Characterization of Additively Manufactured Titanium-Based Alloy with a Micro-Arc Oxidation Coating and Overlying Polyurethane Layer

被引:0
|
作者
Lien, Po-Wei [1 ]
Jian, Shun-Yi [1 ,2 ]
Hung, Jung-Chou [3 ]
Yang, Po-Jen [3 ]
Lin, Hsuan-Han [3 ]
Chu, Kuan-Yu [3 ]
Kao, Chun-Hsiang [4 ]
Ferng, Yi-Cherng [4 ]
Huang, Sheng-Hsiang [4 ]
Jen, Kuo-Kuang [4 ]
机构
[1] Ming Chi Univ Technol, Dept Mat Engn, New Taipei City 24301, Taiwan
[2] Ming Chi Univ Technol, Ctr Plasma & Thin Film Technol, New Taipei 243303, Taiwan
[3] Natl Cent Univ, Dept Mech Engn, Taoyuan 32001, Taiwan
[4] Natl Chung Shan Inst Sci & Technol, Missile & Rocket Syst Res Div, Taoyuan City 32546, Taiwan
来源
COATINGS | 2025年 / 15卷 / 02期
关键词
titanium alloys; microarc oxidation coatings; polyurethane; corrosion resistance; microstructure; CORROSION-RESISTANCE;
D O I
10.3390/coatings15020137
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Titanium alloys are widely used in the aerospace, automotive, chemical, and biomedical industries due to their excellent corrosion resistance, mechanical properties, and biocompatibility. However, the surface properties of titanium alloys are often insufficient to meet the increasingly complex requirements of certain applications. Therefore, enhancing the surface performance of titanium alloys in physiological environments has become a key focus of research. In this study, a porous oxide layer was generated on the surface of a titanium substrate through micro-arc oxidation (MAO). This layer served as an intermediate layer for a subsequently deposited polyurethane (PU) coating, providing a strong foundation for adhesion. The high porosity of the MAO layer not only facilitated the adhesion of the PU coating but also protected the titanium alloy, further enhancing its corrosion resistance. The surface microstructure after MAO treatment and the morphological changes after application of the PU coating were characterized using scanning electron microscopy. The PU layer uniformly covered the surface of the MAO layer, significantly improving the smoothness and uniformity of the surface. The increase in surface smoothness due to the PU coating on top of the MAO layer was verified through white light interferometry. Additionally, surface hydrophobicity was assessed through water contact angle measurements. The PU layer over the MAO coating significantly enhanced the hydrophobicity of the titanium alloy's surface, which is crucial for reducing biofouling and improving the effectiveness of biomedical implants. Finally, electrochemical analysis was conducted to study the corrosion resistance of the titanium alloy after MAO and PU treatment. The titanium alloy with an MAO-PU composite coating exhibited the highest corrosion resistance. The findings revealed that the combination of the MAO layer and PU coating provides an excellent multifunctional protective layer for titanium alloys, not only enhancing their durability but also their ability to adapt to physiological and harsh environments.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Advancing titanium-based surfaces via micro-arc oxidation with solid substance incorporation: A systematic review
    Ogur, Ezgi
    Alves, Alexandra C.
    Toptan, Fatih
    MATERIALS TODAY COMMUNICATIONS, 2024, 41
  • [22] Effect of Content of Graphene on Corrosion Behavior of Micro-Arc Oxidation Coating on Titanium Alloy Drill Pipe
    Chen, Xiaowen
    Liao, Dandan
    Zhang, Defen
    Jiang, Xuan
    Zhao, Pengfei
    Xu, Ruosi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (01): : 710 - 721
  • [23] Tribological Properties of the Micro-arc Oxidation Scale of Al Coating on TC4 Titanium Alloy
    Fu, Jun-tao
    Yang, Lian
    Liu, Wei-jie
    Bu, Tong
    Chen, En
    Feng, Chang-jie
    INTERNATIONAL CONFERENCE ON MATERIALS, MANUFACTURING AND MECHANICAL ENGINEERING (MMME 2016), 2016, : 69 - 72
  • [24] Assessment of osteoinduction using a porous hydroxyapatite coating prepared by micro-arc oxidation on a new titanium alloy
    Jing, Wensen
    Zhang, Minghua
    Jin, Lei
    Zhao, Jian
    Gao, Qing
    Ren, Min
    Fan, Qingyu
    INTERNATIONAL JOURNAL OF SURGERY, 2015, 24 : 51 - 56
  • [25] Alumina coating formed on medical NiTi alloy by micro-arc oxidation
    Xu, J. L.
    Liu, F.
    Wang, F. P.
    Zhao, L. C.
    MATERIALS LETTERS, 2008, 62 (25) : 4112 - 4114
  • [26] Mechanical Properties of Micro-arc Oxidation Coating on Titanium and Large Plastic Deformed Titanium
    Xu Xiaojing
    Xu Lin
    Niu Xiaoya
    Ding Jianning
    Zhu Lihua
    RARE METAL MATERIALS AND ENGINEERING, 2017, 46 (02) : 473 - 478
  • [27] Formation Mechanism of the Micro-arc Oxidation Ceramic Coating on NiTi Alloy
    Xu Jilin
    Liu Fu
    Luo Junming
    Wang Fuping
    RARE METAL MATERIALS AND ENGINEERING, 2012, 41 (10) : 1770 - 1774
  • [28] Effect of Discharge Energy on Micro-Arc Oxidation Coating of Zirconium Alloy
    Wang, Wei
    Lv, Kai
    Du, Zhaoxin
    Chen, Weidong
    Pang, Zhi
    MATERIALS, 2024, 17 (13)
  • [29] Preparation and activation of micro-arc oxidation films on a TLM titanium alloy
    Yu, S.
    Yu, Z. T.
    BIOMEDICAL MATERIALS, 2008, 3 (04)
  • [30] Study on preparation and properties of micro-arc oxidation biofilm on titanium alloy
    Chen H.
    Ding J.
    Chen Y.-N.
    Xing Y.-Z.
    Hao J.-M.
    Surface Technology, 2021, 50 (03): : 45 - 50