Radiation dose to health care workers measured by thermoluminescent dosimetry

被引:0
|
作者
Alakhras, M. [1 ]
Al-Mousa, D. S. [1 ,2 ]
Al Mohammad, B. [1 ]
Kleib, I. [1 ]
机构
[1] Jordan Univ Sci & Technol, Fac Appl Med Sci, Irbid, Jordan
[2] Charles Sturt Univ, Sch Dent & Hlth Sci, Wagga Wagga, NSW, Australia
关键词
MEDICAL WORKERS; EXPOSURES; RADIOLOGY; HOSPITALS; PAKISTAN;
D O I
10.1016/j.crad.2024.09.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate radiation dose among physicians, nurses, nuclear medicine (NM) technicians, and radiographers at a single institution and to compare the difference in the measured dose during COVID-19 with other periods. MATERIALS AND METHODS: A retrospective analysis of the occupational radiation doses received by all workers in diagnostic radiography and NM departments at a single institution during a 5-year period (2018-2022) was performed. Dose measurements were recorded for 94 radiology personnel: radiographers, NM technicians, physicians, and nurses. In addition to descriptive statistics, the Mann-Whitney U-test was used to compare the average annual effective dose between male and female workers and between the periods before and during COVID19. Kruskal-Wallis test was used to compare effective radiation doses from different quadrants. RESULTS: The annual average effective doses were found to be between 0.58 and 0.72 mSv for males and 0.68 and 0.85 mSv for females. All radiographers, 86% of nurses, and 69% of physicians have received annual average effective doses below 0.99 mSv. The average annual effective doses for all radiation workers were similar in the period before COVID-19 when compared to the period during COVID-19 except for nurses who had significantly lower (P<0.05) doses before COVID-19. CONCLUSION: The average annual effective doses of radiation workers during 2018-2022 were well below the annual dose limit. A relatively higher average effective dose was received among NM technicians compared with other radiation occupational workers. While the caseload during the COVID-19 pandemic was lower due to government policies, the radiation dose to healthcare workers during the pandemic was similar to that before the pandemic. (c) 2024 The Royal College of Radiologists. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] APPLICATION OF THERMOLUMINESCENT DOSIMETRY TO VARIOUS ASPECTS OF HEALTH PHYSICS
    MASON, EW
    HARRISON, NT
    LINSLEY, GS
    HEALTH PHYSICS, 1970, 19 (01): : 94 - +
  • [22] Optimization of magnesium borate thermoluminescent material for radiation protection dosimetry
    Prokic, MS
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D296 - D298
  • [23] THERMOLUMINESCENT DOSIMETRY FOR RADIATION EXPOSURE OF BREAST DURING FILM AND XEROMAMMOGRAPHY
    SABEL, M
    RUFF, A
    WEISHAAR, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1978, 128 (05): : 616 - 622
  • [24] Radiation protection in CT pelvis in Fantoma Rando by thermoluminescent dosimetry
    Madrid-Gonzalez, O. A.
    Rivera-Montalvo, T.
    Azorin-Nieto, J.
    APPLIED RADIATION AND ISOTOPES, 2012, 71 : 40 - 43
  • [25] IN-VIVO THERMOLUMINESCENT DOSIMETRY IN CLINICAL RADIATION-THERAPY
    SEYDEL, HG
    CASTRO, VG
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 677 - &
  • [26] RADIATION-DOSIMETRY UTILIZING THERMOLUMINESCENT PEAK TEMPERATURE MEASUREMENTS
    STOEBE, TG
    ZINIKER, WM
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (03): : 308 - &
  • [27] Dose rate constant of a Cesium-131 interstitial brachytherapy seed measured by thermoluminescent dosimetry and gamma-ray spectrometry
    Chen, Z
    Bongiorni, P
    Nath, R
    MEDICAL PHYSICS, 2005, 32 (11) : 3279 - 3285
  • [28] Operational comparison of bubble dosimetry with albedo thermoluminescent dosimetry for a selected group of 238Pu workers
    Romero, LL
    Hoffman, JM
    Foltyn, EM
    Buhl, TE
    HEALTH PHYSICS, 1999, 77 (02): : S9 - S17
  • [29] Dose optimization of total or partial skin electron irradiation by thermoluminescent dosimetry
    Schuettrumpf, Lars
    Neumaier, Klement
    Maihoefer, Cornelius
    Niyazi, Maximilian
    Ganswindt, Ute
    Li, Minglun
    Lang, Peter
    Reiner, Michael
    Belka, Claus
    Corradini, Stefanie
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (05) : 444 - 453
  • [30] Percentage depth dose evaluation in heterogeneous media using thermoluminescent dosimetry
    da Rosa, L. A. R.
    Cardoso, S. C.
    Campos, L. T.
    Alves, V. G. L.
    Batista, D. V. S.
    Facure, A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 117 - 127