Innovative 3D-printed porous tantalum cage with non-window design to accelerate spinal fusion: A proof-of-concept study

被引:0
|
作者
Liang, Hang [1 ,2 ]
Tu, Jingyao [3 ]
Wang, Bingjin [1 ]
Song, Yu [1 ]
Wang, Kun [1 ]
Zhao, Kangcheng [1 ]
Hua, Wenbin [1 ]
Li, Shuai [1 ]
Tan, Lei [1 ]
Feng, Xiaobo [1 ,2 ]
Yang, Cao [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Orthoped, Wuhan, Peoples R China
[2] Shenzhen Huazhong Univ, Sci & Technol Res Inst, Shenzhen, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Oncol, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
Porous Ta cage; Non-window design; 3D printing; Osseointegration; Spine fusion; LUMBAR INTERBODY FUSION; IMPLANTS; BIOMATERIALS; FABRICATION; SCAFFOLDS;
D O I
10.1016/j.mtbio.2025.101576
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An interbody fusion cage is crucial in spine fusion procedures, serving to restore physiological vertebral alignment and reestablish spinal stability. However, conventional fusion cages often face challenges related to insufficient osteointegration and the requirement for substantial bone grafting, which may result in incomplete fusion and prolonged recovery periods. In this study, we harnessed the osteointegration advantages of tantalum (Ta), in conjunction with advanced 3D printing technology, to develop a novel non-window-type Ta cage. The mechanical and biological characteristics of the cage were comprehensively evaluated through mechanical testing, in vitro cellular assays, and in vivo sheep anterior cervical discectomy and fusion models. The results indicated that the 3D-printed porous tantalum (3D-pTa) cage, with mechanical properties analogous to those of trabecular bone, exhibited superior bone ingrowth and osseointegration performance, achieving excellent intervertebral fusion without the need for bone grafting, thereby enhancing cervical vertebra stability. Moreover, we performed a pilot clinical trial to assess the performance of non-window-type 3D-pTa cages in single-level posterior lumbar interbody fusion. The results demonstrated that 3D-pTa achieved favorable clinical outcomes up to the 12-month follow-up period. These results highlight the significant clinical potential of the 3D-pTa cage for spinal fusion applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] 3D-Printed Soft Structure of Polyurethane and Magnetorheological Fluid: A Proof-of-Concept Investigation of its Stiffness Tunability
    Hong, Seong-Woo
    Yoon, Ji-Young
    Kim, Seong-Hwan
    Lee, Sun-Kon
    Kim, Yong-Rae
    Park, Yu-Jin
    Kim, Gi-Woo
    Choi, Seung-Bok
    MICROMACHINES, 2019, 10 (10)
  • [12] In Vitro and in Vivo Study of 3D-Printed Porous Tantalum Scaffolds for Repairing Bone Defects
    Guo, Yu
    Xie, Kai
    Jiang, Wenbo
    Wang, Lei
    Li, Guoyuan
    Zhao, Shuang
    Wu, Wen
    Hao, Yongqiang
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2019, 5 (02) : 1123 - 1133
  • [13] Computer-aided designed 3D-printed polymeric scaffolds for personalized reconstruction of maxillary and mandibular defects: a proof-of-concept study
    Davide Mattavelli
    Vincenzo Verzeletti
    Alberto Deganello
    Antonio Fiorentino
    Tommaso Gualtieri
    Marco Ferrari
    Stefano Taboni
    William Anfuso
    Marco Ravanelli
    Vittorio Rampinelli
    Alberto Grammatica
    Barbara Buffoli
    Roberto Maroldi
    Ceretti Elisabetta
    Rita Rezzani
    Piero Nicolai
    Cesare Piazza
    European Archives of Oto-Rhino-Laryngology, 2024, 281 : 1493 - 1503
  • [14] Computer-aided designed 3D-printed polymeric scaffolds for personalized reconstruction of maxillary and mandibular defects: a proof-of-concept study
    Mattavelli, Davide
    Verzeletti, Vincenzo
    Deganello, Alberto
    Fiorentino, Antonio
    Gualtieri, Tommaso
    Ferrari, Marco
    Taboni, Stefano
    Anfuso, William
    Ravanelli, Marco
    Rampinelli, Vittorio
    Grammatica, Alberto
    Buffoli, Barbara
    Maroldi, Roberto
    Elisabetta, Ceretti
    Rezzani, Rita
    Nicolai, Piero
    Piazza, Cesare
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2024, 281 (3) : 1493 - 1503
  • [15] A novel human peristalsis-inspired 3D-printed gastroduodenal simulator to evaluate intragastric/duodenal metabolic devices: a proof-of-concept study
    Kwon, Jinhee
    Bang, Chang Seok
    Kim, Sung Ock
    Park, Do Hyun
    JOURNAL OF TRANSLATIONAL MEDICINE, 2022, 20 (01)
  • [16] A novel human peristalsis-inspired 3D-printed gastroduodenal simulator to evaluate intragastric/duodenal metabolic devices: a proof-of-concept study
    Jinhee Kwon
    Chang Seok Bang
    Sung Ock Kim
    Do Hyun Park
    Journal of Translational Medicine, 20
  • [17] Evaluation of biological performance of 3D printed trabecular porous tantalum spine fusion cage in large animal models
    Zhang, Yiming
    Yang, Jingzhou
    Wan, Wentao
    Zhao, Qingqian
    Di, Mingyuan
    Zhang, Dachen
    Liu, Gang
    Chen, Chao
    Sun, Xun
    Zhang, Wei
    Bian, Hanming
    Liu, Yang
    Tian, Ye
    Xue, Lu
    Dou, Yiming
    Wang, Zheng
    Li, Qiulin
    Yang, Qiang
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2025, 50 : 185 - 195
  • [18] Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage
    Segi, Naoki
    Nakashima, Hiroaki
    Shinjo, Ryuichi
    Kagami, Yujiro
    Machino, Masaaki
    Ito, Sadayuki
    Ouchida, Jun
    Morishita, Kazuaki
    Oishi, Ryotaro
    Yamauchi, Ippei
    Imagama, Shiro
    MEDICINA-LITHUANIA, 2023, 59 (02):
  • [19] Proof-of-concept demonstration of a Total Internal Reflection based module for fluorescence and absorbance detection using a 3D-printed syringe pump
    Verschooten, Tom
    Ottevaere, Heidi
    Vervaeke, Michael
    Van Erps, Jurgen
    Thienpont, Hugo
    MICRO-OPTICS 2014, 2014, 9130
  • [20] Comparison of Fusion, Subsidence, and Clinical Results Between 3D-Printed Porous Titanium Cage and Polyetheretherketone Cage in Posterior Lumbar Interbody Fusion: A Minimum of 2 Years Follow-Up
    Yang, Jae Jun
    Kim, Dong -Min
    Park, Sehan
    WORLD NEUROSURGERY, 2023, 177 : E732 - E741