Sensitive Voltammetric Detection of Acetaminophen on CuONPs-MWCNTs Modified Glassy Carbon Electrode with Enhancement Effect of Anionic Surfactant

被引:0
|
作者
Hegde, Rajesh N. [1 ]
Vishwanatha, P. [1 ]
Nandibewoor, Sharanappa T. [2 ]
机构
[1] Sri Dharmasthala Manjunatheshwara Coll, Dept PG Studies & Res Chem, Ujire 574240, Karnataka, India
[2] KLE Technol Univ, Hubballi 580031, Karnataka, India
来源
关键词
voltammetry; acetaminophen; surfactant; nanoparticles; sensor;
D O I
10.30744/brjac.2179-3425.AR-17-2024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, a voltammetric method using differential pulse voltammetric technique was developed for the assessment of antipyretic and analgesic drug, acetaminophen. The CuO nanoparticles were prepared and characterized. A glassy carbon electrode (GCE) fabricated with the suspension of CuO nanoparticles (CuONPs) and multi-walled carbon nanotubes (MWCNTs) were used. The modified electrode showed improved anodic peak current by introducing an anionic surfactant sodium dodecyl sulphate in phosphate buffer solution. The effect of the pH of the supporting electrolyte, the amount of nanoparticle suspension and the surfactant concentration was studied at a physiological pH of 7.4. Using differential pulse voltammetry, the fabricated electrode showed linear dynamic range from 9 to 160 nM of acetaminophen concentration. From the calibration plot, the computed detection limit was 5.06 nM and quantification limit was 16.88 nM. The developed method was tested for its reproducibility and assay during a day and intraday as well. The developed process was fruitfully applied to detect acetaminophen in pediatric oral suspensions administered to infants.
引用
收藏
页码:34 / 45
页数:12
相关论文
共 50 条
  • [41] Sensitive voltammetric determination of testosterone in pharmaceuticals and human urine using a glassy carbon electrode in the presence of cationic surfactant
    Levent, Abdulkadir
    Altun, Ahmet
    Yardim, Yavuz
    Senturk, Zuhre
    ELECTROCHIMICA ACTA, 2014, 128 : 54 - 60
  • [42] Bismuth vanadate modified glassy carbon electrode for sensitive electrochemical antibiotic detection
    Timmy Unya Anak Nedy
    Mohammad Aliff bin Ali Rahman
    Ellie Yi Lih Teo
    Pang Hung Yiu
    Elisha Yiu
    Alvin Lim Teik Zheng
    Yoshito Andou
    Journal of Nanoparticle Research, 2025, 27 (4)
  • [43] Signal enhancement for electrochemical detection at glassy carbon electrode modified with phenyl layer
    Hong, HG
    Porter, MD
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 578 (01): : 113 - 119
  • [44] Simultaneous Voltammetric Detection of Acetaminophen and Caffeine Base on Cassava Starch-Fe3O4 Nanoparticles Modified Glassy Carbon Electrode
    Mulyasuryani, Ani
    Tjahjanto, Rachmat Triandi
    Andawiyah, Robi'atul
    CHEMOSENSORS, 2019, 7 (04)
  • [45] Sensitive Voltammetric Detection of Metronidazole Based on Three-Dimensional Graphene-Like Carbon Architecture/Polythionine Modified Glassy Carbon Electrode
    Yang, Mei
    Guo, Manli
    Feng, Yanlong
    Lei, Yanming
    Cao, Yujuan
    Zhu, Debin
    Yu, Ying
    Ding, Li
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (11) : B530 - B535
  • [46] Electrocatalytical oxidation and sensitive determination of acetaminophen on glassy carbon electrode modified with graphene-chitosan composite
    Zheng, Meixia
    Gao, Feng
    Wang, Qingxiang
    Cai, Xili
    Jiang, Shulian
    Huang, Lizhang
    Gao, Fei
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (03): : 1514 - 1520
  • [47] A sensitive voltammetric sensor for taxifolin based on graphene nanosheets with certain orientation modified glassy carbon electrode
    Wang, Fei
    Wu, Yanju
    Lu, Kui
    Ye, Baoxian
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 188 - 194
  • [48] A sensitive bisphenol A voltammetric sensor relying on AuPd nanoparticles/graphene composites modified glassy carbon electrode
    Su, Bingyuan
    Shao, Huilin
    Li, Na
    Chen, Xiaomei
    Cai, Zhixiong
    Chen, Xi
    TALANTA, 2017, 166 : 126 - 132
  • [49] Sensitive voltammetric determination of baicalein at DNA Langmuir-Blodgett film modified glassy carbon electrode
    Wang, Fei
    Zhao, Fangyuan
    Zhang, Yanzheng
    Yang, Huige
    Ye, Baoxian
    TALANTA, 2011, 84 (01) : 160 - 168
  • [50] Glassy carbon electrode modified with organic-inorganic pillared montmorillonites for voltammetric detection of mercury
    Chen, Baohong
    Wang, Lishi
    Huang, Xinjian
    Wu, Pingxiao
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 335 - 341