Estimation; Electrocardiography; Feature extraction; Training; Biomedical monitoring; Blood pressure; Testing; Standards; Long short term memory; Sensors; Blood pressure (BP) estimation; convolutional neural networks (CNNs); electrocardiogram (ECG); long short-term memory (LSTM); noninvasive monitoring; photoplethysmogram (PPG); NET;
D O I
10.1109/JSEN.2024.3512197
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate and noninvasive blood pressure (BP) monitoring is essential for managing cardiovascular health, yet traditional cuff-based methods are uncomfortable and unsuitable for continuous use. Existing cuffless BP estimation techniques face limitations such as limited feature extraction capabilities, which can result in lower performance, and validation on nonstandard or small datasets, which raises concerns about generalizability. To address these challenges, we propose a novel convolutional neural network (CNN)-long short-term memory (LSTM) architecture that independently processes photoplethysmogram (PPG) and electrocardiogram (ECG) signals through separate CNN layers, enhancing morphological feature extraction. These layers are followed by a multilayer Bi-LSTM network that captures long-term temporal dependencies, improving BP prediction accuracy. Unlike prior studies, we validate our method on the PulseDB dataset, the largest publicly available dataset for BP estimation, comprising cleaned PPG, ECG, and arterial BP (ABP) waveforms from the MIMIC-III and VitalDB databases. Evaluated on data from 3027 individuals using fivefold cross-validation, our model achieved a mean absolute error (MAE) of 5.16 mmHg for systolic BP (SBP) and 3.24 mmHg for diastolic BP (DBP), with consistent performance across various age groups and genders. These results surpassed American National Standards Institute (ANSI)/Association for the Advancement of Medical Instrumentation (AAMI) standards and achieved an "A" grade by British Hypertension Society (BHS) standards, demonstrating the potential of this approach to improve patient comfort and care in diverse clinical and home environments.
引用
收藏
页码:4006 / 4014
页数:9
相关论文
共 45 条
  • [31] Feasibility Study of Dual-PPG Sensors for Blood Velocity and Pressure Estimation
    Han, Ching-Fu
    Hsiao, Chun-Yi
    Lee, Ren-Guey
    Hsiao, Chun-Chieh
    Lin, Robert
    2018 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2018, : 4065 - 4070
  • [32] Estimation of Beat-by-Beat Blood Pressure and Heart Rate From ECG and PPG Using a Fine-Tuned Deep CNN Model
    Yen, Chih-Ta
    Chang, Sheng-Nan
    Liao, Cheng-Hong
    IEEE ACCESS, 2022, 10 : 85459 - 85469
  • [33] Design and validation of dual-point time-differentiated photoplethysmogram (2PPG) wearable for cuffless blood pressure estimation
    Wong, Kei Fong Mark
    Huang, Weiting
    Ee, Dinaa Ying Hui
    Ng, Eddie Yin Kwee
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 253
  • [34] Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM network
    Tanveer, Md. Sayed
    Hasan, Md. Kamrul
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 51 : 382 - 392
  • [35] BLOOD PRESSURE ESTIMATION FROM PPG SIGNALS USING CONVOLUTIONAL NEURAL NETWORKS AND SIAMESE NETWORK
    Schlesinger, Oded
    Vigderhouse, Nitai
    Eytan, Danny
    Moshe, Yair
    2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 1135 - 1139
  • [36] GRU-Based Fusion Models for Enhanced Blood Pressure Estimation From PPG Signals
    Rizal, Syamsul
    Ana Rahma, Yuniarti
    IEEE ACCESS, 2024, 12 : 80317 - 80326
  • [37] Blood Pressure Estimation from PPG Signals Using Deep Residual Network with Transfer Learning
    Koparir, Huseyin Murat
    Arslan, Ozkan
    2023 31ST SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU, 2023,
  • [38] Continuous blood pressure prediction system using Conv-LSTM network on hybrid latent features of photoplethysmogram (PPG) and electrocardiogram (ECG) signals
    Kamanditya, Bharindra
    Fuadah, Yunendah Nur
    Mahardika T., Nurul Qashri
    Lim, Ki Moo
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [39] Cuffless Blood Pressure Estimation Using Features Extracted from Carotid Dual-Diameter Waveforms
    Ramakrishna, Prashanth
    Nabeel, P. M.
    Kiran, Raj, V
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2719 - 2722
  • [40] Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method
    Mousavi, Seyedeh Somayyeh
    Firouzmand, Mohammad
    Charmi, Mostafa
    Hemmati, Mohammad
    Moghadam, Maryam
    Ghorbani, Yadollah
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 47 : 196 - 206