Commissioning a clinical proton pencil beam scanning beamline for pre-clinical ultra-high dose rate irradiations on a cyclotron-based system

被引:0
|
作者
Saini, Jatinder [1 ,2 ]
Erickson, Danielle P. Johnson [1 ]
Stappen, Francois Vander [3 ]
Ruth, Matt [1 ,2 ]
Cui, Sunan [1 ,2 ]
Gorman, Vanessa [3 ]
Rossomme, Severine [3 ]
Cao, Ning [1 ,2 ]
Ford, Eric C. [1 ,2 ]
Meyer, Juergen [1 ,2 ]
Bloch, Charles [1 ,2 ]
Wong, Tony [1 ,2 ]
Grassberger, Clemens [1 ]
Rengan, Ramesh [1 ,2 ]
Zeng, Jing [1 ,2 ]
Schwarz, Marco [1 ,2 ]
机构
[1] Univ Washington, Sch Med, Dept Radiat Oncol, Seattle, WA 98195 USA
[2] Fred Hutchinson Canc Ctr, Radiat Oncol, Seattle, WA 98109 USA
[3] Proton Therapy Res & Dev, Ion Beam Applicat, Louvain La Neuve, Belgium
来源
FRONTIERS IN ONCOLOGY | 2024年 / 14卷
关键词
ultra-high dose rate; FLASH; protons; pencil beam scanning; pre-clinical;
D O I
10.3389/fonc.2024.1460288
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background This manuscript describes modifications to a pencil beam scanning (PBS) proton gantry that enables ultra-high dose rates (UHDR) irradiation, including treatment planning and validation. Methods Beamline modifications consisted of opening the energy slits and setting the degrader to pass-through mode to maximize the dose rate. A range shifter was inserted upstream from the isocenter to enlarge the spot size and make it rotationally symmetric. We measured the beamline transport efficiency and investigated the variation in output due to the recombination of charge in the dose monitoring chamber. The output calibration was performed through a parallel plate chamber (PPC05), and an intercomparison was performed for various detectors. The pre-clinical field for mice irradiation consisted of different dose levels to deliver uniform doses in transmission mode. The field dose rates were determined through log files while scripting in TPS was used to estimate PBS dose rates. The survival experiments consisted of irradiating the full pelvis of the mice at UHDR and conventional dose rates. Results The spot size was constant with beam current and had a sigma of 8.5 mm at the isocenter. The beam output increased by 35% at 720 nA compared to 5.6 nA, primarily due to recombination in the dose-monitoring ion chambers. The Faraday Cup and PPC05 agreed within 2%, while other detectors were within 3% of FC for dose rates <60 Gy/s. The pre-clinical fields' PBS dose rate is above 45 Gy/sec for all voxels within the target volume. The average and PBS dose rates decrease as field size increases and approaches 40 Gy/s for a field size of 7x7 cm2. All UHDR arms showed better survival than the corresponding conventional dose rate arms. Conclusions We successfully modified a clinical system to perform UHDR pre-clinical experiments. As part of our pre-clinical experiments, we observed the FLASH effect concerning mice survival.
引用
收藏
页数:13
相关论文
共 25 条
  • [1] Commissioning of a clinical pencil beam scanning proton therapy unit for ultra-high dose rates (FLASH)
    Nesteruk, Konrad P.
    Togno, Michele
    Grossmann, Martin
    Lomax, Anthony J.
    Weber, Damien C.
    Schippers, Jacobus M.
    Safai, Sairos
    Meer, David
    Psoroulas, Serena
    MEDICAL PHYSICS, 2021, 48 (07) : 4017 - 4026
  • [2] Multi-institutional consensus on machine QA for isochronous cyclotron-based systems delivering ultra-high dose rate (FLASH) pencil beam scanning proton therapy in transmission mode
    Spruijt, Kees
    Mossahebi, Sina
    Lin, Haibo
    Lee, Eunsin
    Kraus, James
    Dhabaan, Anees
    Poulsen, Per
    Lowe, Matthew
    Ayan, Ahmet
    Spiessens, Sylvie
    Godart, Jeremy
    Hoogeman, Mischa
    MEDICAL PHYSICS, 2024, 51 (02) : 786 - 798
  • [3] Ultra-high dose rate dosimetry for pre-clinical experiments with mm-small proton fields
    Togno, M.
    Nesteruk, K. P.
    Schafer, R.
    Psoroulas, S.
    Meer, D.
    Grossmann, M.
    Christensen, J. B.
    Yukihara, E. G.
    Lomax, A. J.
    Weber, D. C.
    Safai, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 101 - 111
  • [4] Faraday cup for commissioning and quality assurance for proton pencil beam scanning beams at conventional and ultra-high dose rates
    Winterhalter, C.
    Togno, M.
    Nesteruk, K. P.
    Emert, F.
    Psoroulas, S.
    Vidal, M.
    Meer, D.
    Weber, D. C.
    Lomax, A.
    Safai, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [5] Improved Tumor Control Through T-cell Infiltration Modulated by Ultra-High Dose Rate Proton FLASH Using a Clinical Pencil Beam Scanning Proton System
    Rama, N.
    Saha, T.
    Shukla, S.
    Goda, C.
    Milewski, D.
    Mascia, A. E.
    Vatner, R. E.
    Sengupta, D.
    Katsis, A.
    Abel, E.
    Girdhani, S.
    Miyazaki, M.
    Rodriguez, A.
    Ku, A.
    Dua, R.
    Parry, R.
    Kalin, T. V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S164 - S165
  • [6] Feasibility of Synchrotron-Based Ultra-High Dose Rate (UHDR) Proton Irradiation with Pencil Beam Scanning for FLASH Research
    Yin, Lingshu
    Masumi, Umezawa
    Ota, Kan
    Sforza, Daniel M.
    Miles, Devin
    Rezaee, Mohammad
    Wong, John W.
    Jia, Xun
    Li, Heng
    CANCERS, 2024, 16 (01)
  • [7] Voxel-wise dose rate calculation in clinical pencil beam scanning proton therapy
    Daartz, Juliane
    Madden, Thomas M.
    Lalonde, Arthur
    Cascio, Ethan
    Verburg, Joost
    Shih, Helen
    MacDonald, Shannon
    Hachadorian, Rachael
    Schuemann, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (06):
  • [8] Technical Note: Defining cyclotron-based clinical scanning proton machines in a FLUKA Monte Carlo system
    Fiorini, Francesca
    Schreuder, Niek
    Van den Heuvel, Frank
    MEDICAL PHYSICS, 2018, 45 (02) : 963 - 970
  • [9] Ultra-High Dose Rate (FLASH) Proton Beam Scanning in Clinical Gantry: Evaluation of Biological Benefit in Radiation Induced Skin Fibrosis and Muscle Atrophy
    Sertorio, M.
    Vairamani, K.
    McCauley, S.
    Cunningham, S.
    Speth, J.
    Perentesis, J.
    Mascia, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E295 - E295
  • [10] Characterization of a Modified Clinical Linear Accelerator for Ultra-High Dose Rate Beam Delivery
    Deut, Umberto
    Camperi, Aurora
    Cavicchi, Cristiano
    Cirio, Roberto
    Data, Emanuele Maria
    Durisi, Elisabetta Alessandra
    Ferrero, Veronica
    Ferro, Arianna
    Giordanengo, Simona
    Villarreal, Oscar Marti
    Mas Milian, Felix
    Medina, Elisabetta
    Olivares, Diango M. Montalvan
    Mostardi, Franco
    Monti, Valeria
    Sacchi, Roberto
    Salmeri, Edoardo
    Vignati, Anna
    APPLIED SCIENCES-BASEL, 2024, 14 (17):