Nuclear fuel imaging using position-sensitive detectors

被引:0
|
作者
Saariokari, S. [1 ]
Dendooven, P. [1 ]
Laassiri, M. [1 ]
Brucken, J. E. [1 ]
机构
[1] Univ Helsinki, Helsinki Inst Phys, Helsinki, Finland
来源
JOURNAL OF INSTRUMENTATION | 2025年 / 20卷 / 03期
关键词
Compton imaging; Gamma detectors (scintillators; CZT; HPGe; HgI etc);
D O I
10.1088/1748-0221/20/03/C03012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We are evaluating the performance of a Passive Gamma Emission Tomography (PGET) device [1] equipped with 3D position-sensitive cadmium zinc telluride (CZT) gamma-ray detectors when used for inspecting spent nuclear fuel assemblies (SFAs). Before their disposal in a geological repository, SFAs undergo verification using the PGET device, which was developed under the guidance of the IAEA and approved by the IAEA for safeguards inspections. Recent advancements in imaging detector technology may offer a method to extend the capabilities of such devices beyond standard safeguards applications, allowing an efficient non-invasive way to accurately characterise the properties of nuclear fuel assemblies. The efficiency of the currently used small CZT detectors is restricted by the limited likelihood of full gamma-ray absorption, which is needed for optimal imaging information. Employing larger CZT detectors would increase the probability of capturing the full energy of gamma rays, thereby enhancing the sensitivity of the PGET device and the quality of the reconstructed images. Large CZT detectors need to be position-sensitive to determine through which collimator slit a gamma ray travelled. Position sensitivity results from the pixelated readout of the CZT crystals. Pixelation potentially increases the spatial resolution of the system, which is currently determined root by the collimator used. Pixelation allows resolving the position of arrival up to (readout pitch)/ 12. We are additionally exploring the potential of utilising Compton imaging to provide information on the origin of gamma rays along the SFA. Monte Carlo simulations are used to estimate the increase in full photon absorption efficiency when comparing large and current, small, crystals. A dedicated simulation is created using Geant4, where gamma rays of energy 661.7 keV and 1274 keV are targeted to the model describing the approved apparatus now equipped with 22 mm x 22 mm x 10 mm crystals of CZT. It is observed that the efficiency for photon absorption in this case is greatly increased when compared to the existing detectors.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Position-sensitive detectors of nuclear radiation and a study of their current−voltage characteristic
    Yo. K. Toshmurodov
    Instruments and Experimental Techniques, 2017, 60 : 605 - 607
  • [22] FAST TIMING POSITION-SENSITIVE DETECTORS
    KLEIN, C
    TROTSCHER, J
    WOLLNIK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2): : 146 - 147
  • [23] Noise analysis for position-sensitive detectors
    Narayanan, C
    Buckman, AB
    Busch-Vishniac, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (05) : 1137 - 1144
  • [24] PERFORMANCE OF POSITION-SENSITIVE GERMANIUM DETECTORS IN NUCLEAR-REACTION EXPERIMENTS
    HAMACHER, A
    MACHNER, H
    NOLTE, M
    PALARCZYK, M
    PROTIC, D
    RIEPE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2): : 128 - 132
  • [25] POSITION-SENSITIVE DETECTORS AND WEISSENBERG DIFFRACTOMETERS
    PRINCE, E
    SANTORO, A
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S234 - S234
  • [26] EPITAXIAL SILICON POSITION-SENSITIVE DETECTORS
    SHIRAISHI, F
    KIM, C
    KIM, H
    KIKUCHI, K
    HUSIMI, K
    OHKAWA, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 554 - 557
  • [27] DEVELOPMENT OF POSITION-SENSITIVE SCINTILLATION DETECTORS
    ROGERS, EH
    WHITESID.H
    ARENS, JF
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 455 - 455
  • [28] DIGITAL PROCESSOR FOR POSITION-SENSITIVE DETECTORS
    FISCHER, BE
    NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (01): : 173 - 181
  • [29] Position-sensitive vacuum photon detectors
    Gys, Thierry
    Joram, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 970
  • [30] SUPERCONDUCTING STRIP DETECTORS AS POSITION-SENSITIVE PARTICLE DETECTORS
    SCHERSCHEL, M
    FINKBEINER, F
    ZHAO, SP
    MAIER, T
    LERCH, P
    ZEHNDER, A
    OTT, HR
    PHYSICA B, 1994, 194 : 2351 - 2352