Late gadolinium enhancement cardiovascular magnetic resonance with generative artificial intelligence

被引:1
|
作者
Demirel, Omer Burak [1 ,2 ]
Ghanbari, Fahime [1 ,2 ]
Hoeger, Christopher W. [1 ,2 ]
Tsao, Connie W. [1 ,2 ]
Carty, Adele [1 ,2 ]
Ngo, Long H. [1 ,2 ]
Pierce, Patrick [1 ,2 ]
Johnson, Scott [1 ,2 ]
Arcand, Kathryn [1 ,2 ]
Street, Jordan [1 ,2 ]
Rodriguez, Jennifer [1 ,2 ]
Wallace, Tess E. [1 ,2 ,4 ]
Chow, Kelvin [5 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Dept Med, Cardiovasc Div, BOSTON, MA 02115 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA USA
[4] Siemens Med Solut USA Inc, Boston, MA USA
[5] Siemens Healthcare Ltd, Cardiovasc MR R&D, Calgary, AB, Canada
基金
美国国家卫生研究院;
关键词
Late gadolinium enhancement; Highly accelerated; Deep learning; INVERSION-RECOVERY; RECONSTRUCTION; MRI;
D O I
10.1016/j.jocmr.2024.101127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
<bold>Background: </bold>Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging enables imaging of scar/fibrosis and is a cornerstone of most CMR imaging protocols. CMR imaging can benefit from image acceleration; however, image acceleration in LGE remains challenging due to its limited signal-to-noise ratio. In this study, we sought to evaluate a rapid two-dimensional (2D) LGE imaging protocol using a generative artificial intelligence (AI) algorithm with inline reconstruction. <bold>Methods: </bold>A generative AI-based image enhancement was used to improve the sharpness of 2D LGE images acquired with low spatial resolution in the phase-encode direction. The generative AI model is an image enhancement technique built on the enhanced super-resolution generative adversarial network. The model was trained using balanced steady-state free-precession cine images, readily used for LGE without additional training. The model was implemented inline, allowing the reconstruction of images on the scanner console. We prospectively enrolled 100 patients (55 +/- 14 years, 72 males) referred for clinical CMR at 3T. We collected three sets of LGE images in each subject, with in-plane spatial resolutions of 1.5 x 1.5-3-6 mm(2). The generative AI model enhanced in-plane resolution to 1.5 x 1.5 mm(2) from the low-resolution counterparts. Images were compared using a blur metric, quantifying the perceived image sharpness (0 = sharpest, 1 = blurriest). LGE image sharpness (using a 5-point scale) was assessed by three independent readers. <bold>Results: </bold>The scan times for the three imaging sets were 15 +/- 3, 9 +/- 2, and 6 +/- 1 s, with inline generative AI-based images reconstructed time of similar to 37 ms. The generative AI-based model improved visual image sharpness, resulting in lower blur metric compared to low-resolution counterparts (AI-enhanced from 1.5 x 3 mm(2) resolution: 0.3 +/- 0.03 vs 0.35 +/- 0.03, P < 0.01). Meanwhile, AI-enhanced images from 1.5 x 3 mm(2) resolution and original LGE images showed similar blur metric (0.30 +/- 0.03 vs 0.31 +/- 0.03, P = 1.0) Additionally, there was an overall 18% improvement in image sharpness between AI-enhanced images from 1.5 x 3 mm(2) resolution and original LGE images in the subjective blurriness score (P < 0.01). <bold>Conclusion: </bold>The generative AI-based model enhances the image quality of 2D LGE images while reducing the scan time and preserving imaging sharpness. Further evaluation in a large cohort is needed to assess the clinical utility of AI-enhanced LGE images for scar evaluation, as this proof-of-concept study does not provide evidence of an impact on diagnosis.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Late gadolinium enhancement cardiovascular magnetic resonance in genotyped hypertrophic cardiomyopathy with normal phenotype
    Strijack, Bradford
    Ariyarajah, Vignendra
    Soni, Reeni
    Jassal, Davinder S.
    Greenberg, Cheryl R.
    McGregor, Robert
    Morris, Andrew
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [22] Late gadolinium enhancement by cardiovascular magnetic resonance heralds an adverse prognosis in nonischemic cardiomyopathy
    Wu, Katherine C.
    Weiss, Robert G.
    Thiemann, David R.
    Kitagawa, Kakuya
    Schmidt, Andre
    Dalal, Darshan
    Lai, Shenghan
    Bluemke, David A.
    Gerstenblith, Gary
    Marban, Eduardo
    Tomaselli, Gordon F.
    Lima, Joao A. C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (25) : 2414 - 2421
  • [23] Cardiac resynchronization therapy guided by late gadolinium-enhancement cardiovascular magnetic resonance
    Francisco Leyva
    Paul WX Foley
    Shajil Chalil
    Karim Ratib
    Russell EA Smith
    Frits Prinzen
    Angelo Auricchio
    Journal of Cardiovascular Magnetic Resonance, 13
  • [24] Artificial Intelligence in Cardiovascular Magnetic Resonance Imaging
    Castellaccio, A.
    Arostegui, N. Almeida
    Jimenez, M. Palomo
    Tapia, D. Quinones
    Zurita, M. Bret
    Galvan, E. Vano
    RADIOLOGIA, 2025, 67 (02): : 239 - 247
  • [25] Low prevalence of fibrosis in thalassemia major assessed by late gadolinium enhancement cardiovascular magnetic resonance
    Paul Kirk
    John Paul Carpenter
    Mark A Tanner
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 13
  • [26] Prognostic value of presence and pattern of late gadolinium enhancement by cardiovascular magnetic resonance in nonischemic cardiomyopathy
    Valle, A.
    Estornell, J.
    Corbi, M.
    Pirola, A.
    Martinez, N.
    Laynez, A.
    Rodriguez, C. J.
    Federico, P.
    Paya, R.
    Ridocci Soriano, F.
    EUROPEAN HEART JOURNAL, 2009, 30 : 743 - 743
  • [27] Echocardiography and cardiovascular magnetic resonance based evaluation of myocardial strain and relationship with late gadolinium enhancement
    Erley, Jennifer
    Genovese, Davide
    Tapaskar, Natalie
    Alvi, Nazia
    Rashedi, Nina
    Besser, Stephanie A.
    Kawaji, Keigo
    Goyal, Neha
    Kelle, Sebastian
    Lang, Roberto M.
    Mor-Avi, Victor
    Patel, Amit R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
  • [28] Prevalence and pattern of cardiovascular magnetic resonance late gadolinium enhancement in highly trained endurance athletes
    B. Domenech-Ximenos
    M. Sanz-de la Garza
    S. Prat-González
    A. Sepúlveda-Martínez
    F. Crispi
    K. Duran-Fernandez
    R. J. Perea
    B. Bijnens
    M. Sitges
    Journal of Cardiovascular Magnetic Resonance, 22
  • [29] Prevalence and pattern of cardiovascular magnetic resonance late gadolinium enhancement in highly trained endurance athletes
    Domenech-Ximenos, B.
    Sanz-de la Garza, M.
    Prat-Gonzalez, S.
    Sepulveda-Martinez, A.
    Crispi, F.
    Duran-Fernandez, K.
    Perea, R. J.
    Bijnens, B.
    Sitges, M.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [30] Echocardiography and cardiovascular magnetic resonance based evaluation of myocardial strain and relationship with late gadolinium enhancement
    Jennifer Erley
    Davide Genovese
    Natalie Tapaskar
    Nazia Alvi
    Nina Rashedi
    Stephanie A. Besser
    Keigo Kawaji
    Neha Goyal
    Sebastian Kelle
    Roberto M. Lang
    Victor Mor-Avi
    Amit R. Patel
    Journal of Cardiovascular Magnetic Resonance, 21