Taylor-Fourier Analysis of Photoplethysmography Signals for Heart Rate Measurement

被引:0
|
作者
Rahbar, Sahar [1 ]
Ferrero, Roberto [1 ]
Pegoraro, Paolo Attilio [2 ]
Toscani, Sergio [3 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool, Merseyside, England
[2] Univ Cagliari, Dept Elect & Elect Engn, Cagliari, Italy
[3] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
关键词
Photoplethysmography (PPG); Biomedical signal processing; Time-domain analysis; Frequency-domain analysis; Fourier transform; Taylor series; TIME;
D O I
10.1109/I2MTC60896.2024.10560902
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photoplethysmography (PPG) is gaining increasing attention for the measurement of heart rate (HR) and heart rate variability (HRV), but the accuracy and reliability of measurement results remain questionable when obtained from wearable devices, prone to recording movement artifacts and other disturbances caused by poor sensor-skin contact. HR and HRV information is typically extracted in the time domain, from the estimation of inter-beat intervals, which can be confidently identified only when the signal is very clean. This paper proposes an alternative time-frequency approach to the HR estimation and to the signal quality assessment, based on the Taylor-Fourier Transform, capable of retrieving time-varying amplitudes and phases of the spectral components in non-sinusoidal, quasiperiodic signals. Preliminary results from a healthy subject show good promise for this method in the identification of disturbances within the signal and in the estimation of the instantaneous HR, at least in clean parts of the signal. A full validation of the proposed method remains outside the scope of this paper, but directions for future research are discussed.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
    Ismail, Shahid
    Akram, Usman
    Siddiqi, Imran
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2021, 2021 (01)
  • [32] Remote Photoplethysmography for Heart Rate and Blood Oxygenation Measurement: A Review
    Pirzada, Pireh
    Wilde, Adriana
    Harris-Birtill, David
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 23436 - 23453
  • [33] Feature-Based Bearing Fault Classification Using Taylor-Fourier Transform
    Avalos-Almazan, Gerardo
    Aguayo-Tapia, Sarahi
    Rangel-Magdaleno, Jose de Jesus
    Arrieta-Paternina, Mario R.
    MACHINES, 2023, 11 (11)
  • [34] Pulse Rate Variability Analysis Using Remote Photoplethysmography Signals
    Yu, Su-Gyeong
    Kim, So-Eui
    Kim, Na Hye
    Suh, Kun Ha
    Lee, Eui Chul
    SENSORS, 2021, 21 (18)
  • [35] Effect of Filtering of Photoplethysmography Signals in Pulse Rate Variability Analysis
    Mejia-Mejia, Elisa
    May, James M.
    Kyriacou, Panayiotis A.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5500 - 5503
  • [36] Taylor-Fourier PMU on a Real-Time Simulator: Design, Implementation and Characterization
    Frigo, G.
    Derviskadic, A.
    Zuo, Y.
    Bach, A.
    Paolone, M.
    2019 IEEE MILAN POWERTECH, 2019,
  • [37] Dynamic Phasors Estimation Based on Taylor-Fourier Expansion and Gram Matrix Representation
    Petrovic, Predrag
    Damljanovic, Nada
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [38] The Use of Multichannel Photoplethysmography for the Analysis of Heart Rate Variability
    Peter, L.
    Ladrova, M.
    Cerny, M.
    Bryjova, I.
    EMBEC & NBC 2017, 2018, 65 : 831 - 834
  • [39] Analysis of Heart Rate Variability from Multichannel Photoplethysmography
    Peter, Lukas
    Ladrova, Martina
    Bryjova, Iveta
    Cerny, Martin
    NEW TRENDS IN INTELLIGENT SOFTWARE METHODOLOGIES, TOOLS AND TECHNIQUES, 2017, 297 : 217 - 225
  • [40] Heart rate variability estimation in photoplethysmography signals using Bayesian learning approach
    Alqaraawi, Ahmed
    Alwosheel, Ahmad
    Alasaad, Amr
    HEALTHCARE TECHNOLOGY LETTERS, 2016, 3 (02) : 136 - 142