Point-of-Care Tests for Preeclampsia: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies

被引:0
|
作者
Elbarbary, Nouran [1 ]
Pritsini, Filippa [2 ]
Kazi, Ayisha [1 ]
Wang, Chao [3 ]
Thilaganathan, Baskaran [1 ]
Bhide, Amarnath [1 ]
机构
[1] St Georges Univ Hosp, Fetal Med Unit, London, England
[2] Kings Coll Univ Hosp, Obstet & Gynaecol Dept, LONDON, England
[3] Kingston Univ, Fac Hlth Sci Social Care & Educ, London, England
关键词
glycosylated fibronectin; point of care; preeclampsia; PLACENTAL GROWTH-FACTOR; ANGIOGENIC FACTORS; WOMEN; SPECIFICITY; SENSITIVITY; MODEL;
D O I
10.1111/1471-0528.18040
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BackgroundPreeclampsia is a common condition associated with significant maternal and foetal complications. The diagnosis of preeclampsia is based on clinical criteria, with recent introduction of angiogenic markers as an aid to clinical triage. Several biomarkers are now available in a point-of-care test format, which provide swift results to support clinical decision-making.ObjectivesTo determine sensitivity and specificity of available point-of-care tests used for preeclampsia prediction.Search StrategySystematic searches of databases (PubMed/Medline, Ovid Embase) from inception till May 2024 were done to identify relevant studies. Selection criteria: we included studies reporting on the diagnostic test accuracy of any point-of-care test for short-term prediction of preeclampsia in the second or third trimester.Data Collection and AnalysisData were extracted using pre-designed template, and statistical analysis was performed to pool sensitivity and specificity and a hierarchal summary receiver operating characteristic curve model was used. Quality of included studies and risk of bias were assessed following the QUADAS-2 tool.Main ResultsWe identified 17 studies that met the inclusion criteria, six of which described the use of glycosylated fibronectin, five with Congo red, two with placental growth factor (PlGF) and one study each investigated nephrin, misfolded protein, CD44/FKBPL ratio and inositol phosphoglycan-P. Meta-analysis was possible only for glycosylated fibronectin with a pooled sensitivity of 0.80 (95% CI: 0.51-0.94) and a specificity of 0.84 (95% CI: 0.71-0.93). Five studies were included in meta-analysis, all of which had a low risk of bias on the QUADAS assessment.ConclusionsThese findings suggest that the point-of-care glycosylated fibronectin testing might be beneficial in clinical triage for preeclampsia in an at-risk population.
引用
收藏
页码:414 / 425
页数:12
相关论文
共 50 条
  • [31] Accuracy of Point-of-care Ultrasonography for Diagnosing Acute Appendicitis: A Systematic Review and Meta-analysis
    Fields, J. Matthew
    Davis, Joshua
    Alsup, Carl
    Bates, Amanda
    Au, Arthur
    Adhikari, Srikar
    Farrell, Isaac
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (09) : 1124 - 1136
  • [32] Relative diagnostic accuracy of point-of-care tests to rule-in Dirofilaria immitis infection in clinically suspect dogs: A systematic review and meta-analysis
    Atkinson, Peter J.
    O'Handley, Ryan
    Nielsen, Torben
    Caraguel, Charles G. B.
    PREVENTIVE VETERINARY MEDICINE, 2023, 217
  • [33] Diagnostic accuracy of rapid point-of-care tests for diagnosis of current SARS-CoV-2 infections in children: a systematic review and meta-analysis
    Fujita-Rohwerder, Naomi
    Beckmann, Lars
    Zens, Yvonne
    Verma, Arpana
    BMJ EVIDENCE-BASED MEDICINE, 2022, 27 (05) : 274 - 287
  • [34] Diagnostic accuracy of point-of-care tests in acute community-acquired lower respiratory tract infections. A systematic review and meta-analysis
    Gentilotti, Elisa
    De Nardo, Pasquale
    Cremonini, Eleonora
    Gorska, Anna
    Mazzaferri, Fulvia
    Canziani, Lorenzo Maria
    Hellou, Mona Mustafa
    Olchowski, Yudith
    Poran, Itamar
    Leeflang, Mariska
    Villacian, Jorge
    Goossens, Herman
    Paul, Mical
    Tacconelli, Evelina
    CLINICAL MICROBIOLOGY AND INFECTION, 2022, 28 (01) : 13 - 22
  • [35] Diagnostic Accuracy of Portable, Handheld Point-of-Care Tests vs Laboratory-Based Bilirubin Quantification in Neonates A Systematic Review and Meta-analysis
    Westenberg, Lauren E. H.
    Been, Jasper V.
    Willemsen, Sten P.
    Vis, Jolande Y.
    Tintu, Andrei N.
    Bramer, Wichor M.
    Dijk, Peter H.
    Steegers, Eric A. P.
    Reiss, Irwin K. M.
    Hulzebos, Christian V.
    JAMA PEDIATRICS, 2023, 177 (05) : 479 - 488
  • [36] Diagnostic accuracy of tests for leprosy: a systematic review and meta-analysis
    Gurung, P.
    Gomes, C. M.
    Vernal, S.
    Leeflang, M. M. G.
    CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (11) : 1315 - 1327
  • [37] Diagnostic accuracy of point-of-care natriuretic peptide testing for chronic heart failure in ambulatory care: systematic review and meta-analysis
    Taylor, Kathryn S.
    Verbakel, Jan Y.
    Feakins, Benjamin G.
    Price, Christopher P.
    Perera, Rafael
    Bankhead, Clare
    Pluddemann, Annette
    BMJ-BRITISH MEDICAL JOURNAL, 2018, 361
  • [38] Diagnostic accuracy of salivary active matrix metalloproteinase (aMMP)-8 point-of-care test for detecting periodontitis in adults: A systematic review and meta-analysis
    Wei, Shimin
    Lin, Tingting
    Saenz-Ravello, Gustavo
    Gao, Hanqi
    Zhang, Yong
    Tonetti, Maurizio S.
    Deng, Ke
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2024, 51 (08) : 1093 - 1108
  • [39] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [40] Diagnostic Accuracy of History, Physical Examination, Laboratory Tests, and Point-of-care Ultrasound for Pediatric Acute Appendicitis in the Emergency Department: A Systematic Review and Meta-analysis
    Benabbas, Roshanak
    Hanna, Mark
    Shah, Jay
    Sinert, Richard
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (05) : 523 - 551