Long-Term Outcomes After Aortic Valve Replacement for Aortic Valve Regurgitation Importance of Left Ventricular End-Systolic Diameter

被引:1
|
作者
Hachiro, Kohei [1 ]
Takashima, Noriyuki [1 ]
Suzuki, Tomoaki [1 ]
机构
[1] Shiga Univ Med Sci, Dept Surg, Div Cardiovasc Surg, Setatsukinowa Cho, Otsu 5202192, Japan
关键词
Aortic valve regurgitation; Aortic valve replacement; Left ventricular end-systolic diameter; HYPERTROPHY; MORTALITY; FIBROSIS;
D O I
10.1253/circj.CJ-24-0081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We determined the left ventricular end-systolic diameter (LVDs) cut-off value for risk of major adverse cardiac and cerebrovascular events (MACCE) in Japanese asymptomatic or mildly symptomatic patients undergoing aortic valve replacement (AVR) for aortic valve regurgitation (AR), and investigated the effect of left ventricular dilation on long-term postoperative outcomes. Methods and Results: The 168 patients who underwent surgical AVR for AR at Shiga University of Medical Science between January 2002 and December 2022 were included in this study. Receiver operating characteristic curve analysis showed that the cut-off value of preoperative LVDs for the incidence of MACCE was 42.8 mm (area under the curve 0.616). Postoperative outcomes were compared between patients with preoperative LVDs >42.8 mm (n=77) and those with preoperative LVDs <= 42.8mm (n=91) using propensity score matching. The 10-year estimated rates of freedom from MACCE in those with LVDs >42.8 and <= 42.8 mm were 59.9% and 85.7%, respectively; the curves differed significantly (P=0.004). In multivariable Cox proportional hazard regression analyses, preoperative LVDs >42.8 mm was an independent predictor of MACCE (hazard ratio 2.485; 95% confidence interval 1.239-4.984; P=0.010). Conclusions: Preoperative LVDs >42.8 mm is associated with an increased risk of MACCE in Japanese patients undergoing AVR for AR.
引用
收藏
页码:1955 / 1961
页数:7
相关论文
共 50 条
  • [31] REVERSIBILITY OF THE LEFT-VENTRICULAR FUNCTION AFTER AORTIC-VALVE REPLACEMENT FOR AORTIC REGURGITATION
    KAWACHI, K
    KAWASHIMA, Y
    KITAMURA, S
    MORI, T
    NAKANO, S
    OYAMA, C
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1983, 47 (06): : 635 - 640
  • [32] AORTIC REGURGITATION NEGATIVELY AFFECTS LEFT VENTRICULAR MECHANICS AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Sato, Kimi
    Kumar, Arnav
    Jones, Brandon
    Mick, Stephanie
    Krishnaswamy, Amar
    Grimm, Richard
    Desai, Milind
    Griffin, Brian
    Rodriguez, L. Leonardo
    Kapadia, Samir
    Popovic, Zoran
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1631 - 1631
  • [33] MECHANISMS FOR LEFT-VENTRICULAR SYSTOLIC DYSFUNCTION IN AORTIC REGURGITATION - IMPORTANCE FOR PREDICTING THE FUNCTIONAL-RESPONSE TO AORTIC-VALVE REPLACEMENT
    STARLING, MR
    KIRSH, MM
    MONTGOMERY, DG
    GROSS, MD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (04) : 887 - 897
  • [34] Indexed Left Ventricular Dimensions Best Predict Survival After Aortic Valve Replacement in Patients With Aortic Valve Regurgitation
    Brown, Morgan L.
    Schaff, Hartzell V.
    Suri, Rakesh M.
    Zhuo, Li
    Sundt, Thoralf M.
    Dearani, Joseph A.
    Daly, Richard C.
    Orszulak, Thomas A.
    ANNALS OF THORACIC SURGERY, 2009, 87 (04): : 1170 - 1176
  • [35] Regression in Left Ventricular Mass after Aortic Valve Replacement for Chronic Aortic Regurgitation Is Unrelated to Prosthetic Valve Size
    Brown, M. L.
    Hartzell, V. Schaff
    Suri, R. M.
    Zhou, L.
    Sundt, T. M.
    Dearani, J. A.
    Enriquez-Sarano, M.
    CARDIOLOGY, 2010, 115 (04) : 255 - 255
  • [36] Regression in Left Ventricular Mass After Aortic Valve Replacement for Chronic Aortic Regurgitation is Unrelated to Prosthetic Valve Size
    Brown, Morgan L.
    Schaff, Hartzell V.
    Suri, Rakesh M.
    Li, Zhuo
    Sundt, Thoralf M., III
    Dearani, Joseph A.
    Daly, Richard C.
    Sarano, Maurice E.
    Orszulak, Thomas A.
    CIRCULATION, 2009, 120 (18) : S898 - S898
  • [37] Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size
    Brown, Morgan L.
    Schaff, Hartzell V.
    Suri, Rakesh M.
    Li, Zhuo
    Sundt, Thoralf M.
    Dearani, Joseph A.
    Enriquez-Sarano, Maurice
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (02): : E5 - E9
  • [38] Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis Implications for Long-Term Outcomes
    Beneduce, Alessandro
    Pagnesi, Matteo
    Ancona, Marco Bruno
    Ferri, Luca Angelo
    Montorfano, Matteo
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (15) : 1833 - 1834
  • [39] Long-term outcomes of valve-in-valve transcatheter aortic valve implantation for degenerate homograft aortic valve replacement
    Duncan, Alison
    Davies, Allan
    Quarto, Cesare
    Davies, Simon
    EUROINTERVENTION, 2020, 16 (09) : E760 - E762
  • [40] Impact of right and left ventricular systolic dysfunction on perioperative outcome and long-term survival after transcatheter aortic valve replacement
    Griese, Daniel P.
    Kerber, Sebastian
    Barth, Sebastian
    Diegeler, Anno
    Babin-Ebell, Joerg
    Reents, Wilko
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2017, 30 (03) : 217 - 225