Accelerometer-based estimation of respiratory rate using principal component analysis and autocorrelation

被引:0
|
作者
Hostrup, Mads C. F. [1 ]
Nielsen, Anne Sofie [1 ]
Sorensen, Freja E. [1 ]
Kragballe, Jesper O. [1 ]
Ostergaard, Morten U. [1 ]
Korsgaard, Emil [2 ]
Schmidt, Samuel E. [2 ]
Karbing, Dan S. [3 ]
机构
[1] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
[2] Aalborg Univ, Dept Hlth Sci & Technol, CardioTech Grp, Aalborg, Denmark
[3] Aalborg Univ, Dept Hlth Sci & Technol, Resp & Crit Care Grp, Aalborg, Denmark
关键词
respiratory rate; accelerometer; respiratory measurement; principal component analysis; autocorrelation; BREATHING PATTERNS;
D O I
10.1088/1361-6579/adbe23
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Respiratory rate (RR) is an important vital sign but is often neglected. Multiple technologies exist for RR monitoring but are either expensive or impractical. Tri-axial accelerometry represents a minimally intrusive solution for continuous RR monitoring, however, the method has not been validated in a wide RR range. Therefore, the aim of this study was to investigate the agreement between RR estimation from a tri-axial accelerometer and a reference method in a wide RR range. Approach. Twenty-five healthy participants were recruited. For accelerometer RR estimation, the accelerometer was placed on the abdomen for optimal breathing movement detection. The acquired accelerometry data were processed using a lowpass filter, principal component analysis (PCA), and autocorrelation. The subjects were instructed to breathe at slow, normal, and fast paces in segments of 60 s. A flow meter was used as reference. Furthermore, the PCA-autocorrelation method was compared with a similar single axis method. Main results. The PCA-autocorrelation method resulted in a bias of 0.0 breaths per minute (bpm) and limits of agreement (LOA) = [-1.9; 1.9 bpm] compared to the reference. Overall, 99% of the RRs estimated by the PCA-autocorrelation method were within +/- 2 bpm of the reference. A Pearson correlation indicated a very strong correlation with r = 0.99 ( p<0.001). The single axis method resulted in a bias of 3.7 bpm, LOA = [-14.9; 22.3 bpm], and r = 0.44 ( p<0.001). Significance. The results indicate a strong agreement between the PCA-autocorrelation method and the reference. Furthermore, the PCA-autocorrelation method outperformed the single axis method.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Accelerometer-based Human Fall Detection Using Fuzzy Entropy
    Howedi, Aadel
    Lotfi, Ahmad
    Pourabdollah, Amir
    2020 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE), 2020,
  • [32] Spatial Autocorrelation of Global Stock Exchanges Using Functional Areal Spatial Principal Component Analysis
    Khoo, Tzung Hsuen
    Pathmanathan, Dharini
    Dabo-Niang, Sophie
    MATHEMATICS, 2023, 11 (03)
  • [33] Posture transition analysis with barometers: contribution to accelerometer-based algorithms
    Rodriguez-Martin, Daniel
    Sama, Albert
    Perez-Lopez, Carlos
    Catala, Andreu
    Cabestany, Joan
    NEURAL COMPUTING & APPLICATIONS, 2020, 32 (02): : 335 - 349
  • [34] Accelerometer-Based Gait Recognition Using PCA & LDA Algorithms
    Mao, Chenfei
    Li, Ye
    Sun, Fangmin
    2018 IEEE 23RD INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2018,
  • [35] Accelerometer-Based Gait Analysis for Patients with Parkinson's Disease
    Tang, S-T.
    Tai, C-H.
    Lai, Y-H.
    Lee, T-C.
    MOVEMENT DISORDERS, 2019, 34 : S928 - S929
  • [36] Posture transition analysis with barometers: contribution to accelerometer-based algorithms
    Daniel Rodríguez-Martín
    Albert Samà
    Carlos Pérez-López
    Andreu Català
    Joan Cabestany
    Neural Computing and Applications, 2020, 32 : 335 - 349
  • [37] Accuracy of tibial component placement in unicompartmental knee arthroplasty performed using an accelerometer-based portable navigation system
    Yoshio Matsui
    Shinichi Fukuoka
    Sho Masuda
    Masanori Matsuura
    Toshiaki Masada
    Kenji Fukunaga
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 3733 - 3739
  • [38] Accuracy of tibial component placement in unicompartmental knee arthroplasty performed using an accelerometer-based portable navigation system
    Matsui, Yoshio
    Fukuoka, Shinichi
    Masuda, Sho
    Matsuura, Masanori
    Masada, Toshiaki
    Fukunaga, Kenji
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (12) : 3733 - 3739
  • [39] Accelerometer-Based Timing Analysis for Parkinson's Disease Classification
    Onay, Fatih
    Karacali, Bilge
    2023 31ST SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU, 2023,
  • [40] Accelerometer-based Tilt Estimation of a Rigid Body with only Rotational Degrees of Freedom
    Trimpe, Sebastian
    D'Andrea, Raffaello
    2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, : 2630 - 2636