Characterization of Additively Manufactured Titanium-Based Alloy with a Micro-Arc Oxidation Coating and Overlying Polyurethane Layer

被引:0
|
作者
Lien, Po-Wei [1 ]
Jian, Shun-Yi [1 ,2 ]
Hung, Jung-Chou [3 ]
Yang, Po-Jen [3 ]
Lin, Hsuan-Han [3 ]
Chu, Kuan-Yu [3 ]
Kao, Chun-Hsiang [4 ]
Ferng, Yi-Cherng [4 ]
Huang, Sheng-Hsiang [4 ]
Jen, Kuo-Kuang [4 ]
机构
[1] Ming Chi Univ Technol, Dept Mat Engn, New Taipei City 24301, Taiwan
[2] Ming Chi Univ Technol, Ctr Plasma & Thin Film Technol, New Taipei 243303, Taiwan
[3] Natl Cent Univ, Dept Mech Engn, Taoyuan 32001, Taiwan
[4] Natl Chung Shan Inst Sci & Technol, Missile & Rocket Syst Res Div, Taoyuan City 32546, Taiwan
来源
COATINGS | 2025年 / 15卷 / 02期
关键词
titanium alloys; microarc oxidation coatings; polyurethane; corrosion resistance; microstructure; CORROSION-RESISTANCE;
D O I
10.3390/coatings15020137
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Titanium alloys are widely used in the aerospace, automotive, chemical, and biomedical industries due to their excellent corrosion resistance, mechanical properties, and biocompatibility. However, the surface properties of titanium alloys are often insufficient to meet the increasingly complex requirements of certain applications. Therefore, enhancing the surface performance of titanium alloys in physiological environments has become a key focus of research. In this study, a porous oxide layer was generated on the surface of a titanium substrate through micro-arc oxidation (MAO). This layer served as an intermediate layer for a subsequently deposited polyurethane (PU) coating, providing a strong foundation for adhesion. The high porosity of the MAO layer not only facilitated the adhesion of the PU coating but also protected the titanium alloy, further enhancing its corrosion resistance. The surface microstructure after MAO treatment and the morphological changes after application of the PU coating were characterized using scanning electron microscopy. The PU layer uniformly covered the surface of the MAO layer, significantly improving the smoothness and uniformity of the surface. The increase in surface smoothness due to the PU coating on top of the MAO layer was verified through white light interferometry. Additionally, surface hydrophobicity was assessed through water contact angle measurements. The PU layer over the MAO coating significantly enhanced the hydrophobicity of the titanium alloy's surface, which is crucial for reducing biofouling and improving the effectiveness of biomedical implants. Finally, electrochemical analysis was conducted to study the corrosion resistance of the titanium alloy after MAO and PU treatment. The titanium alloy with an MAO-PU composite coating exhibited the highest corrosion resistance. The findings revealed that the combination of the MAO layer and PU coating provides an excellent multifunctional protective layer for titanium alloys, not only enhancing their durability but also their ability to adapt to physiological and harsh environments.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Biotribological behaviors of micro-arc oxidation ceramic layer on titanium alloy
    School of Materials Science and Engineering, Jiangsu University of Science and Technology, Zhenjiang, China
    Cailiao Rechuli Xuebao, 11 (162-166):
  • [2] Preparation and Characterization of Micro-Arc Oxidation Coating and Carbon Film on Titanium
    Yang, Xiaokang
    Luo, Binli
    Cai, Jun
    Shuang, Yixiang
    Wang, Kuaishe
    Xiyou Jinshu Cailiao Yu Gongcheng/Rare Metal Materials and Engineering, 2020, 49 (08): : 2875 - 2879
  • [3] Preparation and Characterization of Micro-Arc Oxidation Coating and Carbon Film on Titanium
    Yang Xiaokang
    Luo Binli
    Cai Jun
    Shuang Yixiang
    Wang Kuaishe
    RARE METAL MATERIALS AND ENGINEERING, 2020, 49 (08) : 2875 - 2879
  • [4] Surface Modification of Additively Fabricated Titanium-Based Implants by Means of Bioactive Micro-Arc Oxidation Coatings for Bone Replacement
    Kozelskaya, Anna I. I.
    Rutkowski, Sven
    Frueh, Johannes
    Gogolev, Aleksey S. S.
    Chistyakov, Sergei G. G.
    Gnedenkov, Sergey V. V.
    Sinebryukhov, Sergey L. L.
    Frueh, Andreas
    Egorkin, Vladimir S. S.
    Choynzonov, Evgeny L. L.
    Buldakov, Mikhail
    Kulbakin, Denis E. E.
    Bolbasov, Evgeny N. N.
    Gryaznov, Anton P. P.
    Verzunova, Ksenia N. N.
    Apostolova, Margarita D. D.
    Tverdokhlebov, Sergei I. I.
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (04)
  • [5] Effect of Heat Treatment on Characteristics of Coating on Micro-arc Oxidation β Titanium Alloy
    Lv Kai
    Du Zhaoxin
    Liu Xiangdong
    Fu Junsong
    Chi Bo
    RARE METAL MATERIALS AND ENGINEERING, 2016, 45 (12) : 3290 - 3294
  • [6] Formation of β-tricalcium phosphate coating layer on titanium via micro-arc oxidation
    Shin, K. R.
    Yoon, S. I. Il
    Yang, H. W.
    Ko, Y. G.
    Shin, D. H.
    MATERIALS RESEARCH INNOVATIONS, 2014, 18 : 997 - 1000
  • [7] Micro-arc oxidation of β-titanium alloy: Structural characterization and osteoblast compatibility
    Chen, Hsien-Te
    Hsiao, Ching-Hung
    Long, Han-Yun
    Chung, Chi-Jen
    Tang, Chih-Hsin
    Chen, Keh-Chang
    He, Ju-Liang
    SURFACE & COATINGS TECHNOLOGY, 2009, 204 (6-7): : 1126 - 1131
  • [8] Improving corrosion resistance of additively manufactured nickel–titanium biomedical devices by micro-arc oxidation process
    Amir Dehghanghadikolaei
    Hamdy Ibrahim
    Amirhesam Amerinatanzi
    Mahdi Hashemi
    Narges Shayesteh Moghaddam
    Mohammad Elahinia
    Journal of Materials Science, 2019, 54 : 7333 - 7355
  • [9] SLM Magnesium Alloy Micro-Arc Oxidation Coating
    Yue, Xuejie
    Xu, Kangning
    Wang, Shuyi
    Liu, Hengyan
    Guo, Shiyue
    Zhao, Rusheng
    Xu, Gaopeng
    Wang, Hao
    Yue, Xuezheng
    MATERIALS, 2024, 17 (20)
  • [10] Review of Antibacterial Activity of Titanium-Based Implants' Surfaces Fabricated by Micro-Arc Oxidation
    He, Xiaojing
    Zhang, Xiangyu
    Wang, Xin
    Qin, Lin
    COATINGS, 2017, 7 (03):