Ultrasound Derived Inferior Vena Cava Diameter and Collapsibility Index to Predict Central Venous Pressure Prior and After A Fluid Challenge in Spontaneous Breathing Preoperative Patients

被引:0
|
作者
Talreja, Neha Gopal [1 ]
Shetty, Vijay [1 ]
机构
[1] Fortis Hosp Mulund Goregaon Link Rd, Mumbai 400078, Maharashtra, India
关键词
Central venous pressure (CVP); collapsibility index (CI); inferior vena cava (IVC) diameters; passive leg raising (PLR); RIGHT ATRIAL PRESSURE; NONINVASIVE ESTIMATION; EUROPEAN-ASSOCIATION; AMERICAN-SOCIETY; RIGHT-HEART; RESPONSIVENESS; VOLUME; ECHOCARDIOGRAPHY; ULTRASONOGRAPHY; GUIDELINES;
D O I
10.21608/ASJA.2024.250976.1021
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Central venous pressure (CVP) is indicator of preload and used to determine intravascular volume status. An invasive method such as central venous catheter placement is required in order to measure CVP. However, it is associated with many complications. Instead, sonographic measurement of inferior vena cava (IVC) represents effective and noninvasive method of estimating CVP and recommendations are provided by the American Society of Echocardiography (ASE). There are various methods to calculate and estimate CVP using ultrasound. One of the ultrasonographic (US) technique for obtaining the JVP from a high-resolution B-mode sonogram sequences (US-JVP), recording the changes in IJV-CSA (cross section area) over the cardiac cycle (CC) has been proposed which appears to have potential as an approach for estimating CVP. Patients and Methods: It is a prospective double blinded observational study conducted at tertiary hospital among 40 consenting patients. Results: We found that 27 patients (67.5%) had correct prediction of CVP by USG with measured CVP after transducing central venous catheter at baseline (supine position). Similarly, 19 patients (47.5%) had correct prediction of CVP with measured CVP after passive leg raising. We found that 14 patients (35%) had 10% rise in mean arterial pressure on passive leg raising. We denoted these patients as Responders. We found that both responders and non-responders had poor correlation with CVP prediction. Also IVC diameters and collapsibility index did not predict the fluid responsiveness of the patients. Spearman correlation coefficient was used to study correlation between two quantitative variables. In our study, we found a strong positive correlation between predicted CVP (determined by USG parameters) and measured CVP (determined by transducing central venous catheter on monitor) at baseline (supine position) and after passive leg raising. Multivariate regression analysis was done to find the significant predictor of CVP which was found to be IVC maximum diameter (p value 0.01) determined by USG. Conclusion: Bedside USG in preoperative patients can be used as a simple and reliable method to calculate IVC diameters and collapsibility index to predict CVP. It requires minimal training and correlates well with real time transduced CVP. In our study of 40 patients we aimed to study the ability of the ultrasound guided measurements of the Inferior Vena Cava in predicting the Central Venous Pressure (CVP). A strong positive correlation was found between the predicted CVP and measured/transduced CVP in supine position 8 (baseline) and after passive leg raising. On multivariate regression analysis, the IVC maximum diameter determined by USG was found to be the significant predictor of CVP. No significant correlation was noted between IVC parameters, Collapsibility index and CVP values to predict fluid responsive nature of the patients.
引用
收藏
页数:10
相关论文
共 42 条
  • [31] COMPARING ULTRASOUND-BASED MEASURES OF THE INTERNAL JUGULAR VEIN AND THE INFERIOR VENA CAVA AS ESTIMATORS OF CENTRAL VENOUS PRESSURE IN PATIENTS WITH CIRRHOSIS
    Aguirre-Villarreal, David
    Leal-Villarreal, Mario A.
    Vidal-Mayo, Jose D.
    Garcia-Juarez, Ignacio
    GASTROENTEROLOGY, 2023, 164 (06) : S1321 - S1321
  • [32] Does ultrasonographic measurement of the inferior vena cava diameter correlate with central venous pressure in the assessment of intravascular volume in patients undergoing gastrointestinal surgery?
    Zhang, Xiaobao
    Luan, Hengfei
    Zhu, Pin
    Feng, Jiying
    Cui, Jizheng
    Zhao, Zhibin
    JOURNAL OF SURGICAL RESEARCH, 2014, 191 (02) : 339 - 343
  • [33] Comparative Analysis of the Collapsibility Index and Distensibility Index of the Inferior Vena Cava Through Echocardiography with Pulse Pressure Variation That Predicts Fluid Responsiveness in Surgical Patients: An Observational Controlled Trial
    Pereira, Renan Muralho
    Leite Campelo da Silva, Alvaro Jose
    Faller, Julio
    Gomes, Brenno Cardoso
    Silva Jr, Joao Manoel
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (08) : 2162 - 2168
  • [34] Central venous pressure, global end-diastolic index, and the inferior vena cava collapsibility/distensibility indices to estimate intravascular volume status in critically ill children: A pilot study
    Aslan, Nagehan
    Yildizdas, Dincer
    Horoz, Ozden Ozgur
    Coban, Yasemin
    Arslan, Didar
    Sertdemir, Yasar
    AUSTRALIAN CRITICAL CARE, 2021, 34 (03) : 241 - 245
  • [35] Prospective evaluation of intravascular volume status in critically ill patients: Does inferior vena cava collapsibility correlate with central venous pressure? (vol 74, pg 956, 2014)
    Stawicki, P. A.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 76 (05): : 1337 - 1337
  • [36] Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
    Qian Ma
    Jingjing Ji
    Xueduo Shi
    Ziyun Lu
    Lu Xu
    Jing Hao
    Wei Zhu
    Bingbing Li
    BMC Anesthesiology, 22
  • [37] Comparison of superior and inferior vena cava diameter variation measured with transthoracic echocardiography to predict fluid responsiveness in mechanically ventilated patients after abdominal surgery
    Ma, Qian
    Ji, Jingjing
    Shi, Xueduo
    Lu, Ziyun
    Xu, Lu
    Hao, Jing
    Zhu, Wei
    Li, Bingbing
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [38] Inferior Vena Cava Diameter (IVCD) Measured with Transesophageal Echocardiography (TEE) Can Be Used to Derive the Central Venous Pressure (CVP) in Anesthetized Mechanically Ventilated Patients
    Arthur, Mary E.
    Landolfo, Carolyn
    Wade, Marlene
    Castresana, Manuel R.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (02): : 140 - 149
  • [39] SHoC-IVC: Does assessment of the inferior vena cava by point-of-care ultrasound independently predict fluid status in spontaneously breathing patients with undifferentiated hypotension?
    Dunfield, Robert
    Ross, Peter
    Dutton, Daniel
    Chandra, Kavish
    Lewis, David
    Scheuermeyer, Frank
    Fraser, Jacqueline
    Boreskie, Patrick
    Pham, Chau
    Ali, Sultan
    Lamprecht, Hein
    Stander, Melanie
    Keyes, Cameron
    Henneberry, Ryan
    Atkinson, Paul
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2023, 25 (11) : 902 - 908
  • [40] SHoC-IVC: Does assessment of the inferior vena cava by point-of-care ultrasound independently predict fluid status in spontaneously breathing patients with undifferentiated hypotension?
    Robert Dunfield
    Peter Ross
    Daniel Dutton
    Kavish Chandra
    David Lewis
    Frank Scheuermeyer
    Jacqueline Fraser
    Patrick Boreskie
    Chau Pham
    Sultan Ali
    Hein Lamprecht
    Melanie Stander
    Cameron Keyes
    Ryan Henneberry
    Paul Atkinson
    Canadian Journal of Emergency Medicine, 2023, 25 : 902 - 908