Monte Carlo calculated beam quality correction factors for high energy photon and electron fields

被引:0
|
作者
Czarnecki, Damian [1 ]
Zink, Klemens [1 ,2 ]
机构
[1] Univ Appl Sci THM, Inst Med Phys & Radiat Protect, Wiesenstr 14, D-35390 Giessen, Germany
[2] Marburg Univ Hosp, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
关键词
Dosimetry; Beam quality correction factor; Ionization chamber; Monte carlo simulation; REFERENCE DOSIMETRY;
D O I
10.1016/j.ejmp.2025.104939
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although several studies provide data on reference dosimetry, ionization chambers are in clinical use worldwide, for which no or only a few correction factors for beam quality are available. The aim of this study was to calculate beam quality correction factors in electron and photon fields for four cylindrical ionization chamber, i.e. CC08, CC04, Razor T Chamber and Razor T Nano Chamber (all IBA, Dosimetry, Schwarzenbruck, Germany). Method: Monte Carlo simulations were performed with the EGSnrc code system to calculate the beam quality correction factor k(Q). Therefore, a detailed Monte Carlo based model of the four ionization chambers were created to calculate the dose in the sensitive volume. Electron and photon spectra of clinical linear accelerators within the entire energy range of therapeutic linear accelerators were used as radiation source. Results: k(Q) values as a function of the beam quality specifiers TPR20,10 and R-50 were calculated for high energy photon and electron fields, respectively. The data was fitted against recommended equations for photon and electron dosimetry with a chi(2) between 6.4e-7 and 4.2e-6. Conclusion: Electron and photon beam quality correction factors k(Q) were calculated by Monte Carlo simulations for the cylindrical ionization chambers CC08, CC04, Razor (TM) Chamber and Razor (TM) Nano Chamber to provide k(Q) values for absolute dosimetry according to the TRS 398 dosimetry protocol.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Monte Carlo calculated beam quality correction factors for high energy electron beams
    Alissa, Mohamad
    Zink, Klemens
    Roeser, Arnd
    Flatten, Veronika
    Schoenfeld, Andreas A.
    Czarnecki, Damian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 117
  • [2] Monte Carlo calculated beam quality correction factors for photon reference dosimetry
    Czarnecki, D.
    Alissa, M.
    Schoenfeld, A. A.
    Zink, K.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S729 - S730
  • [3] Monte Carlo calculated beam quality correction factors for proton beams
    Goma, C.
    Andreo, P.
    Sempau, J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S36 - S37
  • [4] Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams
    Alissa, Mohamad
    Zink, Klemens
    Tessier, Frederic
    Schoenfeld, Andreas A.
    Czarnecki, Damian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 94 : 17 - 23
  • [5] Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields
    Czarnecki, D.
    Zink, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (08): : 2431 - 2444
  • [6] Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors
    Wulff, J.
    Heverhagen, J. T.
    Zink, K.
    Kawrakow, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4481 - 4493
  • [7] Monte Carlo calculated beam quality correction factors for ionization chambers in carbon ion beams
    Baumann, Kilian
    Derksen, Larissa
    Stolzenberg, Jessica
    Sasse, Pascal
    Zink, Klemens
    Adeberg, Sebastian
    Looe, Hui Khee
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3377 - S3380
  • [8] Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams
    Wulff, J.
    Heverhagen, J. T.
    Zink, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11): : 2823 - 2836
  • [9] Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
    Araki, Fujio
    Hanyu, Yuji
    Fukuoka, Miyoko
    Matsumoto, Kenji
    Okumura, Masahiko
    Oguchi, Hiroshi
    MEDICAL PHYSICS, 2009, 36 (07) : 2992 - 3001
  • [10] Spectral analysis of Monte Carlo calculated fluence correction and cema conversion factors for high- energy photon beams at different depths
    Roers, Julian
    Czarnecki, Damian
    Alissa, Mohamad
    Zink, Klemens
    FRONTIERS IN PHYSICS, 2023, 10