Experimental investigation of the performance of a PVT heat pump soil cross-seasonal energy storage system across various operation modes

被引:0
|
作者
Jiang, Duhui [1 ]
Zhang, Jili [1 ]
Lou, Lanting [1 ]
Lou, Lanlan [2 ]
Zhu, Kai [2 ]
Dai, Jinshun [3 ]
机构
[1] Dalian Univ Technol, Fac Infrastructure Engn, Dalian 116024, Peoples R China
[2] Dalian Qunzhi Swarm Co Ltd, Dalian 116024, Peoples R China
[3] Xiajin Urban & Rural Dev Grp Co Ltd, Dezhou 253000, Peoples R China
关键词
PVT heat pump; Soil cross-seasonal energy storage; Operation mode; COPs; Experimental investigation; SOLAR; OPTIMIZATION; COLLECTORS;
D O I
10.1016/j.energy.2025.135656
中图分类号
O414.1 [热力学];
学科分类号
摘要
To improve the energy efficiency of a photovoltaic thermal (PVT) heat pump system designed for soil-based cross-seasonal energy storage, this study empirically evaluates its performance across multiple operational modes. The system operates in eight distinct modes: soil source heat pump (SSHP) heating, a combination of PVT heating and SSHP heating (PVTSSHP heating), PVT heat pump (PVTHP) heating, standalone PVT heating, soil cooling, SSHP cooling, PVTSSHP cooling, and PVT heating with soil energy storage. Experimental analyses are performed to explore system behavior under representative annual conditions. Under these typical conditions, the system COPs for SSHP heating, PVTSSHP heating, PVTHP heating, PVT heating, soil cooling, SSHP cooling, and PVTSSHP cooling are determined as 4.1, 3.2, 4.2, 10.5, 10.6, 3.3, and 2.7, respectively. The heat pump COP for SSHP heating, PVTSSHP heating, PVTHP heating, SSHP cooling, and PVTSSHP cooling are recorded as 5.9, 6.8, 7.9, 5.0, and 4.9, respectively. Additionally, the thermal efficiency of the PVT array under different operational modes is measured at 27.0 % for PVTSSHP heating, 20.0 % for PVTHP heating, 14.2 % for PVT heating, 48.9 % for PVTSSHP cooling, and 32.9 % for PVT heating soil mode. The electrical efficiency of the PVT array is reported for all modes as 16.9 %, 16.5 %, 16.4 %, 16.0 %, 14.7 %, 15.5 %, 16.0 %, and 16.4 %.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Performance research on the system of heat pump water heater with energy storage
    Li, Jianxin
    Wang, Yongchuan
    Chen, Guangming
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2008, 29 (10): : 1230 - 1234
  • [32] ANALYSIS OF THE OPERATION MODES OF A SOLAR AND AIR SOURCE HEAT PUMP INTEGRATED SYSTEM WITH TRIPLE-SLEEVE ENERGY STORAGE EXCHANGERS
    Yang, Lingyan
    Yao, Yang
    Jiang, Yiqiang
    Ma, Zuiliang
    Zhou, Quan
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1934 - 1941
  • [33] Theoretical and experimental investigation of the performance of adsorption heat storage system
    Helaly, Hesham O.
    Awad, Mohamed M.
    El-Sharkawy, Ibrahim I.
    Hamed, Ahmed M.
    APPLIED THERMAL ENGINEERING, 2019, 147 : 10 - 28
  • [34] Seasonal Performance Investigation for Residential Heat Pump System with Different Outdoor Heat Exchanger Designs
    Ishaque, Shehryar
    Kim, Man-Hoe
    ENERGIES, 2019, 12 (24)
  • [35] Experimental and computational investigation of a latent heat energy storage system with a staggered heat exchanger for various phase change materials
    Koukou, Maria K.
    Vrachopoulos, Michalis Gr
    Tachos, Nikolaos S.
    Dogkas, George
    Lymperis, Kostas
    Stathopoulos, Vassilis
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 7 : 87 - 98
  • [36] Energy pile-based ground source heat pump system with seasonal solar energy storage
    Ma, Qijie
    Fan, Jianhua
    Liu, Hantao
    RENEWABLE ENERGY, 2023, 206 : 1132 - 1146
  • [37] Experimental investigation on the dynamic thermal performance of the parallel solar-assisted air-source heat pump latent heat thermal energy storage system
    Jin, Xin
    Zhang, Huihui
    Huang, Gongsheng
    Lai, Alvin CK.
    RENEWABLE ENERGY, 2021, 180 : 637 - 657
  • [38] Performance of a demonstration solar PVT assisted heat pump system with cold buffer storage and domestic hot water storage tanks
    Dannemand, Mark
    Perers, Bengt
    Furbo, Simon
    ENERGY AND BUILDINGS, 2019, 188 : 46 - 57
  • [39] Simulation method for a pit seasonal thermal energy storage system with a heat pump in a district heating system
    Sorknaes, Peter
    ENERGY, 2018, 152 : 533 - 538
  • [40] EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF A HEAT PIPE UNDER VARIOUS MODES OF CONDENSER COOLING
    Arulselvan, A.
    Pandiyarajan, V.
    Velraj, R.
    HEAT TRANSFER RESEARCH, 2017, 48 (13) : 1151 - 1164