PURPOSE: To investigate the reasons for the removal and/ or exchange of posterior chamber phakic intraocular lenses (PCPIOLs) and the outcomes of these procedures. METHODS: In this retrospective study, PCPIOL implantations performed between January 2015 and June 2023 in a single center were reviewed. The study group consisted of the files of eyes with removed and/or exchanged PCPIOL. Visual acuities, refraction errors, endothelial cell counts, and measurements of the vault before and after exchanges were recorded. Reasons for removal and/or exchange were evaluated. The tuck-and-pull technique was used in all explantations. RESULTS: Twenty-three of 1,490 eyes with PCPIOL implantation required removal and/or exchange. Of the explanted eyes, 17 were implanted with PCPIOLs for myopia (1.21% of all myopic corrections) and 6 were implanted with PCPIOLs for hyperopia (6.59% of all hyperopic corrections). The most common reason for removal and/or exchanges after implantation was inappropriate vault (10 of the 23 total removals and/or exchanges), followed by cataract development (7 of the 23 total removals and/or exchanges). A comparison of the biometric characteristics of eyes with PCPIOL removal and/ or exchange due to inappropriate vault with other PCPIOL implantations showed that anterior chamber depth, PCPIOL length, and white-to-white distance were significantly higher in the group of explanted eyes (P < .05). All eyes with high vault in myopic patients had a 13.2- or 13.7-mm length PCPIOL. CONCLUSIONS: The main reason for PCPIOL removal and/ or exchange is vault values outside the ideal limits and cataract development. Before ordering 13.2- and 13.7-mm long PCPIOLs, biometric data of both eyes and recommended PCPIOL sizes should be carefully reviewed.
引用
收藏
页码:e797 / e803
页数:7
相关论文
共 50 条
  • [41] Rhegmatogenous retinal detachment in phakic eyes after posterior chamber phakic intraocular lens implantation for severe myopia
    Martínez-Castillo, V
    Boixadera, A
    Verdugo, A
    Elíes, D
    Coret, A
    García-Arumí, J
    OPHTHALMOLOGY, 2005, 112 (04) : 580 - 585
  • [42] Posterior chamber silicone phakic intraocular lens
    Marinho, A
    Neves, MC
    Pinto, MC
    Vaz, F
    JOURNAL OF REFRACTIVE SURGERY, 1997, 13 (03): : 219 - 222
  • [43] Clinical Results of Posterior Chamber Phakic Intraocular Lens Implantation in Eyes With Low Anterior Chamber Depth
    Lim, Dong Hui
    Lee, Min Gyu
    Chung, Eui-Sang
    Chung, Tae-Young
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (03) : 447 - 454
  • [44] Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens
    Gargallo-Martinez, Beatriz
    Javier Garcia-Medina, Jose
    Rubio-Velazquez, Elena
    Fernandes, Paulo
    Villa-Collar, Cesar
    Gonzalez-Meijome, Jose M.
    Gutierrez-Ortega, Ramon
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [45] The STAAR posterior chamber phakic intraocular lens
    Zaldivar, R
    Oscherow, S
    Ricur, G
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 237 - 244
  • [46] Optical biometry of eyes corrected by phakic intraocular lenses
    Pitault, G
    Leboeuf, C
    Jardins, SLL
    Auclin, F
    Chong-Sit, D
    Baudouin, C
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (10): : 1052 - 1057
  • [48] FLUOROPHOTOMETRY IN MYOPIC PHAKIC EYES WITH ANTERIOR-CHAMBER INTRAOCULAR LENSES TO CORRECT SEVERE MYOPIA
    PEREZSANTONJA, JJ
    HERNANDEZ, JL
    DELCASTILLO, JMB
    RODRIGUEZBERMEJO, C
    ZATO, MA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (03) : 316 - 321
  • [49] Retinal detachment in phakic eyes with anterior chamber intraocular lenses to correct severe myopia -: Reply
    Ruiz-Moreno, JM
    Alió, JL
    Pérez-Santonja, JJ
    De la Hoz, F
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (03) : 396 - 396
  • [50] POSTERIOR CHAMBER INTRAOCULAR LENSES IN A SERIES OF 75 AUTOPSY EYES .1. LOOP LOCATION
    APPLE, DJ
    PARK, SB
    MERKLEY, KH
    BREMS, RN
    RICHARDS, SC
    LANGLEY, KE
    PIEST, KL
    ISENBERG, RA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (04): : 358 - 362