Vector fitting-based full-bandwidth crosstalk suppression in triaxial optically pumped magnetometers

被引:0
|
作者
Liu, Ziao [1 ,2 ]
Li, Jianli [1 ,2 ]
Li, Xiaoyu [1 ,2 ]
Sheng, Jianwei [1 ,2 ]
Wang, Zhongyu [1 ,2 ]
Gao, Shushan [1 ,2 ]
Lu, Jixi [1 ,2 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Hefei Natl Lab, Hefei 230088, Peoples R China
基金
中国国家自然科学基金;
关键词
Crosstalk suppression; triaxial OPM; Vector fitting algorithm; MEG; MAGNETOENCEPHALOGRAPHY; SYSTEM;
D O I
10.1016/j.measurement.2025.117286
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Optically pumped magnetometers (OPMs) in magnetoencephalography (MEG) provide ultrahigh sensitivity and spatial resolution, making them a powerful new generation of MEG sensors. Recent studies suggest that triaxial OPMs, which can characterize the complete field vector and increase the amount of signal, represent a promising advancement for MEG applications. However, triaxial OPMs face an unavoidable inter-axis crosstalk issue, which limits the advantages of triaxial OPMs in MEG applications. This study modeled and comprehensively analyzed the inter-axis crosstalk, revealing that inter-axis crosstalk exhibits distinct frequency characteristics, which have not been considered in previous research. Due to the wide frequency range of human brain activity signals, the frequency characteristics of inter-axis crosstalk make it difficult to suppress effectively in practical applications. To address this problem, we proposed a vector fitting-based full-bandwidth crosstalk suppression method in triaxial OPMs. The vector fitting algorithm was employed to identify the transfer function model of the inter-axis crosstalk and derive a frequency-dependent correction matrix to suppress the inter-axis crosstalk in full bandwidth. The inter-axis crosstalk of the triaxial OPM was suppressed to less than 0.5 % within the frequency range of DC to 600 Hz. Our study presents a highly effective inter-axis crosstalk suppression method, which successfully addresses the application challenges of MEG using triaxial OPM.
引用
收藏
页数:9
相关论文
共 3 条
  • [1] In situ calibration of triaxial coils of a vector optically pumped magnetometers based on a particle swarm optimization algorithm
    Li, Siran
    Ma, Danyue
    Lu, Jixi
    Xing, Bozheng
    Wang, Kun
    Gao, Yanan
    Han, Bangcheng
    MEASUREMENT, 2022, 202
  • [2] Suppression of modulation-magnetic-fields crosstalk for single-beam optically-pumped magnetometers
    Suo, Yuchen
    Song, Xinda
    Jiang, Liwei
    Jia, Le
    Long, Tengyue
    Wu, Zhendong
    MEASUREMENT, 2023, 217
  • [3] Response of Lock-In Detection-Based Optically Pumped Magnetometers to High Bandwidth Magnetic Signals
    Yalaz, Mevluet
    Elzenheimer, Eric
    Wolframm, Henrik
    Knappe-Grueneberg, Silvia
    Hoeft, Michael
    Deuschl, Guenther
    Helmers, Ann-Kristin
    Sander, Tilmann
    IEEE SENSORS LETTERS, 2024, 8 (08)