Simplified Cluster Voltage Balancing Control Based on Zero-sequence Voltage Injection for Star-connected Cascaded H-bridge STATCOM

被引:1
|
作者
Hu, Kai [1 ]
Zhao, Guoliang [2 ]
Lu, Daorong [1 ]
Lu, Zhengang [2 ]
Xiang, Nianwen [1 ]
Wang, Shulai [1 ]
Lin, Jintian [3 ,4 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei 230009, Peoples R China
[2] Nanjing Normal Univ, Sch Elect & Automat Engn, Nanjing 210023, Peoples R China
[3] State Grid Smart Grid Res Inst SGRI, Beijing 102209, Peoples R China
[4] State Grid Zhejiang Elect Power Res Inst, Power Grid Technol Ctr, Hangzhou 310004, Peoples R China
来源
基金
国家重点研发计划;
关键词
Cluster DC voltage balancing control; DC representation of zero-sequence voltage; star-connected cascaded H-bridge STATCOM; zero-sequence voltage injection; POWER; INVERTER; CAPABILITY; CONVERTER;
D O I
10.17775/CSEEJPES.2022.01700
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system. However, as the zero-sequence voltage is expressed in trigonometric form, traditional control methods involve many complicated operations, such as the square-root, trigonometric operations, and inverse tangent operations. To simplify cluster voltage balancing control, this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable, and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators, rather than being calculated from uneven active powers in traditional controls. This removes all complicated operations. Finally, this paper presents simulation and experimental results for a 400 V/+/- 7.5 kvar star-connected STATCOM, in balanced and unbalanced scenarios, thereby verifying the effectiveness of the proposed control.
引用
收藏
页码:2255 / 2264
页数:10
相关论文
共 50 条
  • [21] A DC-Voltage Control strategy for cascaded H-bridge Converter based STATCOM with Negative Sequence Voltage Injection
    Zhao, Weiming
    Wang, Yong
    Zhao, Bo
    2012 2ND INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2012, : 76 - 79
  • [22] Distributed predictive control for capacitor voltage balancing in a Cascaded H-Bridge Based STATCOM
    Navas-Fonseca, Alex
    Burgos-Mellado, Claudio
    Arias-Esquivel, Yeiner
    Verma, Anant Kumar
    Mora, Andres
    Munoz-Carpintero, Diego
    Cardenas, Roberto
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [23] An Improved Fault Tolerant Technique Based on Zero-Sequence Voltage Injection for Symmetric Cascaded H-bridge Inverter
    Neyshabouri, Yousef
    Farhadi-Kangarlu, Mohammad
    2020 28TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2020, : 781 - 786
  • [24] Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization
    Ji, Zhendong
    Zhao, Jianfeng
    Sun, Yichao
    Yao, Xiaojun
    Zhu, Zean
    JOURNAL OF POWER ELECTRONICS, 2014, 14 (05) : 946 - 956
  • [25] DC voltage balancing for PWM cascaded H-bridge converter based STATCOM
    Barrena, Jon Andoni
    Marroyo, Luis
    Rodriguez, Miguel Angel
    Alonso, Oscar
    Torrealday, Jose Ramon
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1773 - +
  • [26] Analysis of unbalanced clustered voltage and control strategy of clustered voltage balancing for cascaded H-bridge STATCOM
    Yu JIN
    Jianze WANG
    Yiqi LIU
    Xinagyu SAI
    Yanchao JI
    JournalofModernPowerSystemsandCleanEnergy, 2019, 7 (06) : 1697 - 1708
  • [27] Analysis of unbalanced clustered voltage and control strategy of clustered voltage balancing for cascaded H-bridge STATCOM
    Jin, Yu
    Wang, Jianze
    Liu, Yiqi
    Sai, Xinagyu
    Ji, Yanchao
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2019, 7 (06) : 1697 - 1708
  • [28] Control Strategy using zero-sequence for H-bridge STATCOM
    Jie, Zhou
    Yong, Wang
    Bo, Zhao
    Shi Zhiyong
    2012 2ND INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY (CARPI), 2012, : 225 - 228
  • [29] Studies on the Clustered Voltage Balancing Mechanism for Cascaded H-Bridge STATCOM
    Lu, Daorong
    Hu, Haibing
    Xing, Yan
    He, Xiaobin
    Sun, Kai
    Yao, Jianhui
    APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 2194 - 2199
  • [30] Maximum Reactive Power Generation Method Based on Limitation of Output Capacity for Star-Connected Cascaded H-Bridge STATCOM Under Voltage Sag
    Wei, Miaoyu
    Lu, Daorong
    Wu, Tianhong
    Hu, Haibing
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (01) : 635 - 645