Unidirectional Frequency-Steerable Acoustic Transducer for guided ultrasonic wave damage imaging

被引:0
|
作者
Mohammadgholiha, Masoud [1 ]
Moll, Jochen [2 ,3 ]
Tschoke, Kilian [4 ]
Kruska, Carsten [4 ]
Gebhardt, Sylvia E. [4 ]
De Marchi, Luca [1 ]
机构
[1] Univ Bologna, Dept Elect Elect & Informat Engn, Bologna, Italy
[2] Goethe Univ, Dept Phys, Frankfurt, Germany
[3] Univ Siegen, Dept Mech Engn, Siegen, Germany
[4] Fraunhofer Inst Ceram Technol & Syst IKTS, Fraunhofer IKTS, Dresden, Germany
关键词
Structural health monitoring; Guided waves; Frequency Steerable Acoustic Transducers; Unidirectional generation; Phased array; WAFER ACTIVE SENSORS; EXCITATION; PLATE; LOCALIZATION; ARRAYS;
D O I
10.1016/j.ymssp.2025.112505
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonic guided waves (GWs) are extensively utilized in nondestructive evaluation and structural health monitoring (SHM) fields. Typically, phased-array GW-based inspections consist of numerous piezoelectric transducers permanently attached to the monitored structure. However, these systems face challenges such as bulky hardware, a large number of transducers and cables for individual element control, complex circuitry and signal processing, high power consumption, and consequently high integration costs. To overcome these limitations, shaped transducers featuring inherent beam steering properties, such as Frequency Steerable Acoustic Transducers (FSATs) can be adopted. FSATs exploit a frequency-dependent spatial filtering effect, which is achieved by properly patterning the electrodes of the piezoelectric transducers. This allows the direction of the generated or sensed wave to be controlled simply by the spectral content of the actuated or received signal, a process so-called "In-sensor" signal processing. Initial generations of FSATs face a 180 degrees ambiguity, where waves are simultaneously generated or sensed in both forward and backward directions. This could lead to uncertainty in defect localization or generate undesirable reflections. In this work, a novel unidirectional FSAT is proposed to eliminate this ambiguity through a new design strategy for unidirectional wave generation and sensing, addressed in the wavenumber domain. Finite element simulations and experimental testing on an aluminum plate validated the proposed frequency-dependent unidirectional beam steering concept. Additionally, the transducer was successfully used in pulse-echo mode for damage imaging, demonstrating 98% localization accuracy. The proposed embedded system can substantially reduce the software and hardware requirements of conventional solutions, paving the way for the development of permanent inspection systems.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Dynamic Mode Tuning of Ultrasonic Guided Wave Using an Array Transducer
    Kim, Young H.
    Song, Sung-Jin
    Park, Joon-Soo
    Kim, Jae-Hee
    Eom, Heung-Sup
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2005, 25 (01) : 20 - 26
  • [32] Development of Ultrasonic Guided Wave Transducer for Monitoring of High Temperature Pipelines
    Dhutti, Anurag
    Tumin, Saiful Asmin
    Balachandran, Wamadeva
    Kanfoud, Jamil
    Gan, Tat-Hean
    SENSORS, 2019, 19 (24)
  • [33] Research on Transducer and Frequency of Ultrasonic Guided Waves in Urban Pipe Inspection
    Sun Li-ying
    Yang Xiao-dong
    Li Yi-bo
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 2699 - +
  • [34] Line-focusing of ultrasonic SV wave by electromagnetic acoustic transducer
    Ogi, H
    Hirao, M
    Ohtani, T
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (05): : 2411 - 2415
  • [35] Development of an electromagnetic acoustic transducer (EMAT) for the noncontact excitation of guided ultrasonic waves
    Fromme, P.
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2015, 2015, 9438
  • [36] Focused high frequency needle transducer for ultrasonic imaging and trapping
    Hsu, Hsiu-Sheng
    Zheng, Fan
    Li, Ying
    Lee, Changyang
    Zhou, Qifa
    Shung, K. Kirk
    APPLIED PHYSICS LETTERS, 2012, 101 (02)
  • [37] Single-phase unidirectional surface acoustic wave transducer using Cu electrode
    Nakagomi, S
    Asano, H
    Tanaka, H
    Omori, T
    Hashimoto, K
    Yamaguchi, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2003, 42 (5B): : 3152 - 3156
  • [38] TRANSDUCTION CHARACTERISTICS OF A SURFACE-ACOUSTIC-WAVE UNIDIRECTIONAL INTERDIGITAL TRANSDUCER WITH LIQUID LOADING
    TAKEUCHI, M
    YAMANOUCHI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (5B): : 2384 - 2387
  • [39] Single-phase unidirectional surface acoustic wave transducer using Cu electrode
    Nakagomi, S. (sho-n@usl.te.chiba-u.ac.jp), 1600, Japan Society of Applied Physics (42):
  • [40] A frequency selective acoustic transducer for directional Lamb wave sensing
    Senesi, Matteo
    Ruzzene, Massimo
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (04): : 1899 - 1907