Case Report: A novel method of needle-free transseptal puncture

被引:0
|
作者
Lee, Chia-Chen [1 ,2 ]
Chao, Chen-An [1 ,2 ]
Chang, Su-Huan [1 ,2 ]
Chen, Chun-Kai [1 ,2 ]
Chen, Yen-Siou [2 ,3 ]
Lin, Chang-En [1 ,2 ]
Jeng, Tsung-Ping [1 ,2 ]
Yu, Chih-Chieh [1 ,2 ]
机构
[1] Natl Taiwan Univ, Coll Med, Dept Internal Med, Taipei, Taiwan
[2] Natl Taiwan Univ, Coll Med & Hosp, Dept Internal Med, Div Cardiol, Taipei, Taiwan
[3] Fu Jen Catholic Univ Hosp, Dept Cardiol, Taipei, Taiwan
来源
关键词
electrophysiology; atrial fibrillation; transseptal puncture; intracardiac echocardiography; electrocautery; LEFT-HEART CATHETERIZATION; GUIDEWIRE; ABLATION;
D O I
10.3389/fcvm.2024.1493240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In the era of fluoroless catheter ablation (CA), achieving a successful transseptal puncture (TSP) presents a significant challenge. We introduce a novel technique for zero-fluoroscopy and cost-effective needle-free TSP.Case summary We describe two cases where a GMS-1 guidewire (0.025 inch, pigtail configuration; Toray Medical Co., Ltd., Japan) was utilized for TSP. This technique was performed using either fluoroscopy or intracardiac echocardiography (ICE). The procedure was completed successfully in both cases, with no complications reported.Conclusion The use of a 0.025 inch GMS-1 guidewire with an electrocautery technique enables effective transseptal puncture without the need for a needle or fluoroscopy. This novel approach offers a safe, efficient, and zero-fluoroscopic alternative for TSP.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Use of a novel needle wire in patients undergoing transseptal puncture associated with severe septal tenting
    Wieczorek, Marcus
    Hoeltgen, Reinhard
    Akin, Elvan
    Salili, Ali Reza
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 27 (01) : 9 - 13
  • [32] Use of a novel needle wire in patients undergoing transseptal puncture associated with severe septal tenting
    Marcus Wieczorek
    Reinhard Hoeltgen
    Elvan Akin
    Ali Reza Salili
    Journal of Interventional Cardiac Electrophysiology, 2010, 27 : 9 - 13
  • [33] Modified wire atrial septostomy with a reverse transseptal puncture in an infant: Case report
    Nagatomo, Yusaku
    Nagata, Hazumu
    Yamamura, Kenichiro
    Ohga, Shouichi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (05) : 865 - 868
  • [34] Towards the advance of a novel iontophoretic patch for needle-free buccal anesthesia
    do Couto, Renê Oliveira
    Cubayachi, Camila
    Duarte, Maíra Peres Ferreira
    Lopez, Renata Fonseca Vianna
    Pedrazzi, Vinícius
    De Gaitani, Cristiane Masetto
    de Freitas, Osvaldo
    do Couto, Renê Oliveira (rocouto@ufsj.edu.br), 1600, Elsevier Ltd (122):
  • [35] Towards the advance of a novel iontophoretic patch for needle-free buccal anesthesia
    do Couto, Rene Oliveira
    Cubayachi, Camila
    Duarte, Maira Peres Ferreira
    Lopez, Renata Fonseca Vianna
    Pedrazzi, Vinicius
    De Gaitani, Cristiane Masetto
    de Freitas, Osvaldo
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 122
  • [36] Algodystrophy Treated with Needle-Free Electroacupuncture and Raw Chinese Herbal Decoction: A Case Report and Review of Literature
    Miao, Edwin Yong
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2009, 15 (10) : 1131 - 1134
  • [37] Hope for needle-free glucose testing
    不详
    OPTOMETRY AND VISION SCIENCE, 2001, 78 (09) : 626 - 627
  • [38] A needle-free skin patch vaccination method for protection against anthrax
    Matyas, GR
    Yu, JM
    Glenn, GM
    Friedlander, AM
    Little, SF
    Alving, CR
    FASEB JOURNAL, 2004, 18 (05): : A820 - A821
  • [39] A New Concept of Needle-Free Jet Injector by the Impact Driven Method
    Mukda, Prachya
    Pianthong, Kulachate
    Seehanam, Wirapan
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2017, 11 (01):
  • [40] Formulating for Needle-Free Jet Injection
    Challener, Cynthia A.
    BIOPHARM INTERNATIONAL, 2015, 28 (04) : 38 - 41