Utility of Central Venous Oxygen Saturation Gradient in Predicting Mortality in Dialysis with Catheter Access

被引:0
|
作者
Wu, Hung-Chieh [1 ,2 ]
Wang, Wei-lie [3 ]
机构
[1] Taoyuan Gen Hosp, Minist Hlth & Welf, Dept Internal Med, Div Nephrol, Taoyuan, Taiwan
[2] Ming Chuan Univ, Dept Biotechnol, Taipei, Taiwan
[3] Lo Sheng Sanat & Hosp, Dept Internal Med, Taoyuan, Taiwan
来源
MEDICAL SCIENCE MONITOR | 2025年 / 31卷
关键词
Dialysis; Mortality; Oxygen Saturation; Ultrafiltration; ABSOLUTE BLOOD-VOLUME; HEMODIALYSIS-PATIENTS; INTRADIALYTIC HYPOTENSION; FLUID OVERLOAD; ALL-CAUSE; INFLAMMATION;
D O I
10.12659/MSM.947298
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Central venous oxygen saturation (ScvO2), a biomarker that is well-correlated with arterial oxygen saturation, can predict mortality. Few studies have focused on blood volume, ScvO2, and mortality in patients on maintenance dialysis. This retrospective study used hospital record data of 144 dialysis patients with central venous catheter access (CVC) and aimed to evaluate the ScvO2 gradient, blood volume, and patient mortality. We examined the associations among absolute blood volume (ABV), mean ScvO2, intradialytic slope of ScvO2, and mortality in patients on dialysis. Material/Methods: Adult patients receiving dialysis via CVC from 2022 to 2024 were enrolled. ScvO2, ABV, and protocol-based ultrafiltration were monitored using Crit-Line IV (Fresenius Medical Care, Bad Homburg, Germany). Participants were assessed and followed until death or administrative censor. Multiple fractional polynomial (MFP) regression was used to determine best-fitting polynomial function between predictors and mortality. We also constructed proportional hazard model to compare trends of ScvO2 for mortality. Results: In a total of 144 eligible patients, the incidence of mortality was 14.5 per 1000 patient-months. The correlation between mean ScvO2 and mortality was weak (r=-0.05), whereas the association between ABV change and mean ScvO2 were a reverse U curve. The intradialytic slope of ScvO2 was independently associated with mortality (adjusted odds ratio [95% CI]=0.421 [0.226-0.783], P<0.05). Those with descending slope of ScvO2 had higher risk of mortality than those with an ascending slope (HR [95% CI]=3.98 [1.22-13.03], P<0.05). Conclusions: A negative trend of intradialytic ScvO2 was associated with mortality.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Femoral venous oxygen saturation and central venous oxygen saturation in critically ill patients
    Zhang, Xiaohong
    Wang, Jiandong
    Dong, Yun
    Chen, Youdai
    JOURNAL OF CRITICAL CARE, 2015, 30 (04) : 768 - 772
  • [12] Dialysis central venous catheter types and performance
    Gallieni, Maurizio
    Brenna, Irene
    Brunini, Francesca
    Mezzina, Nicoletta
    Pasho, Sabina
    Giordano, Antonino
    JOURNAL OF VASCULAR ACCESS, 2014, 15 : S140 - S146
  • [13] Initial central venous saturation of oxygen as predictive factor of mortality in patients with sepsis
    Penott-Gutierrez, Odalis
    Reyna-Villasmil, Eduardo
    MEDULA, 2013, 22 (01): : 15 - 20
  • [14] Influence of Central Venous Oxygen Saturation on In-hospital Mortality of Surgical Patients
    Silva Junior, Joao Manoel
    Ribas Rosa Oliveira, Amanda Maria
    de Morais, Sandra Zucchi
    de Araujo, Luciana Sales
    Victoria, Luiz Gustavo F.
    Marubayashi, Lauro Yoiti
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2010, 60 (06): : 593 - 602
  • [15] Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation
    El Masry, A.
    Mukhtar, A. M.
    El Sherbeny, A. M.
    Fathy, M.
    El-Meteini, M.
    ANAESTHESIA, 2009, 64 (04) : 378 - 382
  • [16] Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    Marjut Varpula
    Sari Karlsson
    Esko Ruokonen
    Ville Pettilä
    Intensive Care Medicine, 2006, 32 : 1336 - 1343
  • [17] Are central venous oxygen saturation and mixed venous oxygen saturation truly inter-changeable.
    Nascimento, Jeffrey
    Kaplan, Rana
    Rogers, Murray
    Mina, Bushra
    Mintz, Edward
    CRITICAL CARE MEDICINE, 2006, 34 (12) : A104 - A104
  • [18] Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    Varpula, Marjut
    Karlsson, Sari
    Ruokonen, Esko
    Pettila, Ville
    INTENSIVE CARE MEDICINE, 2006, 32 (09) : 1336 - 1343
  • [19] FEMORAL VENOUS OXYGEN SATURATION AS A SUBSTITUTE OF CENTRAL VENOUS OXYGEN SATURATION IN CRITICALLY ILL PATIENTS
    Marti, Y. N.
    Milena, L. B.
    de Azevedo, R. P.
    Machado, F. R.
    INTENSIVE CARE MEDICINE, 2013, 39 : S485 - S485
  • [20] ACCURACY AND CLINICAL UTILITY OF AN OXYGEN-SATURATION CATHETER
    KROUSKOP, RW
    CABATU, EE
    CHELLIAH, BP
    MCDONNELL, FE
    BROWN, EG
    CRITICAL CARE MEDICINE, 1983, 11 (09) : 744 - 749