共 23 条
Comprehensive analysis of particulate matter, gaseous pollutants, and microbiological contamination in a clothing store from an international chain in Europe
被引:0
|作者:
Furst, Leonardo
[1
]
Cipoli, Yago
[1
]
Galindo, Nuria
[2
]
Yubero, Eduardo
[2
]
Viegas, Carla
[3
,4
]
Gomes, Bianca
[3
,4
]
Cervantes, Renata
[3
,4
]
Nunes, Teresa
[1
]
Feliciano, Manuel
[5
,6
]
Alves, Celia
[1
]
机构:
[1] Univ Aveiro, Ctr Environm & Marine Studies CESAM, Dept Environm, P-3810193 Aveiro, Portugal
[2] Miguel Hernandez Univ, Dept Appl Phys, Elche, Spain
[3] Inst Politecn Lisboa, ESTeSL Escola Super Tecnol & Saude, H &TRC Hlth & Technol Res Ctr, P-1990096 Lisbon, Portugal
[4] Nova Univ Lisbon, NOVA Natl Sch Publ Hlth, Comprehens Hlth Res Ctr CHRC, Publ Hlth Res Ctr,REAL, P-1099085 Lisbon, Portugal
[5] Inst Politecn Braganca, CIMO, SusTEC, Campus Santa Apolonia, P-5300253 Braganca, Portugal
[6] Inst Politecn Braganca, Lab Associado Sustentabilidade & Tecnol Regioes Mo, Campus Santa Apolonia, P-5300253 Braganca, Portugal
关键词:
Clothing store;
Indoor air quality;
PM10;
VOCs;
Bioburden;
ALPHA-PINENE;
TRACE-METALS;
AIR-QUALITY;
INDOOR;
LIMONENE;
HEALTH;
PRODUCTS;
EXPOSURE;
FUNGI;
PM2.5;
D O I:
10.1016/j.envpol.2025.125836
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
In this study, indoor air quality was assessed in a store belonging to one of Portugal's largest commercial retail groups. A variety of methodologies was used, including gravimetric analysis for particulate matter (PM), optical monitors for real-time PM measurements, gas sensors and analysers for CO2 and other gaseous pollutants, diffusion tubes for VOCs, and passive deposition for microorganisms. The average PM10 concentration indoors was 16.5 +/- 3.87 mu g/m3, well below the exposure limits set by various international organisations. A significant portion of indoor PM10 - 69%- was originated from outdoor sources. Outdoor PM10 concentrations were substantially higher, averaging 29.4 +/- 14.6 mu g/m3. Metal concentrations were also higher outdoors than indoors, and the associated cancer risk and hazard quotient were not exceeded, indicating favourable air quality conditions within the store. Among VOCs, alpha-pinene and tetrachloroethylene were detected in notable concentrations. alpha-Pinene likely originated from cleaning products and fragrances, while tetrachloroethylene was attributed to emissions from a dry-cleaning establishment located in the same building, but did not exceed protection thresholds. Microbial analysis showed low concentrations of both fungi and bacteria. However, fungal species with clinical and toxigenic potential were found. The most common fungal species were Trichoderma sp. and Penicillium sp., depending on the culture media. Overall, the clothing store demonstrated good air quality. However, to further reduce the impact of outdoor pollutants on indoor air quality, enhancements to the ventilation system are recommended. These improvements can help create a healthier indoor environment by filtering and managing the intake of external contaminants more effectively.
引用
收藏
页数:10