Study on a 20 K two-stage thermally-coupled pulse tube cooler with independent ambient displacers

被引:0
|
作者
Ding, X. P. [1 ,2 ]
Li, Z. K. [1 ,2 ]
Wang, X. T. [1 ]
Zhang, Y. B. [3 ]
Dai, W. [1 ,2 ]
Li, H. B. [3 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Lihan Cryogen Co Ltd, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1088/1757-899X/1301/1/012146
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pulse tube cooler has the advantages of higher reliability and longer MTTF compared to Stirling cooler due to the elimination of moving components at the cold end. Pulse tube cooler working at liquid hydrogen temperatures has already become a strong candidate in sensor cooling, high-temperature superconductivity, etc. However, the efficiency of the pulse tube cooler at liquid hydrogen temperatures remains relatively low. In this paper, a two-stage thermally-coupled Stirling-type pulse tube cooler working at liquid hydrogen temperatures is designed and simulated. The first and second stage use independent ambient displacers as phase shifters. The simulation results show that the pulse tube cooler can reach a higher relative Carnot efficiency due to the improvement of the phase distribution of the whole system by using independent displacers. Meanwhile, the influence of factors such as average pressure and operating frequency on the system performance is also discussed.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Investigation on a two-stage pulse tube cooler at liquid hydrogen temperature using independent displacer phase shifter
    Pang, Xiaomin
    Wang, Hui
    Wang, Xiaotao
    Dai, Wei
    Ma, Suxia
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 156 : 40 - 45
  • [22] GM-type two-stage pulse tube cooler with high efficiency
    Hofmann, A
    Pan, H
    Oellrich, L
    CRYOCOOLERS 11, 2001, : 221 - 227
  • [23] A separate two-stage pulse tube cooler working at liquid helium temperature
    Qiu, LM
    He, YL
    Gan, ZH
    Wan, LH
    Chen, GB
    CHINESE SCIENCE BULLETIN, 2005, 50 (10): : 1030 - 1033
  • [24] A separate two-stage pulse tube cooler working at liquid helium temperature
    QIU Limin
    ChineseScienceBulletin, 2005, (10) : 1030 - 1033
  • [25] Improvement of the two-stage Stirling cooler below 20K
    Yasuda, A.
    Otsuka, K.
    Tsunematsu, S.
    Hiratsuka, Y.
    Kanao, K.
    ADVANCES IN CRYOGENIC ENGINEERING: PROCEEDINGS OF THE CRYOGENIC ENGINEERING CONFERENCE, CEC 2023, 2024, 1301
  • [26] Small scale 4He liquefaction using a two-stage 4 K pulse tube cooler
    Thummes, G
    Wang, C
    Heiden, C
    CRYOGENICS, 1998, 38 (03) : 337 - 342
  • [27] High frequency two-stage pulse tube cryocooler with base temperature below 20 K
    Yang, LW
    Thummes, G
    CRYOGENICS, 2005, 45 (02) : 155 - 159
  • [28] TESTS OF COPPER AND HTS LEADS WITH A TWO-STAGE PULSE TUBE DROP-IN COOLER
    Green, M. A.
    Wang, S. T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 581 - 588
  • [29] A numerical model of a 4K two-stage pulse tube cooler with mixed Eulerian-Lagrangian method
    Ju, YL
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 715 - 722
  • [30] A computational model for two-stage 4K-pulse tube cooler: Part II. Predicted results
    Y. L. Ju
    A. T. A. M. de Waele
    Journal of Thermal Science, 2002, 11 : 74 - 79