every 2 h after surgery, and survival time was recorded. The BALSS constructed with high volume recirculating technique was a hollow fiber circulating system consisting of a hepatocyte reactor-hollow fiber module inoculated with microcarrieradhering hepatocytes, and a double pump, heparinized, thermostabilized, micro-capsulized activated carbonadsorbing plasmapheresis system. Twelve pigs undergoing two-phase surgery were randomized into: control group (perfused without hepatocytes, n=6) and treatment group (perfused with hepatocytes, n=6). Intergroup liver biochemical indexes, survival time, and liver pathological changes were analyzed at regular intervals. RESULTS: Two-phase surgery was performed in all the experimental pigs, and there was no obvious difference between their biochemical indexes. After 3 h of phase II surgery, ammonia (Amm) increased to (269±37) |umol/L. After 5 h of the surgery, fibrinogen (Fib) decreased to (1.5±0.2) g/L. After 7 h of the surgery, ALT, AST, Tbil and PT were (7.6±1.8) nka/L, (40±5) nka/L, (55±8) nmol/L and (17.5±1.7) nka/L respectively. After 9 h of surgery, ALB and Cr were (27±4) g/L and (87±9) nmol/L. After 13 h of surgery, BUN was (3.5±0.9) μmol/L. All the above values were different from those determined before surgery. Survival time of pigs averaged 13.5±1.4 h. ALF pigs in the other group were treated with BALSS. The comparison analysis between the treated and control animals showed the changes of Tbil, PT, Alb, BUN, Cr, Fib, and Amm (P<0.01), but there was no change of ALT and AST. The survival time was statistically different (P<0.01), and there was no significant difference in histological changes. CONCLUSION: The porcine ALF model established by two-phase devascularized surgery is valid and reproducible. The hollow fiber BALSS can meet the needs of life support and is effective in treating ALF.
引用
收藏
页码:5468 / 5474
页数:7
相关论文
共 50 条
  • [41] A bioartificial transgenic porcine whole liver expressing human proteins alleviates acute liver failure in pigs
    Xue, Wei-Song
    Zhang, Hao-Jie
    Ke, Jing-Jing
    Fu, Yu
    Peng, Qing
    Li, Li
    Gao, Yi
    Zhong, Ke-Bo
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2023, 22 (03) : 270 - 281
  • [42] Evaluation of an extracorporeal liver support system in an experimental model of acute liver failure
    Kostopanagiotou, G
    Arkadopoulos, N
    Theodoraki, K
    Athanassiou, L
    Papalois, A
    Prahalias, A
    Smyrniotis, V
    Papadimitriou, J
    9TH EUROPEAN CONGRESS ON INTENSIVE CARE MEDICINE, 1996, : 791 - 795
  • [43] A bioartificial transgenic porcine whole liver expressing human proteins alleviates acute liver failure in pigs
    Wei-Song Xue
    Hao-Jie Zhang
    Jing-Jing Ke
    Yu Fu
    Qing Peng
    Li Li
    Yi Gao
    Ke-Bo Zhong
    Hepatobiliary&PancreaticDiseasesInternational, 2023, 22 (03) : 270 - 281
  • [44] A biodialysis system for liver support tested in a porcine hepatic failure model
    Sheil, AGR
    Sun, JH
    Wang, LS
    Rao, N
    Mears, DC
    Wang, CM
    Woodman, K
    Johnston, B
    Watson, J
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 2000, 70 (02): : 127 - 131
  • [45] Temporary neurological improvement in a patient with acute or chronic liver failure treated with a bioartificial liver device
    Donini, A
    Baccarani, U
    Risaliti, A
    Degrassi, A
    Bresadola, F
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2000, 95 (04): : 1102 - 1104
  • [46] Is PERV transfer across hollow fiber membranes relevant to bioartificial liver model?
    Falasca, E
    Baccarani, U
    Pipan, C
    Degrassi, A
    Donini, A
    TRANSPLANTATION, 2000, 69 (08) : 1755 - 1755
  • [47] Acute Liver Failure in Porcine Hepatectomy Model
    Chen, H.
    Joo, D. J.
    Shaheen, M.
    Li, Y.
    Amiot, B.
    Nyberg, S.
    TRANSPLANTATION, 2017, 101 (05) : 26 - 26
  • [48] A reliable graded acute liver failure model in rats: treatment with internal bioartificial liver
    Qing-Xiang Xu
    Hepatobiliary Surgery Institute of Nanjing
    Biochemistry Department of Nanjing University
    Hepatobiliary & Pancreatic Diseases International, 2004, (02) : 254 - 258
  • [49] A bioartificial liver support system using primary hepatocytes:: A preclinical study in a new porcine hepatectomy model
    Frühauf, NR
    Oldhafer, KJ
    Höltje, M
    Kaiser, GM
    Frühauf, JH
    Stavrou, GA
    Bader, A
    Broelsch, CE
    SURGERY, 2004, 136 (01) : 47 - 56
  • [50] Prognosis of acute-on-chronic liver failure patients treated with artificial liver support system
    Zhou, Pi-Qi
    Zheng, Shao-Ping
    Yu, Min
    He, Sheng-Song
    Weng, Zhi-Hong
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (32) : 9614 - 9622