Monte Carlo calculated beam quality correction factors for high energy photon and electron fields

被引:0
|
作者
Czarnecki, Damian [1 ]
Zink, Klemens [1 ,2 ]
机构
[1] Univ Appl Sci THM, Inst Med Phys & Radiat Protect, Wiesenstr 14, D-35390 Giessen, Germany
[2] Marburg Univ Hosp, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
关键词
Dosimetry; Beam quality correction factor; Ionization chamber; Monte carlo simulation; REFERENCE DOSIMETRY;
D O I
10.1016/j.ejmp.2025.104939
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although several studies provide data on reference dosimetry, ionization chambers are in clinical use worldwide, for which no or only a few correction factors for beam quality are available. The aim of this study was to calculate beam quality correction factors in electron and photon fields for four cylindrical ionization chamber, i.e. CC08, CC04, Razor T Chamber and Razor T Nano Chamber (all IBA, Dosimetry, Schwarzenbruck, Germany). Method: Monte Carlo simulations were performed with the EGSnrc code system to calculate the beam quality correction factor k(Q). Therefore, a detailed Monte Carlo based model of the four ionization chambers were created to calculate the dose in the sensitive volume. Electron and photon spectra of clinical linear accelerators within the entire energy range of therapeutic linear accelerators were used as radiation source. Results: k(Q) values as a function of the beam quality specifiers TPR20,10 and R-50 were calculated for high energy photon and electron fields, respectively. The data was fitted against recommended equations for photon and electron dosimetry with a chi(2) between 6.4e-7 and 4.2e-6. Conclusion: Electron and photon beam quality correction factors k(Q) were calculated by Monte Carlo simulations for the cylindrical ionization chambers CC08, CC04, Razor (TM) Chamber and Razor (TM) Nano Chamber to provide k(Q) values for absolute dosimetry according to the TRS 398 dosimetry protocol.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Monte Carlo simulation of small electron fields collimated by the integrated photon MLC
    Mihaljevic, Josip
    Soukup, Martin
    Dohm, Oliver
    Alber, Markus
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (03): : 829 - 843
  • [42] The Effect of Lead Heterogeneity on the Commercial Electron Monte Carlo Dose Calculation for High Energy Electron Beam
    Kong, C. W., IV
    Geng, H.
    Ho, Y. W.
    Lam, W. W.
    Wong, W. K. R.
    Lee, T. Y.
    Lee, M. H. C.
    Cheung, K. Y.
    Yu, S. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E679 - E680
  • [43] Electron Monte Carlo: An Analysis of Cutout Factors for Irregularly Shaped Electron Fields
    Mensah-Brown, N.
    Neba, N.
    Altundal, Y.
    Kile, L.
    Saleh, H.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [44] Correction factors for commissioning and patient specific quality assurance of stereotactic fields in a Monte Carlo based treatment planning systemTPS correction factors
    Simon K. Goodall
    Pejman Rowshanfarzad
    Martin A. Ebert
    Physical and Engineering Sciences in Medicine, 2023, 46 : 735 - 745
  • [45] Monte Carlo calculated detector-specific correction factors for Elekta radiosurgery cones
    Mon, P. S. Renil
    Devi, V. N. Meena
    Bhasi, Saju
    Nair, Sneha S.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (02):
  • [46] Validation of Monte Carlo calculated correction factors for MRI-linac reference dosimetry
    O'Brien, D. J.
    Roberts, D. A.
    Towe, S.
    Ibbott, G.
    Sawakuchi, G. O.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S376 - S376
  • [47] MONTE CARLO CALCULATED ELECTRON MLC (EMLC) FIELDS COMBINED WITH PHOTON IMRT IMPROVES DOSE DISTRIBUTIONS IN POST-MASTECTOMY RADIOTHERAPY
    Vatanen, T.
    Traneus, E.
    Lahtinen, T.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S419 - S419
  • [48] Monte Carlo estimation of electron contamination in a 18 MV clinical photon beam
    Allahverdi, M.
    Zabihzadeh, M.
    Ay, M. R.
    Mahdavi, S. R.
    Shahriari, M.
    Mesbahi, A.
    Alijanzadeh, H.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2011, 9 (01): : 15 - 28
  • [49] Monte Carlo study on electron contamination and output factors of small field dosimetry in 6 MV photon beam
    Yani, Sitti
    Dirgayussa, I. Gde Eka
    Rhani, Mohamad Fahdillah
    Soh, Roger C. X.
    Haryanto, Freddy
    Arif, Idam
    SMART SCIENCE, 2016, 4 (02): : 87 - 94
  • [50] Monte Carlo simulated beam quality and perturbation correction factors for ionization chambers in monoenergetic proton beams
    Kretschmer, Jana
    Dulkys, Anna
    Brodbek, Leonie
    Stelljes, Tenzin Sonam
    Looe, Hui Khee
    Poppe, Bjoern
    MEDICAL PHYSICS, 2020, 47 (11) : 5890 - 5905