Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck

被引:0
|
作者
van der Hulst, Hedda J. [1 ,2 ,5 ]
Braun, Loes [1 ]
Westerink, Bram [1 ]
Agrotis, Georgios [1 ,6 ]
ter Beek, Leon C. [3 ]
Tissier, Renaud [4 ]
Ahmadian, Milad [1 ,2 ,7 ]
Martens, Roland M. [8 ]
Casselman, Jan W. [10 ,11 ]
Beets-Tan, Regina G. H. [1 ,5 ,12 ]
van den Brekel, Michiel W. M. [2 ,9 ]
Castelijns, Jonas A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Clin Phys, Amsterdam, Netherlands
[4] Netherlands Canc Inst, Biostat Unit, Amsterdam, Netherlands
[5] Univ Maastricht, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[6] Univ Hosp Larissa, Dept Neurosurg, Thessaly, Greece
[7] Univ Amsterdam, Amsterdam Ctr Language & Commun, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam Univ, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[9] Vrije Univ Amsterdam, Amsterdam Univ, Dept Oral & Maxillofacial Surg, Med Ctr, Amsterdam, Netherlands
[10] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[11] Arizona St Lucas Gent, Dept Radiol, Ghent, Belgium
[12] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
关键词
COEFFICIENT; LESIONS; DWI; ACCURACY;
D O I
10.3174/ajnr.A8529
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI using single-shot echo-planar imaging (DWI-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, split acquisition of fast spin-echo signals for diffusion imaging (DW-SPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DWI-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3T head and neck MRI protocol with DWI-EPI. Retrospective analysis was conducted on 2 subgroups: first benign or malignant lesions, and second, posttreatment SCC recurrence. In both subgroups, image quality and distortion were scored by 2 independent radiologists, blinded to the DWI technique and evaluated using mixed-effect linear models. Lesion ADC values were assessed with interclass correlation and Bland-Altman analyses. The delineation geometric similarity of DWI to T1-weighted postcontrast MRI was evaluated using the DSC before and after registration. Recurrence in posttreatment SCC scans was evaluated by the same 2 radiologists blinded to the DWI technique. Recurrence detection rates were then compared between DW-SPLICE and DWI-EPI using mixed logistic regression at 6 months and 1 year postscan follow-up data. RESULTS: From August 2020 to January 2022, fifty-five benign or malignant lesion scans (55 patients) and 74 posttreatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DWI-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DWI-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the head and neck. Consistent use of 1 method for follow-up is advised, because ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice.
引用
收藏
页码:774 / 783
页数:10
相关论文
共 50 条
  • [31] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467
  • [32] Diffusion-Weighted MR Imaging in Head and Neck Cancer: Comparison between Half-Fourier Acquired Single-Shot Turbo Spin-Echo and EPI Techniques
    Verhappen, M. H.
    Pouwels, P. J. W.
    Ljumanovic, R.
    van der Putten, L.
    Knol, D. L.
    De Bree, R.
    Castelijns, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) : 1239 - 1246
  • [33] Single-Shot Turbo Spin-Echo Diffusion-Weighted Imaging for Retinoblastoma: Initial Experience
    de Graaf, P.
    Pouwels, P. J. W.
    Rodjan, F.
    Moll, A. C.
    Imhof, S. M.
    Knol, D. L.
    Sanchez, E.
    van der Valk, P.
    Castelijns, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) : 110 - 118
  • [34] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [35] Partial k-space reconstruction in single-shot diffusion-weighted echo-planar imaging
    Storey, Pippa
    Frigo, Fred J.
    Hinks, R. Scott
    Mock, Bryan J.
    Collick, Bruce D.
    Baker, Nicole
    Marmurek, Jonathan
    Graham, Simon J.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 614 - 619
  • [36] Intravoxel incoherent motion diffusion-weighted imaging in nasopharyngeal carcinoma: comparison of the turbo spin-echo and echo-planar imaging techniques
    Liu, Yuan
    Hu, Liu
    Qian, Lijuan
    Chen, Manman
    Xu, Si
    Sun, Peng
    Huang, Jing
    Lei, Ziqiao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9101 - 9111
  • [37] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340
  • [38] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    He An
    Xiaodong Ma
    Ziyi Pan
    Hua Guo
    Elaine Yuen Phin Lee
    European Radiology, 2020, 30 : 1876 - 1884
  • [39] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [40] Head and neck lesions: Characterization with diffusion-weighted echo-planar MR imaging
    Wang, JC
    Takashima, S
    Takayama, F
    Kawakami, H
    Saito, A
    Matsushita, T
    Momose, M
    Ishiyama, T
    RADIOLOGY, 2001, 220 (03) : 621 - 630