Switching of elevated electromagnetic and electrostatic induced currents in multi-circuit, multi-voltage HVAC transmission lines

被引:0
|
作者
Lathouwers, Andre [1 ]
van der Born, Dennis [1 ]
机构
[1] Delft Univ Technol, High Voltage Technol, Delft, Netherlands
关键词
electrostatic and electromagnetic induced current switching; combined overhead lines; energy transition; transposition;
D O I
10.1109/ICHVE61955.2024.10676259
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a future-proof switching procedure for the switching of increasing electrostatic (e.s.) and electromagnetic (e.m.) induced currents with a line side earthing switch. The induced currents are becoming much higher than stated by IEC-standards due to increasing line current and the use of combined (un-transposed) overhead lines. Notorious are overhead lines with different voltage levels combined at single pylons. This adapted switching procedure becomes even more important due to the increasing amount of Gas Insulated Switchgear (GIS) being introduced in the grid.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Non-contact fault location and identification method for same-tower multi-circuit transmission lines
    Yin, Tao
    Li, Jian
    Cai, Dongsheng
    Huang, Qi
    Hu, Weihao
    ENERGY REPORTS, 2021, 7 : 147 - 158
  • [42] Research on Safety Protection for Live Working on 1000kV AC Transmission Line with AC and DC Multi-circuit Transmission Lines
    Xie, Yan
    Li, Mu
    Xiang, Tao
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [43] Research on Safety Protection for Live Working on ±500kV DC Transmission Line with AC and DC Multi-circuit Transmission Lines
    Xie, Yan
    Li, Mu
    Zheng, Changzheng
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS, MECHATRONICS AND CIVIL ENGINEERING (ICAMMCE 2017), 2017, 121 : 53 - 56
  • [44] Influencing factors of lightning outage in multi-circuit transmission lines on same tower in Guangdong power grid and fault analysis
    Peng, Xiangyang
    Zhan, Qinghua
    Zhou, Huamin
    Dianwang Jishu/Power System Technology, 2012, 36 (03): : 81 - 87
  • [45] Research on safety protection for live working on ±800kV DC transmission line with AC and DC multi-circuit transmission lines
    Xie, Yan
    Xiang, Tao
    Li, Mu
    3RD INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2017, 61
  • [46] EMC Prediction Method of High Voltage Multi-Circuit Transmission on the Same Tower Based on Improved Least Squares Method
    Xue, Hua
    Li, Hai Xia
    Hu, Xu
    2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 533 - 534
  • [47] Mechanism and solution of zero-sequence directional protection maloperation caused by broken line faults in multi-circuit transmission lines on the same tower
    Dai, Feiyang
    Wang, Xingguo
    Yang, Guosheng
    2018 INTERNATIONAL SEMINAR ON COMPUTER SCIENCE AND ENGINEERING TECHNOLOGY (SCSET 2018), 2019, 1176
  • [48] Substation Information Based Method for Preventing Mal-operation of Zero-sequence Directional Protection on Multi-circuit Transmission Lines on the Same Tower
    Dai F.
    Wang X.
    Yang G.
    Zhou Z.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (13): : 131 - 138
  • [49] A novel multi-slice electromagnetic field-circuit coupling method for transient computation of long-distance gas-insulated transmission lines
    Cheng, Shucan
    Zhao, Yanpu
    Xie, Kejia
    Hu, Bin
    HIGH VOLTAGE, 2024, 9 (04) : 826 - 838
  • [50] Research on the Effect of Induced Voltages in Transient Stability for Multi Circuit Modeling on 500 kV EHV Parallel Transmission Lines Using a Modified Genetic Algorithm
    Jaipradidtham, Chamni
    Naksuriyavong, Artiwat
    2014 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2014,