Textile Organic Electrochemical Transistor for Non-Invasive Glucose Sensing

被引:0
|
作者
Brendgen, Rike [1 ]
Grethe, Thomas [2 ]
Schwarz-Pfeiffer, Anne [2 ]
机构
[1] Niederrhein Univ Appl Sci, Res Inst Text & Clothing FTB, Webschulstr 31, D-41065 Monchengladbach, Germany
[2] Niederrhein Univ Appl Sci, Fac Text & Clothing Technol, Webschulstr 31, D-41065 Monchengladbach, Germany
来源
MICRO-SWITZERLAND | 2024年 / 4卷 / 04期
关键词
organic electrochemical transistor; smart textiles; E-textiles; glucose sensing; non-invasive; biosensing; BLOOD-GLUCOSE; BIOSENSORS; OXIDASE; SENSORS;
D O I
10.3390/micro4040033
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The global rise in diabetes has highlighted the urgent need for continuous, non-invasive health monitoring solutions. Traditional glucose monitoring methods, which are invasive and often inconvenient, have created a demand for alternative technologies that can offer comfort, accuracy, and real-time data. In this study, the development of a textile-based organic electrochemical transistor (OECT) is presented, designed for non-invasive glucose sensing, aiming to integrate this technology seamlessly into everyday clothing. The document details the design, optimization, and testing of a one-component textile-based OECT, featuring a porous PEDOT:PSS structure and a glucose oxidase-modified electrolyte for effective glucose detection in sweat. The research demonstrates the feasibility of using this textile-based OECT for non-invasive glucose monitoring, with enhanced sensitivity and specificity achieved through the integration of glucose oxidase within the electrolyte and the innovative porous PEDOT:PSS design. These findings suggest a significant advancement in wearable health monitoring technologies, providing a promising pathway for the development of smart textiles capable of non-invasively tracking glucose levels. Future work should focus on refining this technology for clinical use, including individual calibration for accurate blood glucose correlation and its integration into commercially available smart textiles.
引用
收藏
页码:530 / 551
页数:22
相关论文
共 50 条
  • [21] Simulation on how to customize glucose adjustment method for non-invasive blood glucose sensing by NIRS
    Min, Xiaolin
    Jiang, Jingying
    Zou, Da
    Liu, Rong
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2013, 8580
  • [22] Non-Invasive Glucose Sensing Technologies and Products: A Comprehensive Review for Researchers and Clinicians
    Di Filippo, Daria
    Sunstrum, Frederique N.
    Khan, Jawairia U.
    Welsh, Alec W.
    SENSORS, 2023, 23 (22)
  • [23] Cylindrical Dielectric Resonator Antenna Sensor for Non-invasive Glucose Sensing Application
    Hasan, Md Nazmul
    Tamanna, Saheda
    Singh, Padam
    Nadeem, Md Danish
    Rudramuni, Mahabaleshwar
    2019 6TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2019, : 961 - 964
  • [24] Hydrogel-based electrochemical sensor for non-invasive and continuous glucose monitoring
    Park, Habeen
    Lee, Ji-Young
    Kim, Dong-Chul
    Koh, Younggook
    Cha, Junhoe
    INTERNATIONAL CONFERENCE ON NANO-BIO SENSING, IMAGING, AND SPECTROSCOPY 2017, 2017, 10324
  • [25] Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy
    Jiang, Jingying
    Zhang, Lingling
    Gong, Qiliang
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [26] Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing
    Zhang, Wanjie
    Liu, Rong
    Zhang, Wen
    Jia, Hao
    Xu, Kexin
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (06): : 789 - 802
  • [27] Non-invasive glucose measurements via amperometric sensing with iontophoretic sampling.
    Tierney, MJ
    Burns, MD
    Kim, HL
    Tamada, JA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 182 - ANYL
  • [28] In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring
    Pickup, J
    McCartney, L
    Rolinski, O
    Birch, D
    BRITISH MEDICAL JOURNAL, 1999, 319 (7220): : 1289 - U31
  • [29] Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
    Shokrekhodaei, Maryamsadat
    Quinones, Stella
    SENSORS, 2020, 20 (05)
  • [30] BLOOD GLUCOSE SENSING THROUGH SKIN BY NON-INVASIVE FINGER TOUCH METER
    Kakkar, T.
    Richards, B.
    Ajjan, R.
    Saha, S.
    Grant, P.
    Jose, G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A40 - A40