Comprehensive, Quantitative Analysis of SRM 1950: the NIST Human Plasma Reference Material

被引:1
|
作者
Mandal, Rupasri [1 ]
Zheng, Jiamin [1 ]
Zhang, Lun [1 ]
Oler, Eponine [1 ]
Levatte, Marcia A. [1 ]
Berjanskii, Mark [1 ]
Lipfert, Matthias [1 ]
Han, Jun [2 ,3 ]
Borchers, Christoph H. [4 ]
Wishart, David S. [1 ]
机构
[1] Univ Alberta, Dept Biol Sci, Edmonton, AB T6G 2E9, Canada
[2] Univ Victoria, Dept Biochem & Microbiol, Victoria, BC V8W 2Y2, Canada
[3] UVic Genome BC Prote Ctr, Victoria, BC V8Z 7X8, Canada
[4] McGill Univ, Jewish Gen Hosp, Lady Davis Inst, Div Expt Med, Montreal, PQ H3T 1E4, Canada
基金
加拿大创新基金会;
关键词
STANDARD REFERENCE MATERIAL; LIPID EXTRACTION; LC-MS/MS; METABOLOMICS; DISCOVERY; NMR;
D O I
10.1021/acs.analchem.4c05018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many analytical methods have been developed for performing targeted metabolomics. By combining multiple analytical techniques, comprehensive coverage of the metabolome can be achieved. We combined multiple analytical techniques to comprehensively and quantitatively characterize the widely studied NIST human plasma reference material, SRM 1950. Our goal was to provide a large, well-validated list of confident metabolite concentration values (i.e., benchmarks) to assist the metabolomics community in its calibration and comparison efforts. We used four analytical platforms: high-resolution NMR spectroscopy, direct injection tandem MS (DI-MS/MS), liquid chromatography tandem MS (LC-MS/MS), and inductively coupled plasma MS (ICP-MS). Eight validated analytical assays were run, yielding accurate quantitative measurements for 728 unique metabolites or metabolite species. Through computer-aided literature mining, we identified another 330 unique metabolites previously quantified in SRM 1950. We compared NIST-certified values along with literature-derived concentrations/ranges to the metabolite concentrations measured by our four platforms and eight assays. From these assays/platforms, we generated a list of high-confidence concentration values of 1058 metabolites or metabolite species in SRM 1950 including data for 60 amino acids/related compounds, 48 bile acids, 72 amines/sugars/alcohols, 21 metals, 8 catecholamines, 11 vitamins, 92 organic acids, 40 fatty acids/steroids/nucleobases/indole derivatives, 5 polyfluorinated compounds, 7 carotenoids, 39 acylcarnitines, 76 oxylipins, 13 sterols, and 566 lipids/lipid species. This data set represents the most complete quantitative characterization of SRM 1950. An online database (SRM1950-DB) containing 1058 plasma metabolites/metabolite species in SRM 1950, their structures, HMDB IDs, mass, chemical class, concentrations, references, and reliability is freely available at https://srm1950-data.wishartlab.com.
引用
收藏
页码:667 / 675
页数:9
相关论文
共 50 条
  • [41] Influence of Spot Size on LA-ICP-MS Ablation Behavior for Synthetic Calcium Tungstate and Silicate Glass Reference Material NIST SRM 610
    Xiao, Yuting
    Yang, Jian
    Deng, Jun
    Wang, Wei
    Ke, Yuqiu
    Sun, Yijian
    ATOMIC SPECTROSCOPY, 2021, 42 (01) : 36 - 42
  • [42] Investigation of Thulium and Other Rare Earth Element Mass Fractions in NIST SRM 1632a Bituminous Coal Reference Material by Quadrupole ICP-MS
    Roth, Elliot
    Bank, Tracy L.
    Granite, Evan
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2018, 42 (02) : 263 - 269
  • [43] Extension of AOAC Official Method 996.01 to the analysis of Standard Reference Material (SRM) 1846 and infant formulas
    Satchithanandam, S
    Fritsche, J
    Rader, JI
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (03) : 805 - 813
  • [44] Potentials of on-line scanning electron microscope performance analysis using NIST Reference Material 8091
    Postek, MT
    Vladar, AE
    Zhang, NF
    Larrabee, RD
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XIV, 2000, 3998 : 28 - 37
  • [45] NEUTRON-ACTIVATION ANALYSIS OF THE NIST BOVINE SERUM STANDARD REFERENCE MATERIAL USING CHEMICAL SEPARATIONS
    GREENBERG, RR
    ZEISLER, R
    KINGSTON, HM
    SULLIVAN, TM
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (06): : 652 - 656
  • [46] Rietveld quantitative X-ray diffraction analysis of NIST fly ash standard reference materials
    Winburn, RS
    Grier, DG
    McCarthy, GJ
    Peterson, RB
    POWDER DIFFRACTION, 2000, 15 (03) : 163 - 172
  • [47] Development of Standard Reference Material (SRM) 2973 Vitamin D Metabolites in Frozen Human Serum (High Level)
    Tai, Susan S. -C.
    Nelson, Michael A.
    Bedner, Mary
    Lang, Brian E.
    Phinney, Karen W.
    Sander, Lane C.
    Yen, James H.
    Betz, Joseph M.
    Sempos, Christopher T.
    Wise, Stephen A.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (05) : 1294 - 1303
  • [48] Development of standard reference material (SRM) 2973 Vitamin D Metabolites in frozen human serum (High Level)
    Tai, Susan S.-C.
    Nelson, Michael A.
    Bedner, Mary
    Lang, Brian E.
    Phinney, Karen W.
    Sander, Lane C.
    Yen, James H.
    Betz, Joseph M.
    Sempos, Christopher T.
    Wise, Stephen A.
    Journal of AOAC International, 2017, 100 (05): : 1294 - 1303
  • [49] Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements
    Zarr, Robert R.
    Heckert, N. Alan
    Leigh, Stefan D.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2014, 119 : 296 - 370
  • [50] Standard Reference Material (SRM) 2378 fatty acids in frozen human serum. Certification of a clinical SRM based on endogenous supplementation of polyunsaturated fatty acids
    Bruce A. Benner
    Michele M. Schantz
    Carissa D. Powers
    Rosemary L. Schleicher
    Johanna E. Camara
    Katherine E. Sharpless
    James H. Yen
    Lorna T. Sniegoski
    Analytical and Bioanalytical Chemistry, 2018, 410 : 2321 - 2329