Prediction of overall heat transfer coefficient in concentric tube heat exchangers using artificial neural networks: A comparative study with empirical correlations

被引:0
|
作者
Alsayah, Ahmed Mohsin [1 ]
Alshukri, Mohammed J. [1 ,2 ]
Ali, Samer [3 ]
Faraj, Jalal [4 ,5 ]
Khaled, Mahmoud [5 ,6 ]
机构
[1] Islamic Univ, Tech Engn Coll, Refrigerat & Air Conditioning Dept, Najaf, Iraq
[2] Kufa Univ, Fac Engn, Dept Mech Engn, Najaf 54002, Iraq
[3] Univ Artois, Univ Lille, Inst Mines Telecom, Lab Genie Civil & Geoenvironm,ULR 4515,LGCgE, F-59000 Lille, France
[4] Int Univ Beirut BIU, Energy & Thermofluid Grp, Beirut, Lebanon
[5] Lebanese Int Univ LIU, Energy & Thermo Fluid Grp, Bekaa, Lebanon
[6] Gulf Univ Sci & Technol, GUST Ctr Sustainable Dev, Mubarak Al Abdullah, Kuwait
关键词
Artificial neural network (ANN); U-value; Concentric tube heat exchanger; Laminar flow; Turbulent flow;
D O I
10.1016/j.icheatmasstransfer.2025.108723
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents the development and implementation of an Artificial Neural Network (ANN) model for predicting the U-value in a counter-flow concentric tube heat exchanger (CTHE). A dataset comprising 2,700 CFD simulations was generated by varying key parameters, including Reynolds numbers (1,000-20,000), fluid pairings (hot air-cold air, hot air-cold water,hot water-cold air, and hot water-cold water), inner diameters (0.01-0.05 m), diameter ratios (1.25, 1.5, and 3), and heat exchanger lengths (0.4-4 m). The simulations captured both laminar and turbulent flow regimes, providing a robust basis for training the ANN model. The neural network, comprising three hidden layers, L2 regularization and ReLU activation, demonstrated excellent accuracy, with a low mean absolute error (MAE) of 5.503 and mean absolute percentage error (MAPE) of 3.08%, as evaluated on the test dataset. The ANN model demonstrated superior performance compared to traditional empirical correlations from the literature, such as those by Baehr and Stephan, Dittus and Boelter, and Gnielinski, particularly in mixed flow regimes (laminar-turbulent and turbulent-laminar). While existing literature correlations in these regimes often exceeded 20% APE, our ANN model demonstrated a median APE of less than 1%. This illustrates the superiority of the artificial neural network (ANN) in capturing complex heat transport dynamics over empirical models. Furthermore, SHAP feature importance analysis revealed that the cold fluid thermal conductivity, hot fluid Reynolds number, hot fluid dynamic viscosity and inner diameter have the greatest impact on the overall heat transfer coefficient. The ANN model offers a flexible and accurate alternative to empirical correlations, with the potential to be extended to more complex heat exchanger configurations and additional performance metrics such as pressure drop and heat exchanger effectiveness.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Prediction of air leakage in heat exchangers for automotive applications using artificial neural networks
    Peta, Katarzyna
    Zurek, Jan
    2018 9TH IEEE ANNUAL UBIQUITOUS COMPUTING, ELECTRONICS & MOBILE COMMUNICATION CONFERENCE (UEMCON), 2018, : 721 - 725
  • [22] Predictions of heat transfer correlations for helically coiled tube-in-tube heat exchangers
    Sobota, Tomasz
    Archives of Thermodynamics, 2007, 28 (03) : 29 - 40
  • [23] Prediction of heat transfer coefficient on the fin inside one-tube plate finned-tube heat exchangers
    Chen, HT
    Song, JP
    Wang, YT
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (13) : 2697 - 2707
  • [24] Empirical correlations for heat transfer and flow friction characteristics of herringbone wavy fin-and-tube heat exchangers
    Wang, CC
    Hwang, YM
    Lin, YT
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (05): : 673 - 680
  • [25] CONSTANT OR LINEAR OVERALL HEAT TRANSFER COEFFICIENT IN TUBULAR EXCHANGERS
    DODD, R
    CHEMICAL ENGINEER-LONDON, 1970, (239): : C190 - &
  • [26] Assessment of boiling heat transfer correlations in the modelling of fin and tube heat exchangers
    Garcia-Cascales, J. R.
    Vera-Garcia, F.
    Corberan-Salvador, J. M.
    Gonzalvez-Macia, J.
    Fuentes-Diaz, David
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (06): : 1004 - 1017
  • [27] Assessment of condensation heat transfer correlations in the modelling of fin and tube heat exchangers
    Vera-Garcia, F.
    Garcia-Cascales, J. R.
    Corberan-Salvador, J. M.
    Gonzalvez-Macia, J.
    Fuentes-Diaz, David
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (06): : 1018 - 1028
  • [28] Determination of heat transfer correlations for plate-fin-and-tube heat exchangers
    Taler, D
    HEAT AND MASS TRANSFER, 2004, 40 (10) : 809 - 822
  • [29] Air side heat transfer coefficient in plate finned tube heat exchangers
    Mihailovic, Milos
    Milovancevic, Uros
    Genic, Srbislav
    Jacimovic, Branislav
    Otovic, Milena
    Kolendic, Petar
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 388 - 399
  • [30] Determination of heat transfer correlations for plate-fin-and-tube heat exchangers
    Dawid Taler