Assessment for Fire Damage in Concrete Structures with Electrical Resistance Measurement

被引:0
|
作者
Kinose, Toru [1 ]
Imamoto, Kei-Ichi [2 ]
Yoshida, Natsuki [3 ]
Atarashi, Daiki [3 ]
机构
[1] Gen Bldg Res Corp Japan, 5-8-1 Fujishirodai, Suita, Osaka, Japan
[2] Tokyo Univ Sci, Tokyo, Japan
[3] Shimane Univ, Matsue, Shimane, Japan
关键词
Concrete; Fire Damage; High-Temperature Heating; Investigating Method; Electrical Resistance; Moisture Content;
D O I
10.1007/978-3-031-75507-1_16
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
When devising plans for repairing and reinforcing concrete structures after a fire, one must evaluate the effects of heat on concrete. When a fire occurs in a concrete structure, the moisture contained within it evaporates owing to high temperatures. The authors investigated methods to assess the effect of heat by correlating the drying process during a fire with the heating temperature. In this study, a method for evaluating the drying degree of concrete after fire exposure was examined by measuring the electrical resistance, which is closely related to the moisture content of concrete. Initially, a method was investigated to measure the electrical resistance in the depth direction from the surface of fire-damaged concrete. Subsequently, the electrical resistance of the specimens heated to simulate fire conditions was measured, and the relationships among the electrical resistance, moisture content, and heating temperature were compared. Measuring the electrical resistance of the surface of concrete damaged by fire and then comparing it to the resistance of unheated concrete allows one to identify the area that had been heated to 150 degrees C or more and became almost completely dry.
引用
收藏
页码:153 / 162
页数:10
相关论文
共 50 条
  • [21] Electrical resistivity measurement applied to cracking assessment on reinforced concrete structures in civil engineering
    Lataste, JF
    Sirieix, C
    Breysse, D
    Frappa, M
    NDT & E INTERNATIONAL, 2003, 36 (06) : 383 - 394
  • [22] MEASUREMENT OF THE ELECTRICAL-RESISTIVITY OF REINFORCED-CONCRETE STRUCTURES FOR THE ASSESSMENT OF CORROSION RISK
    MILLARD, SG
    HARRISON, JA
    EDWARDS, AJ
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1989, 31 (11): : 617 - 621
  • [23] A NEW QUANTITATIVE METHOD OF ASSESSING FIRE DAMAGE TO CONCRETE STRUCTURES
    NASSIF, AY
    BURLEY, E
    RIGDEN, S
    MAGAZINE OF CONCRETE RESEARCH, 1995, 47 (172) : 271 - 278
  • [24] Assessment of the damage in carbon fiber reinforced concrete by acoustic emission and resistance measurement methods
    Zhao Jiao
    Xu Zhihong
    ENGINEERING STRUCTURAL INTEGRITY: RESEARCH, DEVELOPMENT AND APPLICATION, VOLS 1 AND 2, 2007, : 1493 - 1496
  • [25] Assessment Techniques for the Evaluation of Concrete Structures After Fire
    Annerel, Emmanuel V. R.
    Taerwe, Luc R.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2013, 4 (02) : 123 - 129
  • [26] Damage Evaluation Based on Electrical Resistance Measurement
    Yang, Lijun
    Sun, Binxiang
    Guo, Yimu
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS VII, 2008, 385-387 : 589 - +
  • [27] Application of Electrical Resistance Tomography to Damage Detection in Concrete
    Zhao, Jianyu
    Su, Chenhui
    Ren, Hongwei
    Qin, Lei
    Dong, Biqin
    Xing, Feng
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 4746 - 4749
  • [28] The drilling resistance test for the assessment of fire damaged concrete
    Felicetti, Roberto
    CEMENT & CONCRETE COMPOSITES, 2006, 28 (04): : 321 - 329
  • [29] Electrical Resistance Tomography for Assessment of Cracks in Concrete
    Karhunen, K.
    Seppaenen, A.
    Lehikoinen, A.
    Blunt, J.
    Kaipio, J. P.
    Monteiro, P. J. M.
    ACI MATERIALS JOURNAL, 2010, 107 (05) : 523 - 531
  • [30] Damage assessment through electrical resistance measurement in graphite fiber-reinforced composites