Influence of fabrication method on the manufacturing accuracy and internal discrepancy of removable partial dentures: A systematic review and meta-analysis

被引:0
|
作者
Rokhshad, Rata [1 ,2 ]
Tehrani, Azita Mazaheri [3 ]
Zarbakhsh, Arash [3 ]
Revilla-Leon, Marta [4 ,5 ,6 ]
机构
[1] WHO Focus Grp Hlth, Top Grp Dent Diagnost & Digital Dent, ITU, Berlin, Germany
[2] Boston Univ, Med Ctr, Dept Med, Sect Endocrinol, Boston, MA USA
[3] Islamic Azad Univ, Fac Dent, Prosthodont Dept, Tehran Med Sci, Tehran, Iran
[4] Univ Washington, Sch Dent, Dept Restorat Dent, Grad Prosthodont, Seattle, WA USA
[5] Kois Ctr, Res & Digital Dent, Seattle, WA USA
[6] Tufts Univ, Dept Prosthodont, Boston, MA USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2025年 / 133卷 / 03期
关键词
COMPUTER-AIDED-DESIGN;
D O I
10.1016/j.prosdent.2023.04.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem: Removable partial dentures (RPDs) can be fabricated with conventional casting procedures or computer-aided design and computer-aided manufacturing (CAD-CAM) technologies; however, the manufacturing accuracy and internal discrepancy differences among these manufacturing methods remain uncertain. Purpose: The purpose of this systematic review and meta-analysis was to assess the influence of the fabricating method (casting, milling, or additive manufacturing) on the accuracy and internal discrepancy of RPDs. Material and methods: An electronic search of the literature was performed in 6 databases: PubMed/Medline, Embase, Web of Science, Scopus, Cochrane, and Google Scholar. The studies that assessed the accuracy and internal discrepancy of RPDs fabricated from casting, milling, and additive manufacturing were included. Studies reporting gaps (mean) and standard deviations were included in the meta-analysis. Publication bias was identified using funnel plot asymmetry and the Egger test. Results: A total of 25 articles were included. The internal discrepancy of the additively manufactured RPDs ranged from 14.4 to 511 mu m and from 7 to 419 mu m in conventionally fabricated RPDs. For the milling method, 20 to 66 mu m horizontal and 17 to 59 mu m vertical discrepancies were reported. The Egger tests indicated no publication bias among the studies that were included in the meta-analysis. Four included studies resulted in more than the acceptable clinical gap (311 mu m) for the CAD-CAM method. Independently of the manufacturing method, the greatest internal discrepancies reported were observed under the major connectors. RPDs fabricated by using CAD-CAM techniques required fewer clinical appointments, the RPD design was easier to reproduce, and laboratory time was less than with conventional procedures. However, the reviewed studies described several disadvantages, including limited RPD design programs, difficulties in defining the occlusal plane, expensive materials, and increased laboratory cost. Conclusions: Additive and subtractive technologies provide accurate methods for RPD fabrication; however, all challenges, including limited design software programs have not yet been overcome, and casting is still needed when the framework pattern is milled or printed.
引用
收藏
页码:724 / 735
页数:12
相关论文
共 50 条
  • [31] Additive Manufacturing of Dental Ceramics: A Systematic Review and Meta-Analysis
    Al Hamad, Khaled Q.
    Al-Rashdan, Bashar A.
    Ayyad, Jad Q.
    Al Omrani, Leen M.
    Sharoh, Ayat M.
    Al Nimri, Adnan M.
    Al-Kaff, Fatma T.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (08): : E67 - E86
  • [32] Accuracy of endometrial biopsy by Pipelle: A systematic review and meta-analysis
    Gou, J.
    Li, Z. Y.
    ANNALS OF ONCOLOGY, 2019, 30
  • [33] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [34] Prognostic accuracy of the SCORTEN tool: A systematic review and meta-analysis
    Liu, Zhao Feng
    Chew, Christopher
    Kuruvilla, Nidhin
    Kern, Johannes S.
    Gin, Douglas
    AUSTRALASIAN JOURNAL OF DERMATOLOGY, 2023, 64 : 33 - 33
  • [35] Accuracy of intracranial pressure monitoring: systematic review and meta-analysis
    Lucia Zacchetti
    Sandra Magnoni
    Federica Di Corte
    Elisa R. Zanier
    Nino Stocchetti
    Critical Care, 19
  • [36] Accuracy of Presepsin in Sepsis Diagnosis: A Systematic Review and Meta-Analysis
    Wu, Jiayuan
    Hu, Liren
    Zhang, Gaohua
    Wu, Fenping
    He, Taiping
    PLOS ONE, 2015, 10 (07):
  • [37] The diagnostic accuracy of procalcitonin for bacteraemia: a systematic review and meta-analysis
    Hoeboer, S. H.
    van der Geest, P. J.
    Nieboer, D.
    Groeneveld, A. B. J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2015, 21 (05) : 474 - 481
  • [38] Diagnostic Accuracy of the ID Migraine: A Systematic Review and Meta-Analysis
    Cousins, Grainne
    Hijazze, Samira
    Van de Laar, Floris A.
    Fahey, Tom
    HEADACHE, 2011, 51 (07): : 1140 - 1148
  • [39] Ultrasound accuracy in acute diverticulitis: A systematic review and Meta-analysis
    Shokoohi, Hamid
    Peksa, Gary D.
    Hutchison, Ainsley
    Al Jalbout, Nour
    Montoya, Kristofer
    Westrick, Jennifer C.
    Goldsmith, Andrew
    Nazerian, Peiman
    Gottlieb, Michael
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2025, 92 : 96 - 103
  • [40] Quotation Accuracy of Systematic Review and Meta-Analysis Protocols on Acupuncture
    Moran, Jose M.
    Romero-Moreno, Maria
    Santillan-Garcia, Azucena
    Herrera-Peco, Ivan
    HEALTHCARE, 2022, 10 (01)