The role of renal dual-energy computed tomography in exploring the gouty kidney: the RENODECT study

被引:0
|
作者
Pascart, Tristan [1 ]
Dauphin, Elie [1 ]
Yokose, Chio [2 ]
Jauffret, Charlotte [1 ]
Pacaud, Aurore [1 ]
Laurent, Victor [1 ]
Ducoulombier, Vincent [1 ]
Choi, Hyon K. [2 ]
Budzik, Jean-Francois [3 ]
机构
[1] Lille Catholic Univ, St Philibert Hosp, Dept Rheumatol, ETHICS Lab, Lille, EA, France
[2] Harvard Med Sch, Massachusetts Gen Hosp, Boston, MA USA
[3] Lille Catholic Univ, St Philibert Hosp, Dept Med Imaging, ETHICS Lab, Lille, EA, France
关键词
Gout; chronic kidney disease; dual-energy computed tomography; monosodium urate; uric acid;
D O I
10.1080/07853890.2025.2458783
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveThe objective of this study was to explore the ability of dual-energy computed tomography (DECT) to detect monosodium urate (MSU) crystal deposits in the kidneys and renal artery walls, and uric acid urolithiasis, in patients with gout and chronic kidney disease (CKD).MethodsPatients with gout and with stage 2-4 CKD were prospectively included in this cross-sectional study. Patients underwent renal, knee and feet DECT scans. Renal DECT scans were read for MSU-coded lesions in the kidneys, renal artery walls, and urinary tract using different post-processing settings. Characteristics of patients with and without DECT-positive lesions were compared, and the DECT parameters of these lesions were measured.ResultsA total of 27/31 patients with had renal DECT scans and were included in the analysis (23/27 men, mean (standard deviation) 73 (9) years old, mean eGFR 45.3 mL/min/1.73 m2 (21.0), volumes of MSU in the knees and feet ranging from 0.11 to 475.0 cm3). None of the patients exhibited deposition of MSU crystals in the kidneys. One case of calyceal calculi and one case of ureterolithiasis were observed, wrongly coded as MSU in default post-processing settings for gout but identified as uric acid in the "kidney stone" settings. Five patients had MSU-coded plaques in the renal arteries, which had DECT parameters consistent with early calcified plaques rather than MSU, and had no association with volumes of peripheral MSU deposition.ConclusionDECT is unable to detect genuine monosodium urate crystal deposits in kidneys and renal artery walls, and but can characterize chronic asymptomatic urolithiasis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Clinical Images: Detection of gouty arthritis in the atlantoaxial joint using dual-energy computed tomography
    Kim, Hae-Rim
    Lee, Jung Hwa
    Oh, Jeeyoung
    Kim, Na Ra
    Lee, Sang-Heon
    ARTHRITIS AND RHEUMATISM, 2012, 64 (04): : 1290 - 1290
  • [22] Dual-energy computed tomography angiography for evaluating the renal vascular variants
    TAO Xiao-feng
    ZHU Jing-qi
    WU Ying-wei
    TANG Guang-yu
    SHI Yu-zhen
    ZHANG Lei
    LIN Yi
    WANG Zhong-qiu
    中华医学杂志(英文版), 2013, 126 (04) : 650 - 654
  • [23] In vivo determination of renal stone composition with dual-energy computed tomography
    Corbett, John-Henry
    Harmse, Werner S.
    SA JOURNAL OF RADIOLOGY, 2014, 18 (01):
  • [24] Dual-energy computed tomography angiography for evaluating the renal vascular variants
    Tao Xiao-feng
    Zhu Jing-qi
    Wu Ying-wei
    Tang Guang-yu
    Sri Yu-zhen
    Zhang Lei
    Lin Yi
    Wang Zhong-qiu
    CHINESE MEDICAL JOURNAL, 2013, 126 (04) : 650 - 654
  • [25] Dual-Energy Computed Tomography Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography
    Parakh, Anushri
    Macri, Francesco
    Sahani, Dushyant
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 601 - +
  • [26] GOUT AT THE SPINE: A RETROSPECTIVE STUDY WITH DUAL-ENERGY COMPUTED TOMOGRAPHY
    Chotard, E.
    Sverzut, J. M.
    Liote, F.
    Bardin, T.
    Ea, H-K.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 367 - 368
  • [27] The Role of Dual-Energy Computed Tomography in Assessment of Abdominal Oncology and Beyond
    Morgan, Desiree E.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 565 - +
  • [28] Dual-energy Computed Tomography (DECT) Scan for Determination of Renal Stone Composition: A Phantom Study
    Sheikhi, Mahboobeh
    Sina, Sedigheh
    Karimipourfard, Mehrnoosh
    IRANIAN JOURNAL OF RADIOLOGY, 2023, 20 (03)
  • [29] The Role of Dual-Energy Computed Tomography in Locating Gastrointestinal Tract Perforations
    Bas, Serap
    Zarbaliyev, Elbrus
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (05)
  • [30] Dual-energy computed tomography diagnostics for gout
    Rech, H. J.
    Cavallaro, A.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (07): : 580 - 588