Comparison of Clinical Performance of I-gel and Fastrach Laryngeal Mask Airway as an Intubating Device in Adults: A Systematic Review and Meta-Analysis

被引:0
|
作者
Assis, Maria Luisa Machado [1 ]
Zasso, Fabricio Batistella [2 ]
Chavez, Matheus Pedrotti [3 ]
Toledo, Eduardo Cirne [4 ]
Motta, Gabriel [5 ]
Moraes, Leonardo Duarte [6 ]
Pasqualotto, Eric [3 ]
Ferreira, Rafael Oliva Morgado
Siddiqui, Naveed [2 ]
You-Ten, Kong Eric [2 ]
机构
[1] Mayo Clin, Dept Anesthesia, Jacksonville, FL USA
[2] Univ Toronto, Mt Sinai Hosp, Dept Anesthesiol & Pain Management, 7-405,600 Uni Ave, Toronto, ON M5G 1X5, Canada
[3] Univ Fed Santa Catarina, Dept Med, Florianopolis, Brazil
[4] Tufts Med Ctr, Dept Anesthesia & Intens Care, BOSTON, MA USA
[5] Univ Fed Estado Rio de Janeiro, Dept Med, Rio de Janeiro, Brazil
[6] Hosp Clin, Dept Anesthesia, Fac Med Ribeirao Preto, Ribeirao Preto, Brazil
来源
ANESTHESIA AND ANALGESIA | 2025年 / 140卷 / 02期
关键词
BLIND TRACHEAL INTUBATION; SINGLE-USE ILMA(TM); ANESTHETIZED PATIENTS; SUPRAGLOTTIC AIRWAY; LMA FASTRACH(TM); I-GEL(TM); TUBE; GUIDELINES; TRIAL;
D O I
10.1213/ANE.0000000000007000
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: The supraglottic airway device (SGD) was introduced as a breakthrough in airway management. The Fastrach emerged as the first commercially available intubating SGD, drawing extensive investigation. I-gel is a more recent device that has gained popularity, can be used as an intubating SGD, and replaced Fastrach in many institutions. However, there is uncertainty regarding the comparison between these devices in terms of efficacy for intubation and ventilation, and safety in an airway rescue situation. METHODS: PubMed, EMBASE, Scopus, and Cochrane databases were searched for randomized controlled trials (RCTs) comparing I-gel and Fastrach SGD in adult patients undergoing intubation. The primary outcome was the first-pass success rate for tracheal intubation. Secondary outcomes were tracheal intubation time, SGD insertion time and success, and complications. We computed risk ratios (RRs) to assess binary end points and weighted mean differences (WMDs) for continuous outcomes, with corresponding 95% confidence intervals (CIs) for the primary outcome and its subgroup analysis (P < .05 was considered statistically significant) and 99% CI after Bonferroni correction for the secondary outcomes (P < .01 was considered statistically significant). RESULTS: This study included a total of 14 RCTs encompassing 1340 patients. The results indicated a significant difference in the first-pass success rate favoring Fastrach (RR, 0.81; 95% CI, 0.67-0.98; P = .03; I-2 = 91%). In the subgroup analysis, when a flexible scope was utilized through I-gel, providers achieved a better tracheal intubation first-pass success rate (RR, 1.05; 95% CI, 1.01-1.11; P = .03; I-2 = 0%), compared with the Fastrach. Overall intubation success rates (RR, 0.92; 99% CI, 0.82-1.04; P = .08, I-2 = 92%) and time (WMD - 1.03 seconds; 99% CI, -4.75 to 2.69; P = .48; I-2 = 84%) showed no significant difference irrespective of the device used. There was no significant difference regarding device insertion time by the providers (WMD -6.48 seconds; 99% CI, -13.23 to 0.27; P = .01; I2 = 98%). Success rates of the providers' initial SGD insertion and complications such as sore throat (RR, 1.01; 99% CI, 0.65-1.57; P = .95, I-2 = 33%) and blood presence post-SGD removal (RR, 0.89; 99% CI, 0.42-1.86; P = .68, I-2 = 0%) showed no significant difference. CONCLUSIONS: Based on our findings, a higher first-pass success rate was observed with the use of Fastrach when compared to I-gel. However, the use of I-gel might result in a better intubation success rate with the flexible scope-guided intubation. There are no significant differences in performance in terms of the success rate for intubation overall, time for device insertion, or time to intubation or complications regardless of the device used.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [31] Comparing performance of ProSeal laryngeal mask airway and I-gel in anesthetized adult patients
    Zhang, Jia-Qiang
    Meng, Fan-Min
    Xue, Fu-Shan
    Li, Rui-Ping
    SAUDI MEDICAL JOURNAL, 2015, 36 (09) : 1130 - 1130
  • [32] Evaluating the Clinical Performance and Upper Airway Morbidity of I-Gel and its Comparison with Proseal Laryngeal Mask Airway-A Randomised Controlled Trial
    Asha, H. L.
    Nagaraj, M. C.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (04) : UC1 - UC5
  • [33] Evaluation of i-gel™ airway in children: a meta-analysis
    Maitra, Souvik
    Baidya, Dalim K.
    Bhattacharjee, Sulagna
    Khanna, Puneet
    PEDIATRIC ANESTHESIA, 2014, 24 (10) : 1072 - 1079
  • [34] A comparison of fibreoptic-guided tracheal intubation through the Ambu®Aura-i™, the intubating laryngeal mask airway and the i-gel™: a manikin study
    de Lloyd, L. J.
    Subash, F.
    Wilkes, A. R.
    Hodzovic, I.
    ANAESTHESIA, 2015, 70 (05) : 591 - 597
  • [35] Comparison between I-Gel and Classic Laryngeal Mask Airway for Airway Management of Patients with Anticipated Difficult Airway: A Randomised Clinical Trial
    Raman, Rajesh
    Gautam, Shefali
    Sonkar, Suraj
    Prabha, Rati
    Alam, Sharif
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : UC10 - UC13
  • [36] Clinical Comparison of I-gel and Laryngeal Mask Airway-Supreme Airway Devices During General Anaesthesia in the Paediatric Population
    Aggarwal, Manish
    Yadav, Rahul
    Singh, Shalendra
    Bansal, Deepali
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (03) : 244 - 249
  • [37] Comparison of endotracheal intubation, laryngeal mask airway, and I-gel in children undergoing strabismus surgery
    Allahyari, Elaheh
    Azimi, Ali
    Zarei, Hamed
    Bamdad, Shahram
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2021, 26 (01):
  • [38] Are nurses able to perform blind intubation? Randomized comparison of I-gel and laryngeal mask airway
    Ladny, Jerzy R.
    Bielski, Karol
    Szarpak, Lukasz
    Cieciel, Michal
    Konski, Roman
    Smereka, Jacek
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (05): : 786 - 787
  • [39] Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin
    de Lloyd, L.
    Hodzovic, I.
    Voisey, S.
    Wilkes, A. R.
    Latto, I. P.
    ANAESTHESIA, 2010, 65 (01) : 36 - 43
  • [40] A randomized comparison of the i-gel™ with the self-pressurized air-Q™ intubating laryngeal airway in children
    Kim, Min-Soo
    Lee, Jae Hoon
    Han, Sang Won
    Im, Young Jae
    Kang, Hyo Jong
    Lee, Jeong-Rim
    PEDIATRIC ANESTHESIA, 2015, 25 (04) : 405 - 412