Cerebral Embolic Protection Devices in Transcatheter Aortic Valve Implantation: Meta-Analysis With Trial Sequential Analysis

被引:0
|
作者
Warraich, Nav [1 ,2 ]
Sa, Michel Pompeu [3 ]
Jacquemyn, Xander [4 ]
Kuno, Toshiki [5 ]
Serna-Gallegos, Derek [1 ,2 ]
Sultan, Ibrahim [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Cardiothorac Surg, Div Cardiac Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, UPMC Heart & Vasc Inst, Med Ctr, Pittsburgh, PA USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiac Surg, Boston, MA USA
[4] Katholieke Univ Leuven, Leuven, Belgium
[5] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiol, Boston, MA USA
来源
关键词
cerebral embolic protection devices; meta-analysis; TAVI; trial sequential analysis; RANDOMIZED EVALUATION; REPLACEMENT; LESIONS;
D O I
10.1161/JAHA.124.038869
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We aimed to reevaluate randomized controlled trial data on outcomes of cerebral embolic protection device use during transcatheter aortic valve implantation. A conventional meta-analysis followed by trial sequential analysis was conducted to evaluate the strength of the current evidence.Methods and Results Databases were searched for randomized controlled trials. Primary outcomes included all stroke, disabling stroke, and all-cause mortality. Conventional study-level meta-analysis was performed using random-effects modeling. Trial sequential analysis was conducted to generate adjusted significance boundaries, futility boundaries, and the required information size considering a type I error of 5% and a power of 90%. Seven trials were included with a total of 4031 patients, of whom 2171 were treated with a device and 1860 were not. Conventional meta-analysis showed no significant difference in all stroke (relative risk [RR], 0.85 [95% CI, 0.61-1.18]; P=0.339) and disabling stroke (RR, 0.59 [95% CI, 0.30-1.13]; P=0.113) with device use. The trial sequential analysis determined an absence of evidence for all stroke (required information size of 71 650 [5.6%]) and disabling stroke (required information size of 337 256 [1.2%]). Conventional meta-analysis determined no significant difference in all-cause mortality (RR, 1.03 [95% CI, 0.49-2.17]; P=0.928) with device use. The trial sequential analysis determined that the futility boundary was reached (required information size of 5772 [69.3%]).Conclusions There are insufficient randomized controlled trial data on cerebral embolic protection device use to provide conclusive meta-analytic findings for stroke outcomes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] META-ANALYSIS ON CEREBRAL EMBOLIC PROTECTION DEVICES DURING TRANSCATHETER AORTIC VALVE IMPLANTATION
    Bagur, Rodrigo
    Solo, Karla
    Nombela-Franco, Luis
    Kwok, Chun Shing
    Mamas, Mamas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1303 - 1303
  • [2] Safety and efficacy of cerebral embolic protection devices in transcatheter aortic valve implantation: a meta-analysis
    Tan, N.
    Gao, F.
    Mohammed, R. A.
    Lim, S. T.
    Aziz, Z. Abdul
    Govindasamy, S.
    Chao, V. T. T.
    Ewe, S. H.
    Ho, K. W.
    Yap, J.
    EUROPEAN HEART JOURNAL, 2023, 44 : 120 - 120
  • [3] Cerebral embolic protection devices for stroke prevention in transcatheter aortic valve implantation: a meta-analysis
    Camargo, D. Perez
    Travieso Gonzalez, A.
    Carnero Alcazar, M.
    Cobiella Carnicer, J.
    Maroto Castellanos, L. C.
    Taramasso, M.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2256 - 2256
  • [4] Neurological outcomes of transcatheter aortic valve implantation with or without cerebral embolic protection devices: A meta-analysis
    Perez-Camargo, Daniel
    Travieso, Alejandro
    Carnero-Alcazar, Manuel
    Taramasso, Maurizio
    Cobiella-Carnicer, Javier
    Maroto-Castellanos, Luis C.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (09):
  • [5] Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Implantation Systematic Review and Meta-Analysis
    Bagur, Rodrigo
    Solo, Karla
    Alghofaili, Saleh
    Nombela-Franco, Luis
    Kwok, Chun Shing
    Hayman, Samual
    Siemieniuk, Reed A.
    Foroutan, Farid
    Spencer, Frederick A.
    Vandvik, Per O.
    Schaeufele, Tim G.
    Mamas, Mamas A.
    STROKE, 2017, 48 (05) : 1306 - +
  • [6] Meta-Analysis of Usefulness of Cerebral Embolic Protection During Transcatheter Aortic Valve Implantation
    Ahmad, Yousif
    Howard, James P.
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 146 : 69 - 73
  • [7] Cerebral embolic protection devices during transcatheter aortic valve implantation: a meta-analysis of randomised controlled trials
    Reddy, R. K.
    Ahmad, Y.
    Arnold, A. D.
    Howard, J. P.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [8] Stroke reduction by cerebral embolic protection devices in transcatheter aortic valve implantation: a systematic review and Bayesian meta-analysis
    Heuts, Samuel
    Gabrio, Andrea
    Veenstra, Leo
    Maesen, Bart
    Kats, Suzanne
    Maessen, Jos G.
    Walton, Antony S.
    Nanayakkara, Shane
    Lansky, Alexandra J.
    van 't Hof, Arnoud W. J.
    Vriesendorp, Pieter A.
    HEART, 2024, 110 (11) : 757 - 765
  • [9] Cerebral Embolic Protection during Transcatheter Aortic Valve Implantation: Updated Systematic Review and Meta-Analysis
    Zahid, Salman
    Ullah, Waqas
    Khan, Muhammad Zia
    Uddin, Muhammad Faisal
    Rai, Devesh
    Abbas, Sakina
    Khan, Muhammad Usman
    Hussein, Ahmed
    Salama, Amr
    Bandyopadhyay, Dhrubajyoti
    Baibhav, Bipul
    Rao, Mohan
    Alam, Mahboob
    Alraies, M. Chadi
    Balla, Sudarshan
    Alkhouli, Mohamad
    Depta, Jeremiah P.
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (06)
  • [10] Cerebral Embolic Protection During Transcatheter Aortic Valve Implantation: Updated Systemic Review and Meta-Analysis
    Zahid, Salman
    Ubaid, Aamer
    Khan, Muhammad Atif
    Din, Mian Tanveer Ud
    Muhammadzai, Hamza Zahid Ullah
    Khan, Muhammmad
    Uddin, Muhammad Faisal
    Ullah, Waqas
    CIRCULATION, 2021, 144