Assessing Accuracy of a Wrist-Worn Wearable Device Over Changing Levels of Activity

被引:0
|
作者
Flett, Isaac L. [1 ]
Su, Yunpeng [1 ]
Cameron, Chris [1 ]
Zhou, Cong [1 ]
Pearson, Lui Holder [1 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2024年 / 58卷 / 24期
关键词
Devices and sensors; Identification and validation; Biosignal analysis and interpretation; QUANTIFYING AGITATION; HEART-RATE;
D O I
10.1016/j.ifacol.2024.11.072
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The widespread popularity of wearable devices has offered new avenues for continuous heart rate (HR) monitoring. A variety of other health related metrics including stress, sleep, and daily energy are being derived by heart rate and other sensors on the device. These or similar metrics could prove useful in critical care and other inpatient settings. This study evaluates the accuracy of a commercial smartwatch's photoplethysmography (PPG) sensor in tracking HR changes across various physical activities, comparing its performance to an electrocardiography (ECG)-based chest strap. Eighteen participants, aged 20 to 50, engaged in a series of tasks including rest, walking, and stair climbing, while HR data were collected via both devices. During rest, the smartwatch provided HR measurements within 5% of the chest strap values for a significant majority of readings (73.0% for the right wrist and 78.8% for the left). However, accuracy declined during physical activities, with the disparity becoming more pronounced during stair climbing (62.0% for the right wrist and 69.6% for the left). Excluding the initial 60 seconds of each activity from the analysis improved smartwatch accuracy, particularly during walking and the second rest period, as the smartwatches often failed to detect sharp changes in heart rate when the activity effort suddenly changed. This study highlights smartwatch reliability in static conditions and its limitations in accurately capturing rapid HR fluctuations during dynamic activities. These outcomes will impact their potential clinical utility in some cases. Copyright (C) 2024 The Authors. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:409 / 414
页数:6
相关论文
共 50 条
  • [11] Accuracy of Wrist-Worn Heart Rate Monitors
    Wang, Robert
    Blackburn, Gordon
    Desai, Milind
    Phelan, Dermot
    Gillinov, Lauren
    Houghtaling, Penny
    Gillinov, Marc
    JAMA CARDIOLOGY, 2017, 2 (01) : 104 - 106
  • [12] Accuracy of Wrist-Worn Activity Monitors during Treadmill and Elliptical Ergometry
    Smith, John D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 365 - 365
  • [13] A Wrist-Worn Thermohaptic Device for Graceful Interruption
    Bolton, Frank
    Jalaliniya, Shahram
    Pederson, Thomas
    INTERACTION DESIGN AND ARCHITECTURES, 2015, (26) : 39 - 54
  • [14] A Review of Wrist-Worn Wearable: Sensors, Models, and Challenges
    Al-Eidan, Rasha M.
    Al-Khalifa, Hend
    Al-Salman, Abdul Malik
    JOURNAL OF SENSORS, 2018, 2018
  • [15] The Accuracy of Heart Rate Monitoring by Some Wrist-Worn Activity Trackers
    Cadmus-Bertram, Lisa
    Gangnon, Ronald
    Wirkus, Emily J.
    Thraen-Borowski, Keith M.
    Gorzelitz-Liebhauser, Jessica
    ANNALS OF INTERNAL MEDICINE, 2017, 166 (08) : 610 - +
  • [16] Detecting Distracted Driving Using a Wrist-Worn Wearable
    Goel, Bharti
    Dey, Arup Kanti
    Bharti, Pratool
    Ben Ahmed, Kaoutar
    Chellappan, Sriram
    2018 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS (PERCOM WORKSHOPS), 2018,
  • [17] Effect Of Hand Dominance On Accuracy Of Wrist-worn Physical Activity Trackers
    Kelley, Elizabeth P.
    Nelson, M. Benjamin
    Bock, Josh M.
    Tuttle, Mary
    Steeves, Jeremy A.
    Kaminsky, Leonard A.
    Montoye, Alexander H. K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 780 - 780
  • [18] Development of digital biomarkers for resting tremor and bradykinesia using a wrist-worn wearable device
    Nikhil Mahadevan
    Charmaine Demanuele
    Hao Zhang
    Dmitri Volfson
    Bryan Ho
    Michael Kelley Erb
    Shyamal Patel
    npj Digital Medicine, 3
  • [19] Accuracy Of Wrist-worn Activity Monitors At Three Walking Speeds On The Treadmill
    Smith, John D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 783 - 783
  • [20] Optical wrist-worn device for sleep monitoring
    Renevey, Ph.
    Delgado-Gonzalo, R.
    Lemkaddem, A.
    Proenca, M.
    Lemay, M.
    Sola, J.
    Tarniceriu, A.
    Bertschi, M.
    EMBEC & NBC 2017, 2018, 65 : 615 - 618