Optimization of thermal resistance and thermal deformation in high heat-load zone of blast furnace cooling staves

被引:0
|
作者
Chen, Haifeng [1 ]
Zhai, Yuling [1 ]
Huang, Hao [1 ]
Li, Zhouhang [1 ]
Wang, Hua [1 ]
机构
[1] Kunming Univ Sci & Technol, Engn Res Ctr Met Energy Conservat & Emiss Reduct, Minist Educ, Kunming 650093, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
Cooling stave; High heat-load zone; Nanofluid; Internally-ribbed tube; Thermal resistance; Thermal deformation; COPPER STAVE; NANOFLUID; PERFORMANCE; SIMULATION; CONDUCTIVITY; TUBES; MODEL; FLOW;
D O I
10.1016/j.applthermaleng.2025.126292
中图分类号
O414.1 [热力学];
学科分类号
摘要
Blast furnace longevity is critically limited by the degradation of cooling staves in high heat-load zones, where excessive thermal deformation and inefficient heat dissipation accelerate structural failure. Proper temperature control of these staves is essential to mitigate such issues. The total thermal resistance from furnace gas to the environment consists of fixed and optimizable components. While the fixed thermal resistance is inherent to the furnace design, the optimizable convective resistance between working fluids and tube walls remains a key target for improvement, as conventional cooling methods (e.g., water in smooth tubes) struggle to balance heat extraction efficiency with mechanical durability under extreme thermal loads. Here, numerical simulations investigate the thermal performance of four configurations: water, CuO/water nanofluid, and Al2O3/water nanofluid in smooth or internally-ribbed tubes. Compared to the baseline (water in smooth tubes), the synergistic combination of 5 vol% Al2O3/water nanofluid and internally-ribbed tubes reduced optimizable thermal resistance by 72.03% and maximum thermal deformation by 17.58%, while increasing the heat transfer coefficient by 169.11%. These improvements stem from two mechanisms: (1) rib-induced asymmetrical vortices and swirling flows that disrupt thermal boundary layers and enhance fluid mixing, and (2) nanoparticle-driven conductive pathways that augment heat transfer via liquid-nanoparticle interactions. The results demonstrate a promising strategy to address the longstanding challenge of cooling stave degradation in blast furnaces, directly linking reduced thermal resistance to lower wall temperatures and suppressed deformation-critical factors for extending furnace lifespan.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Effect of cooling technique of blast furnace slag on the thermal behavior of solid cement bricks
    Sadek, Dina M.
    Journal of Cleaner Production, 2014, 79 : 134 - 141
  • [22] Thermal optimization of a high-heat-load double-muitilayer monochromator
    Brumund, Philipp
    Reyes-Herrera, Juan
    Morawe, Christian
    Dufrane, Thomas
    Isern, Helena
    Brochard, Thierry
    del Rio, Manuel Sanchez
    Detlefs, Carsten
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1423 - 1436
  • [23] INCREASING BLAST TEMPERATURE THROUGH OPTIMIZATION OF THERMAL PERFORMANCE OF BLAST-FURNACE STOVES IN ON-BLAST PERIOD
    SOVETKIN, VL
    SHVYDKII, VS
    SHKLYAR, FR
    YAROSHENKO, YG
    MOSUNOV, AA
    STEEL IN THE USSR, 1976, 6 (04): : 184 - 186
  • [24] Reaction Behaviors of Various Agglomerates in Reducing the Temperature of the Thermal Reserve Zone of the Blast Furnace
    Higuchi, Kenichi
    Kunitomo, Kazuya
    Nomura, Seiji
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2021, 107 (05): : 325 - 335
  • [25] Reaction Behaviors of Various Agglomerates in Reducing the Temperature of the Thermal Reserve Zone of the Blast Furnace
    Higuchi, Kenichi
    Kunitomo, Kazuya
    Nomura, Seiji
    ISIJ INTERNATIONAL, 2020, 60 (11) : 2366 - 2375
  • [26] THERMAL RESISTANCE OF ALKALI ACTIVATED BLAST FURNACE SLAG COMPOSITE WITH CHAMOTTE AGGREGATE
    Frybortova, Iva
    Rovnanik, Pavel
    Reznik, Bohuslav
    NON-TRADITIONAL CEMENT & CONCRETE IV, 2011, : 456 - 464
  • [27] Study of Ferrous Material Reduction based on Thermal Reserve Zone of Modern Blast Furnace
    Guo Liang
    Wu Sheng-li
    Zhang Li-hua
    Tuo Bi-yang
    CHEMICAL ENGINEERING AND MATERIAL PROPERTIES, PTS 1 AND 2, 2012, 391-392 : 65 - 70
  • [28] Thermal Optimization of a Solar Thermal Cooling Cogeneration Plant at Low Temperature Heat Recovery
    Srinivas, T.
    Reddy, B. V.
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2014, 136 (02):
  • [29] Influence of air cooled and granulated blast furnace slag on the thermal resistance of cyclic high-temperature concrete
    Feldrappe, Volkert
    Ehrenberg, Andreas
    Iravani, Ahmad
    Anders, Steffen
    ce/papers, 2023, 6 (06) : 262 - 268
  • [30] Influence of special pipe on temperature field and thermal stress field of cooling stave for blast furnace
    Lu, Zu'an
    Wu, Lijun
    Sun, Guoping
    Zhou, Weiguo
    Tongji Daxue Xuebao/Journal of Tongji University, 2012, 40 (09): : 1382 - 1386