Layer-by-layer self-assembled poly(diallyldimethylammonium chloride)/ cyclodextrin composite materials for the electrochemical detection of paracetamol

被引:0
|
作者
Liu, Yuqiong [1 ]
Yang, Ruirui [1 ]
Zhao, Mengjia [1 ]
Guo, Haochang [1 ]
Liu, Yuqi [2 ]
Yan, Haiyan [2 ]
Liu, Zhenguo [1 ,3 ,4 ]
机构
[1] Luoyang Ship Mat Res Inst, Luoyang 471023, Henan, Peoples R China
[2] Xian Technol Univ, Sch Mat & Chem Engn, Shaanxi Key Lab Photoelect Funct Mat & Devices, Xian 710021, Shaanxi, Peoples R China
[3] Henan Univ, Sch Flexible Elect SoFE, Zhengzhou 450046, Peoples R China
[4] Henan Univ, Henan Inst Flexible Elect HIFE, Zhengzhou 450046, Henan, Peoples R China
来源
关键词
Electrochemical sensor; Host-guest interactions; Analgesic detection; Nanoscale film; Pharmaceutical analysis; PASTE ELECTRODE; URIC-ACID; PERFORMANCE; DOPAMINE; SENSOR;
D O I
10.1016/j.ijoes.2024.100878
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This study reports the development of a sensitive electrochemical sensor for paracetamol detection based on a layer-by-layer self-assembled poly(diallyl dimethylammonium chloride)/beta-cyclodextrin (PDDA/beta-CD) composite film. The optimized 5-bilayer PDDA/beta-CD modified glassy carbon electrode exhibited enhanced electron transfer kinetics and analyte preconcentration. Scanning electron microscopy revealed a porous, three-dimensional network structure, while X-ray photoelectron spectroscopy confirmed the successful incorporation of both PDDA and beta-CD components. Electrochemical impedance spectroscopy showed a minimum charge transfer resistance of 119 Omega for the 1-bilayer modified electrode. The sensor showed two distinct linear response intervals (0.01-50 mu M and 50-500 mu M) and was able to detect concentrations as low as 0.03 mu M. The investigation into pH dependence suggested that paracetamol oxidation follows a two-electron, two-proton mechanism, with the best results observed at pH 7.0. The modified electrode showed excellent selectivity, maintaining its response in the presence of common interferents at 10-fold excess concentrations. The sensor showed consistent results (relative standard deviation (RSD) = 3.2 %, n = 5) and remained stable over time, maintaining 92 % of its original performance after a month. Practical applicability was demonstrated through accurate paracetamol determination in pharmaceutical formulations (recoveries 98.6-101.2 %) and spiked urine samples (recoveries 97.8-102.5 %). The proposed PDDA/beta-CD composite sensor offers a simple, cost-effective, and environmentally friendly platform for paracetamol analysis in pharmaceutical and practical applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Layer-by-layer self-assembled polyelectrolyte membranes for solvent dehydration by pervaporation
    Zhu, Zhaoqi
    Feng, Xianshe
    Penlidis, Alexander
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2007, 27 (04): : 612 - 619
  • [22] Fabrication of Layer-By-Layer Self-Assembled Drug Delivery Platform for Prednisolone
    Patil, Ganesh B.
    Ramani, Ketan P.
    Pandey, Abhijeet P.
    More, Mahesh P.
    Patil, Pravin O.
    Deshmukh, Prashant K.
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2013, 52 (15) : 1637 - 1644
  • [23] PM IRRAS spectroelectrochemistry of layer-by-layer self-assembled polyelectrolyte multilayers
    Tagliazucchi, Mario
    Mendez De Leo, Lucila P.
    Cadranel, Alejandro
    Baraldo, Luis M.
    Volker, Edgar
    Bonazzola, Cecilia
    Calvo, Ernesto J.
    Zamlynny, Vlad
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 649 (1-2) : 110 - 118
  • [24] FLEXIBLE LAYER-BY-LAYER SELF-ASSEMBLED GRAPHENE BASED GLUCOSE BIOSENSORS
    Zhang, Bo
    Cui, Tony Zhengyu
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 11, 2012, : 757 - 760
  • [25] Perspectives and challenges for self-assembled layer-by-layer biosensor and biomaterial architectures
    Brett, Christopher M. A.
    CURRENT OPINION IN ELECTROCHEMISTRY, 2018, 12 : 21 - 26
  • [26] Biocompatibility of layer-by-layer self-assembled nanofilm on silicone rubber for neurons
    Ai, H
    Meng, HD
    Ichinose, I
    Jones, SA
    Mills, DK
    Lvov, YM
    Qiao, XX
    JOURNAL OF NEUROSCIENCE METHODS, 2003, 128 (1-2) : 1 - 8
  • [27] Layer-by-layer self-assembled multilayers of redox polyelectrolytes and gold nanoparticles
    Ferreyra, N
    Coche-Guérente, L
    Fatisson, J
    Teijelo, ML
    Labbé, P
    CHEMICAL COMMUNICATIONS, 2003, (16) : 2056 - 2057
  • [28] Layer-by-layer self-assembled conductive thin films for MEMS applications
    Bush, B
    Xu, GH
    Carraro, C
    Maboudian, R
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 126 (01) : 194 - 200
  • [29] Layer-by-layer self-assembled emerging systems for nanosized drug delivery
    Cini, Nejla
    Calisir, Ferah
    NANOMEDICINE, 2022, 17 (25) : 1961 - 1980
  • [30] Novel layer-by-layer self-assembled peptide nanocarriers for siRNA delivery
    Bozdogan, Betul
    Akbal, Oznur
    Celik, Ekin
    Turk, Mustafa
    Denkbas, Emir Baki
    RSC ADVANCES, 2017, 7 (75) : 47592 - 47601