Cerebral Embolic Protection Devices in Transcatheter Aortic Valve Implantation: Meta-Analysis With Trial Sequential Analysis

被引:0
|
作者
Warraich, Nav [1 ,2 ]
Sa, Michel Pompeu [3 ]
Jacquemyn, Xander [4 ]
Kuno, Toshiki [5 ]
Serna-Gallegos, Derek [1 ,2 ]
Sultan, Ibrahim [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Cardiothorac Surg, Div Cardiac Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, UPMC Heart & Vasc Inst, Med Ctr, Pittsburgh, PA USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiac Surg, Boston, MA USA
[4] Katholieke Univ Leuven, Leuven, Belgium
[5] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiol, Boston, MA USA
来源
关键词
cerebral embolic protection devices; meta-analysis; TAVI; trial sequential analysis; RANDOMIZED EVALUATION; REPLACEMENT; LESIONS;
D O I
10.1161/JAHA.124.038869
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We aimed to reevaluate randomized controlled trial data on outcomes of cerebral embolic protection device use during transcatheter aortic valve implantation. A conventional meta-analysis followed by trial sequential analysis was conducted to evaluate the strength of the current evidence.Methods and Results Databases were searched for randomized controlled trials. Primary outcomes included all stroke, disabling stroke, and all-cause mortality. Conventional study-level meta-analysis was performed using random-effects modeling. Trial sequential analysis was conducted to generate adjusted significance boundaries, futility boundaries, and the required information size considering a type I error of 5% and a power of 90%. Seven trials were included with a total of 4031 patients, of whom 2171 were treated with a device and 1860 were not. Conventional meta-analysis showed no significant difference in all stroke (relative risk [RR], 0.85 [95% CI, 0.61-1.18]; P=0.339) and disabling stroke (RR, 0.59 [95% CI, 0.30-1.13]; P=0.113) with device use. The trial sequential analysis determined an absence of evidence for all stroke (required information size of 71 650 [5.6%]) and disabling stroke (required information size of 337 256 [1.2%]). Conventional meta-analysis determined no significant difference in all-cause mortality (RR, 1.03 [95% CI, 0.49-2.17]; P=0.928) with device use. The trial sequential analysis determined that the futility boundary was reached (required information size of 5772 [69.3%]).Conclusions There are insufficient randomized controlled trial data on cerebral embolic protection device use to provide conclusive meta-analytic findings for stroke outcomes.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The rationale of using cerebral embolic protection devices during transcatheter aortic valve implantation
    C. Simsek
    B. E. Schölzel
    P. den Heijer
    J. Vos
    M. Meuwissen
    B. van den Branden
    A. J. J. IJsselmuiden
    Netherlands Heart Journal, 2020, 28 : 249 - 252
  • [22] The rationale of using cerebral embolic protection devices during transcatheter aortic valve implantation
    Simsek, C.
    Scholzel, B. E.
    den Heijer, P.
    Vos, J.
    Meuwissen, M.
    van den Branden, B.
    IJsselmuiden, A. J. J.
    NETHERLANDS HEART JOURNAL, 2020, 28 (05) : 249 - 252
  • [23] A Meta-Analysis of Embolic Protection Devices in the Prevention of Cerebrovascular Events after Transcatheter Aortic Valve Replacement
    Ansari, Mohammad M.
    Cardoso, Rhanderson N.
    Garcia, Daniel C.
    Spaziano, Marco
    de Marchena, Eduardo
    Brinster, Derek
    Scheinerman, S. Jacob
    Martucci, Giuseppe
    Piazza, Nicolo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B309 - B309
  • [24] Updated Meta-Analysis on Safety and Efficacy of Cerebral Embolic Protection Devices Among Patients Undergoing Transcatheter Aortic Valve Replacement
    Shrestha, Dhan B.
    Shtembari, Jurgen
    Lamichhane, Sandesh
    Baniya, Abinash
    Shahi, Manoj
    Sutton, Nadia R.
    Villablanca, Pedro A.
    CIRCULATION, 2022, 146
  • [25] Safety and efficacy of cerebral protection devices during transcatheter aortic valve implantation. A systematic review and meta-analysis
    Testa, Luca
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B268 - B269
  • [26] Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-Analysis
    Testa, Luca
    Latib, Azeem
    Casenghi, Matteo
    Gorla, Riccardo
    Colombo, Antonio
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (10):
  • [27] Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-analysis
    Testa, Luca
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) : S56 - S56
  • [28] Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-analysis
    Testa, Luca
    Latib, Azeem
    Colombo, Antonio
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S62 - S63
  • [29] Meta-analysis of the Safety and Efficacy of the Sentinel Cerebral Protection System in Transcatheter Aortic Valve Implantation
    Radwan, Yasser
    Al-abcha, Abdullah
    Salam, Mohammad Fahad
    Khor, Si Yuan
    Prasad, Rohan Madhu
    Elshafie, Ahmed
    Abela, George
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 152 : 169 - 170
  • [30] Cerebral embolic protection devices during transcatheter aortic valve implantation, the current state of the art
    Deveci, Onur Sinan
    Okutucu, Sercan
    Fatihoglu, Sefik Gorkem
    Oto, Ali
    ACTA CARDIOLOGICA, 2022, 77 (03) : 196 - 203