A Novel Simulation Model of Shielding Performance Based on the Anisotropic Magnetic Property of Magnetic Shields

被引:0
|
作者
Ma, Yuzheng [1 ,2 ]
Shi, Minxia [1 ,2 ,3 ]
Zhang, Leran [1 ,2 ]
Li, Teng [1 ,2 ]
Ling, Xuechen [1 ,2 ]
Yuan, Shuai [1 ,2 ]
Wang, Hanxing [1 ,2 ]
Gao, Yi [1 ,2 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Beihang Univ, Hangzhou Innovat Inst, Zhejiang Prov Key Lab Ultraweak Magnet Field Space, Hangzhou 310051, Peoples R China
[3] Hefei Natl Lab, Hefei 230088, Peoples R China
基金
中国国家自然科学基金;
关键词
2D-SST measuring device; anisotropic magnetic properties; magnetic field simulation; shielding factor (SF); performance calculation model; RELAXATION;
D O I
10.3390/ma17235906
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
To achieve a near-zero magnetic field environment, the use of permalloy sheets with high-performance magnetic properties is essential. However, mainstream welding processes for magnetically shielded rooms (MSRs), such as argon arc welding and laser welding, can degrade the magnetic properties of the material. Additionally, neglecting the anisotropy of permalloy sheets can introduce unpredictable errors in the evaluation of MSR performance. To address this issue, this paper proposes a modified model for calculating the shielding factor (SF) of MSRs that incorporates the anisotropic magnetic characteristics of permalloy sheets. These characteristics were measured using a two-dimensional single sheet tester (2D-SST). A high-precision measurement system was developed, comprising a 2D-SST (to generate two-dimensional magnetic fields and sense the induced B and H signals) and a control system (to apply in-phase 2D excitation signals and amplify, filter, and record the B and H data). Hysteresis loops were tested at low frequencies (0.1-9 Hz) and under different magnetization states (0.1-0.6 T) in two orientations-parallel and perpendicular to the annealing magnetic field-to verify anisotropy under varying conditions. Initial permeability, near-saturation magnetization, and basic magnetization curves (BM curves) were measured across different directions to provide parameters for simulations and theoretical calculations. Based on these measurements and finite element simulations, a mathematical model was developed to adjust the empirical coefficient lambda used in theoretical SF calculations. The results revealed that the ratio of empirical coefficients in different directions is inversely proportional to the ratio of magnetic permeability in the corresponding directions. A verification group was established to compare the original model and the modified model. The mean squared error (MSE) between the original model and the finite element simulation was 49.97, while the MSE between the improved model and the finite element simulation was reduced to 0.13. This indicates a substantial improvement in the computational accuracy of the modified model.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Effect of Discontinuities and Penetrations on the Shielding Efficacy of High Temperature Superconducting Magnetic Shields
    Hatwar, R.
    Kvitkovic, J.
    Herman, C.
    Pamidi, S.
    ADVANCES IN CRYOGENIC ENGINEERING - MATERIALS: PROCEEDINGS OF THE INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE (ICMC) 2015, 2015, 102
  • [32] SHIELDING OF ASYNCHRONOUS MAGNETIC-FIELDS IN THE SUPERCONDUCTING SYNCHRONOUS GENERATOR WITH ELECTROMAGNETIC SHIELDS
    MUTA, I
    MUKAI, E
    YAGI, M
    ELECTRICAL ENGINEERING IN JAPAN, 1978, 98 (05) : 92 - 99
  • [33] Improvement of Magnetic Shielding for Transformers Based on the Magnetic Flux Characteristics at Shielding Ends
    Wang, Tao
    Yuan, Weiying
    Fu, Dajin
    Yuan, Jiansheng
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (01)
  • [34] Magnetic shielding property of high-Tc superconductor
    Tsukamoto, Keizou
    Ishii, Mamoru
    Shimojima, Hiromasa
    Yamagishi, Chitake
    Takata, Masasuke
    Yamashita, Tsutomu
    Funtai Oyobi Fummatsu Yakin/Journal of the Japan Society of Powder and Powder Metallurgy, 1991, 38 (02): : 259 - 262
  • [35] Experimental Study on the Magnetic Field Shielding Property of CFRP
    Si, Qing
    Huang, Zhengyu
    Shi, Lihua
    Zhou, Yinghui
    Du, Mingxin
    Jiang, Wenwen
    2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 488 - 490
  • [36] Dependence of magnetic shielding property on critical current density
    Ishii, Mamoru
    Tsukamoto, Keizou
    Shimojima, Hiromasa
    Yamagishi, Chitake
    Takata, Masasuke
    Yamashita, Tsutomu
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1992, 31 (5 A): : 1310 - 1312
  • [37] Magnetic-field simulation for shielding from high magnetic fields
    Uetake, H
    Hirota, N
    Ikezoe, Y
    Kitazawa, K
    Miyoshi, K
    JOURNAL OF APPLIED PHYSICS, 2002, 91 (10) : 6991 - 6993
  • [38] Discussion on anisotropic magnetic shielding effectiveness of shielded package analyzed by magnetic circuit calculation
    Yamada K.
    Fuji Y.
    Hara M.
    Journal of the Magnetics Society of Japan, 2020, 44 (01) : 15 - 20
  • [39] Magnetic-field simulation for shielding from high magnetic fields
    Uetake, H., 1600, American Institute of Physics Inc. (91):
  • [40] A Study of Enclosed Magnetic Shielding Room By Simulation
    Xu, Zihan
    Zhang, Zhidan
    Wu, Bao
    Wang, Hai
    Kong, Xiangyan
    Wang, Meiling
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)