Coronal preflaring's influence on the accuracy of root canal length determination by electronic apex locators

被引:0
|
作者
Batista, Larissa C. Novaes [1 ]
Janini, Ana Cristina Padilha [2 ]
Marciano, Marina A. [2 ]
Guimaraes, Tatiany G. F. Araujo
Guimaraes, Bruno Martini [1 ]
机构
[1] Univ Fed Alfenas, UNIFAL MG, Alfenas, MG, Brazil
[2] Univ Estadual Campinas, Fac Odontol Piracicaba, Piracicaba, Brazil
关键词
Cervical preflaring; Electronic apex locators; Root canal preparation; FORAMEN; DISTANCE; SIZE;
D O I
10.24873/j.rpemd.2024.10.1230
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the influence of preflaring using LA Axxess and ProTaper Shaping files on the accuracy of Root ZX mini, Mini Apex Locator, and Propex II electronic apex locators (EALs). Methods: Thirty mandibular incisors were accessed, and their root canal length (RCL) was determined with the aid of a stereomicroscope. Then, the specimens were randomly assigned into two groups according to the preflaring instrument: G1- LA Axxess; G2- ProTaper Shaping files. The root canal length was determined in the alginate model by EALs before and after preflaring. Data were classified as accurate (<= 0.5 mm) or inaccurate (> 0.5 mm or beyond the root canal length). McNemar's test was used to detect differences in the EALs' accuracy before and after preflaring, and Cochran's Q test was applied to detect differences in accuracy between the EALs. Results: McNemar's test identified differences in precision in the Propex II and Mini Apex Locator, with significantly increased accuracy after preflaring with ProTaper files. Cochrans' Q test showed no differences between EALs' accuracy (p>.05). Conclusions: Preflaring procedures increased accurate measurements for all the EALs, with statistical differences for Propex II and Mini Apex Locator when ProTaper instruments were used. All EALs showed similar accuracy. (Rev Port Estomatol Med Dent Cir Maxilofac. 2023;65(3):115-120) (c) 2024 Sociedade Portuguesa de Estomatologia e Medicina Dentaria. Published by SPEMD. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [31] The accuracy of electronic apex locators for determining working length: An in vitro study with artificial teeth
    Bernardo, Raquel C. F. D.
    Alves, Louise S.
    Bruno, Adilia M., V
    Coutinho, Thais M. C.
    Gusman, Heloisa
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (02) : 217 - 221
  • [32] An ex vivo comparison of working length determination by 3 electronic apex locators
    Pascon, Elizeu Alvaro
    Marrelli, Massimo
    Congi, Orsola
    Ciancio, Rosetta
    Miceli, Federica
    Versiani, Marco Aurelio
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : E147 - E151
  • [33] In vitro evaluation of the accuracy of three electronic apex locators
    Lucena-Martín, C
    Robles-Gijón, V
    Ferrer-Luque, M
    de Mondelo, JMNR
    JOURNAL OF ENDODONTICS, 2004, 30 (04) : 231 - 233
  • [34] Use of electronic apex locators may improve determination of working lengthQuestion: Are electronic apex locators (EALs) accurate?
    Isabel Mello
    Evidence-Based Dentistry, 2014, 15 (4) : 120 - 120
  • [35] Accuracy of four electronic apex locators:: an in vitro evaluation
    De Moor, RJG
    Hommez, GMG
    Martens, LC
    De Boever, JG
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1999, 15 (02): : 77 - 82
  • [36] Accuracy of two electronic apex locators in primary teeth
    Bolan, Michele
    de Carvalho Rocha, Maria Jose
    ENDO-ENDODONTIC PRACTICE TODAY, 2010, 4 (01): : 49 - 54
  • [37] In vivo comparison of the accuracy of two electronic apex locators
    Silveira, Luiz F. M.
    Petry, Fernanda V.
    Martos, Josue
    Neto, Joao B. C.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (02) : 70 - 72
  • [38] Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An In Vitro Comparative Study
    Yahya, Eman M.
    Alchalabi, Ashraf S.
    Alkhalidi, Emad Farhan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2024, 14 (03): : 211 - 217
  • [39] Effects of different irrigation solutions on the accuracy of electronic apex locators in curved and straight root canals
    Tekinarslan, Dide
    Erkal, Damla
    Pehlivan, Burcu
    Unal, Elif
    Kayar, Goknur
    Koc, Simay
    Er, Kursat
    GIORNALE ITALIANO DI ENDODONZIA, 2023, 37 (01): : 54 - 61
  • [40] Determination of Working Length with Three Different Apex Locators
    Kqiku, Lumnije
    Hoxha, Veton
    Stadtler, Peter
    ACTA STOMATOLOGICA CROATICA, 2007, 41 (01) : 49 - 56