Research on the Design of Nonuniform Field Coils With Ferromagnetic Coupling in Magnetically Shielded Cylinder for Magnetocardiogram

被引:0
|
作者
Wang, Weiqian [1 ,2 ,3 ]
Zhou, Xiangyang [1 ,2 ,3 ]
Zhao, Fengwen [4 ]
Xie, Xiaoxuan [1 ,2 ,3 ]
Lian, Yunyang [4 ]
Yin, Chuanming [1 ,2 ,3 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Inst Large Scale Sci Facil, Beijing 100191, Peoples R China
[3] Beihang Univ, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Natl Inst Extremely Weak Magnet Field Infrastruct, Hangzhou 310000, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Magnetic field measurement; Coils; Magnetic fields; Magnetic shielding; Magnetic noise; Magnetic resonance imaging; Remanence; Couplings; Interference; Analytical models; Coupling effect; magnetically shielded cylinder (MSC); magnetocardiogram (MCG); nonuniform field coils (NUFCs); target field method (TFM); SHIM;
D O I
10.1109/TIM.2024.3502873
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To reduce the influence of remanence and interference on magnetocardiogram (MCG) measurements, an approach to designing nonuniform field coils (NUFCs) considering ferromagnetic coupling effects is proposed. First, a magnetic field analytical model considering the coupling effects between the magnetically shielded cylinder (MSC) and coils is established based on the distribution of the magnetic vector potential combined with the image method (IM). Subsequently, using the target field method (TFM), the NUFCs are designed inversely according to the distribution of remanence and interference, by which the problem that existing uniform field coils (UFCs) are difficult to compensate for nonuniform magnetic fields is solved. Furthermore, to improve the performance of the NUFCs, the adaptive inertia weight particle swarm optimization (PSO) method is introduced for optimizing the regularization parameters. Finally, finite-element simulations and experiments are carried out to verify the proposed method. The results from the experiments demonstrate that the remanence within the measurement area is reduced from 60 to below 10 nT by designed NUFCs, while magnetic field interference is effectively suppressed from 37 to 11 pT. These results prove the effectiveness of the designed NUFCs in enhancing the magnetic field performance of MCG devices.
引用
收藏
页数:10
相关论文
共 39 条
  • [11] Realization of a Multishell Magnetically Shielded Cylinder for SERF Magnetometer Via Hybrid Design Method
    Yang, Kang
    Zhang, Yongle
    Zhang, Qiannian
    Zhao, Ahui
    Zhang, Hongwei
    Huang, Dengchao
    Kong, Xiangyan
    IEEE SENSORS JOURNAL, 2023, 23 (21) : 25836 - 25843
  • [12] Bespoke magnetic field design for a magnetically shielded cold atom interferometer
    P. J. Hobson
    J. Vovrosh
    B. Stray
    M. Packer
    J. Winch
    N. Holmes
    F. Hayati
    K. McGovern
    R. Bowtell
    M. J. Brookes
    K. Bongs
    T. M. Fromhold
    M. Holynski
    Scientific Reports, 12
  • [13] Bespoke magnetic field design for a magnetically shielded cold atom interferometer
    Hobson, P. J.
    Vovrosh, J.
    Stray, B.
    Packer, M.
    Winch, J.
    Holmes, N.
    Hayati, F.
    McGovern, K.
    Bowtell, R.
    Brookes, M. J.
    Bongs, K.
    Fromhold, T. M.
    Holynski, M.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [14] Conditions of Exciting Coils Used in Evaluation of Shielding Factor of Magnetically Shielded Rooms for Uniform Magnetic Field
    Odawara, Shunya
    Muramatsu, Kazuhiro
    Gao, Yanhui
    Komori, Shogo
    Yamazaki, Keita
    Shinnoh, Toshifumi
    Yamaguchi, Takao
    Sakakibara, Mitsuru
    Shimokawa, Masao
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (10) : 4274 - 4277
  • [15] Design of uniform field coils coupled with a magnetic shield cylinder?
    Huang, Binyue
    Cao, Qian
    Chen, Zhengyu
    Wang, Yuhao
    Yue, Ziqian
    Zhai, Yueyang
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2023, 583
  • [16] Design and Optimization of Biplanar Coils for Active Magnetic Compensation System Inside the MINI-Magnetically Shielded Room
    Tian, Kangqi
    Zhang, Xu
    Shi, Minxia
    Yang, Jianzhi
    Cao, Fuzhi
    Wang, Fulong
    Shi, Ziyang
    Wang, Kun
    Zheng, Shiqiang
    Liu, Gang
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2025, 72 (01) : 1065 - 1075
  • [17] Non-uniform dynamic magnetic field compensation for a lightweight magnetically shielded room based on distributed differential coils
    Zhao, Jiye
    Liu, Jiawen
    Zhou, Jiqiang
    Zhang, Lu
    Sun, Jinji
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2025, 58 (02)
  • [18] Design of Highly Uniform Radial Coils Considering the Coupling Effect of Magnetic Shielding Cylinder
    Wang, Weiqian
    Zhou, Xiangyang
    Zhao, Fengwen
    Xie, Xiaoxuan
    Zhou, Weiyong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [19] Jeans Instability of the Self-Gravitating Viscoelastic Ferromagnetic Cylinder with Axial Nonuniform Rotation and Magnetic Field
    Joginder Singh Dhiman
    Rajni Sharma
    Journal of Astrophysics and Astronomy, 2017, 38
  • [20] Jeans Instability of the Self-Gravitating Viscoelastic Ferromagnetic Cylinder with Axial Nonuniform Rotation and Magnetic Field
    Dhiman, Joginder Singh
    Sharma, Rajni
    JOURNAL OF ASTROPHYSICS AND ASTRONOMY, 2017, 38 (04)